Panasonic WJ-MP204C manual Setup menus

Page 20

Setup menus

There are two setup menu groups depending on the communication protocol used in the system, menus for PS Data and for the Camera Communication Protocol. MODE DIP switch # 3 on the rear of the unit is set to the position of the used protocol, and it specifies what menu group is displayed on the monitor. Menu trees are shown below for two protocols.

Setup menus for PSData

Setup menus for Camera Communication

 

Protocol

COMMUNICATION

UNIT ADDRESS

BAUD RATE

DATA BIT

PARITY CHECK

STOP BIT

WAIT TIME

SYSTEM

ALARM MODE

MONITOR SPOT

MONITOR SPOT

ALARM DISPLAY

SITE ALARM

TERM. ALARM

ALARM OUTPUT

ALARM DATA

COMP/VD2/DATA

CAMERA IN

COMP

VD2

DATA

VS/VD INPUT

CAMERA CONFIG

CAMERA CONFIG

DAISY MODE

TERMINAL

COMMUNICATION

CAM ADDRESS

CAM ADDRESS

BAUD RATE

DATA BIT

PARITY CHECK

STOP BIT

WAIT TIME

DELAY TIME

XON/XOFF

SYSTEM

ALARM MODE

MONITOR SPOT

ALARM DISPLAY

SITE ALARM

TERM. ALARM

ALARM OUTPUT

ALARM DATA

COMP/VD2/DATA

CAMERA IN

COMP

VD2

DATA

VS/VD INPUT

DAISY MODE

TERMINAL

20

Image 20
Contents Operating Instructions English Version Important Safety Instructions Contents Features PrefacePrecautions Do not drop metallic parts through slotsDo not attempt to disassemble the appliance Handle the appliance with careFront View Rear View Installation Mounting in the RackMounting One WJ-MP204C with the WV-Q204/1 Mounting two WJ-MP204Cs with the WV-Q204/2Connection & Setting Basic Connection PS DataCamera Site Control SiteUnitMultiConnection PS Data Camera SiteVideo Multiplexer Connection PS Data ModeDigital Disk Recorder Connection PS Data WV-CU50Matrix Switcher Connection Camera Communication WJ-MP204CDIP Switch Setting Unit Number SettingSetting the unit number OFFAlarm/Remote Terminal Setting PS DataCamera Communication Protocol Camera IN/OUTInternal Setting RS-485 Data Port Connection PS DataInternal Diagram Line Half Duplex RS-485 Terminal Connection Camera CommunicationBasic Connection Daisy ConnectionSetup Procedures Prior to setupButtons used in the setup WJ-MP204C Setup MENUX.XX Communication SystemSetup menus Setup Menus for PS Data Communication setup PS DataSystem setup PS Data Communication Unit Address Baud RateAlarm CAM no PRE 1CH 2CH 3CH 4CH Alarm mode setupAlarm Data Cable compensation/VD2 sync/data setup VS/VD input setupCOMP/VD2/DATA Camera in 1CH Comp S VD2 on Data on Available channels 1CH, 2CH, 3CH, 4CHCommunication CAM Address Baud Rate Communication setup Camera CommunicationCamera Config CAM no 1CH 2CH 3CH 4CH System setup Camera Communication Protocol Available delay times ms OFF, 10, 20, 40Not USE Disabled CAM Address Camera 1CH 2CH 3CH 4CHAlarm Data AUTO2 Alarm Camera Selection Alarm OperationOperation Alarm Reset Alarm SuspensionManual resetting External resettingSpecifications Standard Accessories ALL ResetPanasonic Canada Inc