Panasonic WJ-MP204C manual RS-485 Terminal Connection Camera Communication, Basic Connection

Page 18

• Basic Connection

Data Multiplex Unit

System Controller

WJ-MP204C

WV-CU360C

DATA

DATA

Termination:

ON

• Daisy Connection

Termination:

ON

RS-485 Cable

Video Multiplexer

Data Multiplex Unit

System Controller

WJ-FS309 (WJ-FS316)

WJ-MP204C

WV-CU360C

DATA

DATA

DATA

Termination:

Termination:

ON

OFF

RS-485

Cable

Branch Cable

Termination:

ON

RS-485

Cable

RS-485 Terminal Connection (Camera Communication)

These terminals are connected with system devices using the Camera Communication Protocol in 4-line full duplex or 2-line half duplex mode specified with the DIP switch set- ting.

Notes:

Use a data grade, shielded and twisted cable suited to RS-485. The maximum allowable cable length is 4 000 ft (1 200m).

Termination should be made at both ends of the data line, while being open at intermediate devices.

84-line Full Duplex

WJ-MP204C

T R

G B A B A

RS485

T R

G B A B A

SYSTEM

UNIT

RS485

 

4-Line

MODE

(Full duplex)

 

Termination ON

(at the end position)

Camera communication mode

8Internal Diagram

8 2-line Half Duplex

4

WJ-MP204C

 

TB

T

R

3

G B A B

A

 

 

TA

 

 

2

RS485

 

 

 

RB

T

R

1

G B A B A

RA

SYSTEM

 

 

UNIT

 

 

RS485

 

 

2-Line

MODE

(Half duplex)

 

Termination ON

(at the end position)

Camera communication mode

18

Image 18
Contents Operating Instructions English Version Important Safety Instructions Contents Features PrefaceDo not attempt to disassemble the appliance PrecautionsDo not drop metallic parts through slots Handle the appliance with careFront View Rear View Mounting One WJ-MP204C with the WV-Q204/1 InstallationMounting in the Rack Mounting two WJ-MP204Cs with the WV-Q204/2Camera Site Connection & SettingBasic Connection PS Data Control SiteUnitMultiConnection PS Data Camera SiteVideo Multiplexer Connection PS Data ModeDigital Disk Recorder Connection PS Data WV-CU50Matrix Switcher Connection Camera Communication WJ-MP204CSetting the unit number DIP Switch SettingUnit Number Setting OFFCamera Communication Protocol Alarm/Remote Terminal SettingPS Data Camera IN/OUTInternal Setting RS-485 Data Port Connection PS DataBasic Connection Internal Diagram Line Half DuplexRS-485 Terminal Connection Camera Communication Daisy ConnectionButtons used in the setup Setup ProceduresPrior to setup WJ-MP204C Setup MENUX.XX Communication SystemSetup menus System setup PS Data Setup Menus for PS DataCommunication setup PS Data Communication Unit Address Baud RateAlarm mode setup Alarm DataAlarm CAM no PRE 1CH 2CH 3CH 4CH COMP/VD2/DATA Camera in 1CH Comp S VD2 on Data on Cable compensation/VD2 sync/data setupVS/VD input setup Available channels 1CH, 2CH, 3CH, 4CHCommunication setup Camera Communication Camera Config CAM no 1CH 2CH 3CH 4CHCommunication CAM Address Baud Rate Not USE Disabled System setup Camera Communication ProtocolAvailable delay times ms OFF, 10, 20, 40 CAM Address Camera 1CH 2CH 3CH 4CHAlarm Data AUTO2 Alarm Alarm Operation OperationCamera Selection Manual resetting Alarm ResetAlarm Suspension External resettingSpecifications Standard Accessories ALL ResetPanasonic Canada Inc