Panasonic WJ-MP204C manual DIP Switch Setting, Unit Number Setting, Setting the unit number, Off

Page 15

DIP Switch Setting

A 6-bit DIP switch mounted on the rear panel specifies communication mode and sync setup. The default position is marked with an asterisk * in the table below.

Bit 1 specifies the setup for synchronization. Refer to page 23 VS/VD IN and OUT for details. Bit 2 is reserved.

Bit 3 specifies the communication protocol used in the system. Bit 4 is reserved.

Bit 5 specifies the termination in the communication chain.

Bit 6 specifies RS-485 communication mode conducted via DATA port or RS-485 terminal. Set it to 4-line when PS Data is used.

OFF

1

2

 

3

 

4

5

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

 

 

 

 

 

 

SW position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit 1

 

Sync setup

 

 

 

 

 

THROUGH*

 

VS/VD

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit 2

 

Reserved

 

 

 

 

 

 

 

Fixed to OFF*

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit 3

 

Protocol

 

 

 

 

 

 

 

PS Data*

 

Camera Communication

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit 4

 

Reserved

 

 

 

 

 

 

 

Fixed to OFF*

 

Not used

 

 

 

 

 

 

 

 

 

 

Bit 5

 

Line termination

 

 

 

 

Off

 

On*

 

 

 

 

 

 

 

 

 

 

 

Bit 6

 

RS-485 mode

 

 

 

 

 

4-line full duplex*

 

2-line half duplex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Number Setting

A rotary switch is placed on the front panel. It specifies the WJ-MP204C unit number in a PS Data protocol system, or camera unit numbers in a Camera Communication Protocol system.

8Setting the unit number

1Turn off the power switch of the unit.

2Use a screw driver to rotate the UNIT switch so that the arrow comes to the number you wish.

3Turn on the power switch.

UNIT

9

8 7

6

0

1

 

2

 

3

5

4

 

Notes:

The unit number can be specified in the setup menu when the UNIT switch is set to "0."

Position #9 is not allowed to be set, because it is reserved.

Specify a unique number for each unit when connecting more than one unit in a data communication chain.

15

Image 15
Contents Operating Instructions English Version Important Safety Instructions Contents Preface FeaturesHandle the appliance with care PrecautionsDo not drop metallic parts through slots Do not attempt to disassemble the applianceFront View Rear View Mounting two WJ-MP204Cs with the WV-Q204/2 InstallationMounting in the Rack Mounting One WJ-MP204C with the WV-Q204/1Control Site Connection & SettingBasic Connection PS Data Camera SiteCamera Site UnitMultiConnection PS DataMode Video Multiplexer Connection PS DataWV-CU50 Digital Disk Recorder Connection PS DataWJ-MP204C Matrix Switcher Connection Camera CommunicationOFF DIP Switch SettingUnit Number Setting Setting the unit numberCamera IN/OUT Alarm/Remote Terminal SettingPS Data Camera Communication ProtocolRS-485 Data Port Connection PS Data Internal SettingDaisy Connection Internal Diagram Line Half DuplexRS-485 Terminal Connection Camera Communication Basic ConnectionWJ-MP204C Setup MENUX.XX Communication System Setup ProceduresPrior to setup Buttons used in the setupSetup menus Communication Unit Address Baud Rate Setup Menus for PS DataCommunication setup PS Data System setup PS DataAlarm mode setup Alarm DataAlarm CAM no PRE 1CH 2CH 3CH 4CH Available channels 1CH, 2CH, 3CH, 4CH Cable compensation/VD2 sync/data setupVS/VD input setup COMP/VD2/DATA Camera in 1CH Comp S VD2 on Data onCommunication setup Camera Communication Camera Config CAM no 1CH 2CH 3CH 4CHCommunication CAM Address Baud Rate CAM Address Camera 1CH 2CH 3CH 4CH System setup Camera Communication ProtocolAvailable delay times ms OFF, 10, 20, 40 Not USE DisabledAlarm Data AUTO2 Alarm Alarm Operation OperationCamera Selection External resetting Alarm ResetAlarm Suspension Manual resettingSpecifications ALL Reset Standard AccessoriesPanasonic Canada Inc