Graco 24B596, 24B591 Power UP Setup, Power Up can be programmed one of four ways

Page 22

Setup

4.Use the RIGHT arrow to move the cursor to the next field. Repeat step 3.

NOTE: The maximum number of Counts you can setup in this field is 9999.

5.Use the Arrow keys to move the cursor over the TIME field.

6.Press ENTER.

NOTE: Time is displayed in HH:MM:SS.

7.Use the UP/DOWN arrows to move up and down through the numbers 0-9 until the first number in the PUMP OFF time is displayed in the field.

8.Use the RIGHT arrow to move the cursor to the next field. Repeat step 7.

9.Repeat steps 7 and 8 until the desired time is dis- played.

10.Press ENTER.

11.Use the Arrow keys to move the cursor over the TIMEOUT pull-down menu.

FIG. 33

12.Press ENTER.

13.When time expires:

Select FAULT if an alarm should occur.

Select RUN if unit should enter PUMP ON.

14.Press ENTER.

15.Press RESET. The Main Screen, page 18 displays.

NOTE: If Count or Both is selected, the Count Icon dis- plays in the upper right corner of the screen.

POWER UP Setup

FIG. 34

1.Use the UP/DOWN Arrow keys to move the cursor over POWER UP.

2.Press ENTER to display the POWER UP setup screen.

Power Up can be programmed one of four ways:

First: At Power Up, the normal lube cycle that was in process when power was removed, is resumed.

FIG. 35

1.Use the Arrow keys to move the cursor over the POWER UP pull-down menu.

2.From the pull-down menu, select OFF.

3.Press ENTER.

4.Use the Arrow keys to move the cursor over the DELAY pull-down menu.

5.From the pull-down menu, select OFF.

6.Press RESET. The Main Screen, page 18 displays.

22

313855H

Image 22
Contents Important Safety Instructions GLC Lubrication ControllerElectric Shock Hazard Keypad, Display, and Icons Run Mode FunctionsComponent Identification Direction ArrowsIcons Installation Typical InstallationInstalling the Lubrication Controller GroundingSensor Wiring Configurations System Configuration and WiringSystem Configurations Modes of Operation Optional I/O Wiring DiagramsSystem Configuration Divider Valve SystemDual Line System Injector System Input Sensor Wiring System WiringSource Switch 2 or 3 Wire Type Pump on = Time Pump OFF = Time 30VDCDry Contact, shown. For other configuration, see or FIG Pump on = Cycle or Pressure Pump OFF = TimePump on = Cycle or Pressure Pump OFF = Machine Count System Wiring Options 30VDC System Wiring Options Alarm Out100/240VAC System Setup PIN Mode Enabled SetupSee Electric Connection Warning, Timer Setup System SetupPump on Setup Main ScreenPressure Setup Cycle END SetupCycle Mode Selection Pump OFF SetupTo Set the Pump OFF Option If Count is selected If Time is selectedIf Both is selected Power UP Setup Power Up can be programmed one of four waysThird At Power Up, immediately go to Pump on normal on time Pulsed Setup Pulsed Pump ScreenPIN Setup To enable PIN Code EntryQuick Cycle Setup Display SetupDisplay Backlight LOW Level Filtering Setup Quick Cycle Screen SetupLow Level Filtering Screen Setup Run Mode Screen IdentificationPump On Ended with Pressure Prelube Power UpPump On Ended with Time Pump Off Ended with Time Pump On Ended with Cycle Switch ActivationPump Off Ended with Machine Counts Alarms Screen Pump Off Ended with Machine Counts Max Time EnteredDescription Problem Solution TroubleshootingProgram Settings Modes of OperationTechnical Data IP69KDimensions Mounting Hole LayoutGraco Standard Warranty Graco Information