Panasonic WJ-MP204C manual System setup Camera Communication Protocol, Not USE Disabled

Page 25

8CAM ADDRESS

Camera addresses are assigned to each of the unit's cam- era input.

1.Move the cursor to CAM ADDRESS , then press SET. The CAM ADDRESS window appears.

CAM ADDRESS

CAMERA IN

ADDRESS

1CH

 

 

 

1

 

2CH

 

 

 

2

 

3CH

 

 

 

3

 

4CH

 

 

 

4

 

2.Specify a number with the [–] or [+] button. The default setting is 1.

Available numbers: 1-99, – (no assignment)

Note: This setting takes effect only when the UNIT switch is set to 0 on the front panel.

3.Repeat the above step until all camera inputs are given addresses.

4.Press ESC to return to the communication setup.

8WAIT TIME

The unit will retransmit data when there is no response dur- ing the specified wait time.

1.Move the cursor to WAIT TIME, then specify a time with the [–] or [+] button. The default setting is OFF.

Available wait times (ms): OFF, 100, 200, 400,

1 000

8DELAY TIME

This setting specifies a delay time that the unit suspends to return the response to the received command.

1.Move the cursor to DELAY TIME, then specify a time with the [–] or [+] button. The default setting is OFF.

Available delay times (ms): OFF, 10, 20, 40, 100

8X-ON/X-OFF

1.Move the cursor to XON/XOFF, then specify a mode with [–] or [+] button. The default setting is NOT USE.

USE: Data flow control is enabled during communica- tion.

NOT USE: Disabled.

2.Press ESC to return to the WJ-MP204C SETUP MENU.

8BAUD RATE

1.Move the cursor to BAUD RATE, then specify a rate with the [–] or [+] button. The default setting is 19 200.

Available rates (bit per second): 19 200, 9 600,

4 800, 2 400

8DATA BIT

1.Move the cursor to DATA BIT, then specify a bit length with the [–] or [+] button. The default setting is 8.

Available bit length: 7, 8

8PARITY

1.Move the cursor to PARITY, then specify a check mode with the [–] or [+] button. The default setting is NONE.

Available check modes: NONE, EVEN, ODD

8STOP BIT

1.Move the cursor to STOP BIT, then specify a bit length with the [–] or [+] button. The default setting is 1.

Available bit length: 1, 2

System setup

(Camera Communication Protocol)

Parameters related to alarm, sync and remote functions are set in this menu for a Camera Communication Protocol sys- tem.

The SYSTEM menu is displayed when you select it in the WJ-MP204C SETUP MENU.

SYSTEM

ALARM MODE ON

COMP/VD2/DATA

VS/VD INPUT VD

DAISY MODE ON

TERMINAL ALARM

8Alarm mode setup

In the SYSTEM menu, move the cursor to ALARM MODE.

Select ON or OFF with the [–] or [+] button, then press SET. The default setting is ON .

ON : Opens a submenu shown below.

OFF: Alarm mode is disabled.

25

Image 25
Contents Operating Instructions English Version Important Safety Instructions Contents Preface FeaturesDo not drop metallic parts through slots PrecautionsDo not attempt to disassemble the appliance Handle the appliance with careFront View Rear View Mounting in the Rack InstallationMounting One WJ-MP204C with the WV-Q204/1 Mounting two WJ-MP204Cs with the WV-Q204/2Basic Connection PS Data Connection & SettingCamera Site Control SiteCamera Site UnitMultiConnection PS DataMode Video Multiplexer Connection PS DataWV-CU50 Digital Disk Recorder Connection PS DataWJ-MP204C Matrix Switcher Connection Camera CommunicationUnit Number Setting DIP Switch SettingSetting the unit number OFFPS Data Alarm/Remote Terminal SettingCamera Communication Protocol Camera IN/OUTRS-485 Data Port Connection PS Data Internal SettingRS-485 Terminal Connection Camera Communication Internal Diagram Line Half DuplexBasic Connection Daisy ConnectionPrior to setup Setup ProceduresButtons used in the setup WJ-MP204C Setup MENUX.XX Communication SystemSetup menus Communication setup PS Data Setup Menus for PS DataSystem setup PS Data Communication Unit Address Baud RateAlarm Data Alarm mode setupAlarm CAM no PRE 1CH 2CH 3CH 4CH VS/VD input setup Cable compensation/VD2 sync/data setupCOMP/VD2/DATA Camera in 1CH Comp S VD2 on Data on Available channels 1CH, 2CH, 3CH, 4CHCamera Config CAM no 1CH 2CH 3CH 4CH Communication setup Camera CommunicationCommunication CAM Address Baud Rate Available delay times ms OFF, 10, 20, 40 System setup Camera Communication ProtocolNot USE Disabled CAM Address Camera 1CH 2CH 3CH 4CHAlarm Data AUTO2 Alarm Operation Alarm OperationCamera Selection Alarm Suspension Alarm ResetManual resetting External resettingSpecifications ALL Reset Standard AccessoriesPanasonic Canada Inc