8Camera Configuration
The CAMERA CONFIG menu is displayed when you select it in the SYSTEM menu.
CAMERA CONFIG
CAMERA IN | CAM NO. | ||
1CH |
| 1CH |
|
2CH |
|
|
|
| 2CH | ||
3CH |
|
|
|
| 3CH | ||
4CH |
|
|
|
| 4CH |
When more than one unit are used, each camera input is given a camera number in this menu.
1.Move the cursor to CAM NO. Select a number with the
[–]or [+] button. The default setting is that both CAM- ERA IN and CAM NO. are given the same number.
Available numbers:
2.Repeat the above step until all CAMERA IN are assigned numbers.
3.Press ESC to return to the SYSTEM menu.
SYSTEM
ALARM MODE ON
COMP/VD2/DATA
VS/VD INPUT VD
CAMERA CONFIG
DAISY MODE ON
TERMINAL ALARM
8Daisy Mode
This setup lets the unit know whether the data communica- tion line is connected in a daisy fashion.
1.Move the cursor to DAISY. Select ON or OFF with the
ON: Set this when daisy connection is used.
OFF: Set this for other than daisy chain.
8Terminal Mode
This setup specifies the function of ALARM/REMOTE termi- nal on the rear of the unit. Input/output is specified with internal connection. Refer to page 16 for details.
1.Move the cursor to TERMINAL. Select ALARM or REMOTE with the
ALARM: Terminals are used as alarm inputs or outputs.
REMOTE: Terminals are used as remote inputs or out- puts.
■Setup Menus for Camera Communication Protocol
●Communication setup (Camera Communication)
Communication parameters for a Camera Communication Protocol system are set in this menu.
1.Hold down the SET button for 2 seconds to open the setup menu.
WJ-MP204C SETUP MENUX.XX
COMMUNICATION
SYSTEM
2.Move the cursor to COMMUNICATION , then press SET. The communication setup appears.
COMMUNICATION
CAM ADDRESS |
|
|
|
|
|
BAUD RATE |
|
|
|
|
|
19200 |
| ||||
DATA BIT |
|
|
|
|
|
8 |
|
|
|
| |
PARITY CHECK |
|
|
| ||
NONE | |||||
STOP BIT |
|
|
|
|
|
1 |
|
|
|
| |
WAIT TIME |
|
| |||
OFF | |||||
DELAY TIME |
|
| |||
OFF | |||||
XON/XOFF |
| ||||
NOT USE |