Panasonic WJ-MP204C Communication setup Camera Communication, Communication CAM Address Baud Rate

Page 24

8Camera Configuration

The CAMERA CONFIG menu is displayed when you select it in the SYSTEM menu.

CAMERA CONFIG

CAMERA IN

CAM NO.

1CH

 

1CH

 

2CH

 

 

 

 

2CH

3CH

 

 

 

 

3CH

4CH

 

 

 

 

4CH

When more than one unit are used, each camera input is given a camera number in this menu.

1.Move the cursor to CAM NO. Select a number with the

[–]or [+] button. The default setting is that both CAM- ERA IN and CAM NO. are given the same number.

Available numbers: 1-128 and – (not connected)

2.Repeat the above step until all CAMERA IN are assigned numbers.

3.Press ESC to return to the SYSTEM menu.

SYSTEM

ALARM MODE ON

COMP/VD2/DATA

VS/VD INPUT VD

CAMERA CONFIG

DAISY MODE ON

TERMINAL ALARM

8Daisy Mode

This setup lets the unit know whether the data communica- tion line is connected in a daisy fashion.

1.Move the cursor to DAISY. Select ON or OFF with the [–] or [+] button. The default setting is ON.

ON: Set this when daisy connection is used.

OFF: Set this for other than daisy chain.

8Terminal Mode

This setup specifies the function of ALARM/REMOTE termi- nal on the rear of the unit. Input/output is specified with internal connection. Refer to page 16 for details.

1.Move the cursor to TERMINAL. Select ALARM or REMOTE with the [–] or [+] button, then press SET. The default setting is ALARM.

ALARM: Terminals are used as alarm inputs or outputs.

REMOTE: Terminals are used as remote inputs or out- puts.

Setup Menus for Camera Communication Protocol

Communication setup (Camera Communication)

Communication parameters for a Camera Communication Protocol system are set in this menu.

1.Hold down the SET button for 2 seconds to open the setup menu.

WJ-MP204C SETUP MENUX.XX

COMMUNICATION

SYSTEM

2.Move the cursor to COMMUNICATION , then press SET. The communication setup appears.

COMMUNICATION

CAM ADDRESS

 

 

 

 

 

BAUD RATE

 

 

 

 

 

19200

 

DATA BIT

 

 

 

 

 

8

 

 

 

 

PARITY CHECK

 

 

 

NONE

STOP BIT

 

 

 

 

 

1

 

 

 

 

WAIT TIME

 

 

OFF

DELAY TIME

 

 

OFF

XON/XOFF

 

NOT USE

24

Image 24
Contents Operating Instructions English Version Important Safety Instructions Contents Features PrefacePrecautions Do not drop metallic parts through slotsDo not attempt to disassemble the appliance Handle the appliance with careFront View Rear View Installation Mounting in the RackMounting One WJ-MP204C with the WV-Q204/1 Mounting two WJ-MP204Cs with the WV-Q204/2Connection & Setting Basic Connection PS DataCamera Site Control SiteUnitMultiConnection PS Data Camera SiteVideo Multiplexer Connection PS Data ModeDigital Disk Recorder Connection PS Data WV-CU50Matrix Switcher Connection Camera Communication WJ-MP204CDIP Switch Setting Unit Number SettingSetting the unit number OFFAlarm/Remote Terminal Setting PS DataCamera Communication Protocol Camera IN/OUTInternal Setting RS-485 Data Port Connection PS DataInternal Diagram Line Half Duplex RS-485 Terminal Connection Camera CommunicationBasic Connection Daisy ConnectionSetup Procedures Prior to setupButtons used in the setup WJ-MP204C Setup MENUX.XX Communication SystemSetup menus Setup Menus for PS Data Communication setup PS DataSystem setup PS Data Communication Unit Address Baud RateAlarm mode setup Alarm DataAlarm CAM no PRE 1CH 2CH 3CH 4CH Cable compensation/VD2 sync/data setup VS/VD input setupCOMP/VD2/DATA Camera in 1CH Comp S VD2 on Data on Available channels 1CH, 2CH, 3CH, 4CHCommunication setup Camera Communication Camera Config CAM no 1CH 2CH 3CH 4CHCommunication CAM Address Baud Rate System setup Camera Communication Protocol Available delay times ms OFF, 10, 20, 40Not USE Disabled CAM Address Camera 1CH 2CH 3CH 4CHAlarm Data AUTO2 Alarm Alarm Operation OperationCamera Selection Alarm Reset Alarm SuspensionManual resetting External resettingSpecifications Standard Accessories ALL ResetPanasonic Canada Inc