Troubleshooting
Troubleshooting
Description | Problem | Solution | |
|
|
| |
|
|
| |
|
| Power light off: Timer is not receiving | |
|
| power. Verify connections and verify | |
| No power supplied to solenoid | power supply. | |
Timer fails to activate solenoid |
| Power light on: Verify solenoid con- | |
| nections | ||
|
| ||
|
|
| |
| Solenoid faulty | Replace solenoid | |
|
|
| |
| Timer faulty | Replace timer | |
|
|
| |
| Low level or other alarm | Refill reservoir | |
|
|
| |
Pressure switch fails to shut down | Pressure switch incorrectly wired | Verify proper connections | |
|
| ||
Pressure switch faulty | Replace pressure switch | ||
system | |||
|
| ||
Timer faulty | Replace timer | ||
| |||
|
|
|
Program Settings
| Modes of Operation | |
Description | Maximum / Minimum and Additional Comments | |
|
| |
|
| |
TIMER Setup, page 18 | HH:MM:SS (00:00:01 - 99:59:59) | |
|
| |
PRESSURE Setup, page 19 | HH:MM:SS (00:00:01 - 99:59:59) | |
|
| |
CYCLE END Setup, page 19 | HH:MM:SS (00:00:01 - 99:59:59) | |
|
| |
CYCLE MODE Selection, page 20 | Cycles = 01 - 99 | |
|
| |
| Time, Pressure or Cycles | |
PUMP ON Setup, page 18 | Pump ON Time: HH:MM:SS (00:00:01 - 99:59:59) | |
| Cycles: 01 - 99 (only used when mode of operation = cycles) | |
|
| |
| Time, Count or Both | |
PUMP OFF Setup, page 20 | Pump OFF Time: HH:MM:SS. (00:00:01 - 99:59:59) | |
| Count: 01 - 9999 | |
|
| |
POWER UP Setup, page 22 | MM:SS (00:01 - 59:59) | |
|
| |
PULSED Output (pump), page 24 | Maximum Time OFF and Time ON: SS | |
|
| |
PIN Number Setup, page 25 | ON / OFF | |
0000 - 9999 | ||
| ||
|
| |
| Cycles = 01 - 99 | |
QUICK CYCLE SCREEN Setup, page 26 | Time ON and Time OFF: SS | |
| Execute: YES / NO | |
|
| |
| YES / NO | |
PRELUBE on Power Up, page 30 | Delay: YES / NO | |
| TIME: MM:SS (00:01 - 59:59) | |
|
|
313855H | 33 |