Panasonic WJ-MP204C manual Alarm mode setup, Alarm Data, Alarm CAM no PRE 1CH 2CH 3CH 4CH

Page 22

8Alarm mode setup

1.Move the cursor to ALARM MODE to select ON or OFF with the [–] or [+] button, then press SET. The default setting is ON.

ON : Opens a submenu shown below.

OFF: Alarm mode is disabled.

The ALARM MODE sub menu appears.

ALARM MODE

 

 

 

 

 

MONITOR SPOT

 

 

 

 

 

ON

ALARM DISPLAY

 

 

 

 

 

ON

SITE ALARM

 

 

 

 

 

ON

TERM.ALARM

 

 

 

 

ON

ALARM OUTPUT

 

 

 

10S

ALARM DATA

 

 

1S

1-1. Move the cursor to MONITOR SPOT to select ON or OFF with the [–] or [+] button, then press SET. The default setting is ON .

This setting specifies whether to change the monitor image when an alarm operates.

ON : Image display on the monitor changes to that of the alarm activated channel.

OFF: Image display will not change even when an alarm operates.

The MONITOR SPOT sub menu appears.

 

MONITOR SPOT

ALARM

CAM NO.

PRE

1

 

 

 

 

 

 

 

1CH

-

2

 

 

 

 

 

 

 

2CH

-

3

 

 

 

 

 

 

 

3CH

-

4

 

 

 

 

 

 

 

4CH

-

1-2. In this setup, the relation is established between four alarm channels and four camera channels, along with the preset positions to which the camera moves when the alarm operates.

1-2-1. Move the cursor to a channel of CAM. NO with the [D] or [C] button.

1-2-2. Select a CAM. NO with the [–] or [+] button, then press the [C]. The cursor moves to PRE. The default setting is that the same numbers are assigned to both alarm channel and camera chan- nel.

1CH: Camera input 1 will be displayed when the respective alarm operates.

2CH: Camera input 2 will be displayed.

3CH: Camera input 3 will be displayed.

4CH: Camera input 4 will be displayed.

1-2-3. Select a PRE (preset position number) with the [–] or [+] button, then press the [C].

1-2-4. Repeat above steps for other alarm channels.

1-2-5. Press the ESC to return to the ALARM MODE menu.

2.Move the cursor to ALARM DISPLAY. Select ON or OFF with the [–] or [+] button. The default setting is ON. Alarm display “ALARM ***” on the monitor is enabled or disabled while an alarm is in operation. “***” is the alarm channel number.

ON: Enabled.

OFF: Disabled.

3.Move the cursor to SITE ALARM. Select ON or OFF with the [–] or [+] button. The default setting is ON.

A site alarm (motion detection) generated by a camera is accepted or ignored.

ON: Enabled.

OFF: Disabled.

4.Move the cursor to TERM. ALARM (terminal alarm). Select ON or OFF with the [–] or [+] button. The default setting is ON.

An alarm input to the rear terminal is accepted or ignored.

ON: Enabled.

OFF: Disabled.

5.Move the cursor to ALARM OUTPUT. Select an output duration with the [–] or [+] button. The default setting is 10S (seconds).

The output status is supplied to the terminals on the rear. The output is reset along with the activated alarm according to this setup.

EXT: The output is reset when a reset input is supplied to the rear panel or the alarm reset button is pressed on the front panel.

1S-5MIN:The output is reset when the preset duration elapses.

OFF: No output.

6.Move the cursor to ALARM DATA. Select an output time with the [–] or [+] button. The default setting is 1S (sec- ond).

The unit notifies the connected System Controller (must be set to Unit #1) of the alarm activation once every period preset by this setup.

OFF: No notification.

0S: Notification is made immediately.

1S: Notification is made once every 1 second.

5S: Notification is made once every 5 second.

7.Press the ESC to go back to the SYSTEM menu.

22

Image 22
Contents Operating Instructions English Version Important Safety Instructions Contents Features PrefaceDo not attempt to disassemble the appliance PrecautionsDo not drop metallic parts through slots Handle the appliance with careFront View Rear View Mounting One WJ-MP204C with the WV-Q204/1 InstallationMounting in the Rack Mounting two WJ-MP204Cs with the WV-Q204/2Camera Site Connection & SettingBasic Connection PS Data Control SiteUnitMultiConnection PS Data Camera SiteVideo Multiplexer Connection PS Data ModeDigital Disk Recorder Connection PS Data WV-CU50Matrix Switcher Connection Camera Communication WJ-MP204CSetting the unit number DIP Switch SettingUnit Number Setting OFFCamera Communication Protocol Alarm/Remote Terminal SettingPS Data Camera IN/OUTInternal Setting RS-485 Data Port Connection PS DataBasic Connection Internal Diagram Line Half DuplexRS-485 Terminal Connection Camera Communication Daisy ConnectionButtons used in the setup Setup ProceduresPrior to setup WJ-MP204C Setup MENUX.XX Communication SystemSetup menus System setup PS Data Setup Menus for PS DataCommunication setup PS Data Communication Unit Address Baud RateAlarm Data Alarm mode setupAlarm CAM no PRE 1CH 2CH 3CH 4CH COMP/VD2/DATA Camera in 1CH Comp S VD2 on Data on Cable compensation/VD2 sync/data setupVS/VD input setup Available channels 1CH, 2CH, 3CH, 4CHCamera Config CAM no 1CH 2CH 3CH 4CH Communication setup Camera CommunicationCommunication CAM Address Baud Rate Not USE Disabled System setup Camera Communication ProtocolAvailable delay times ms OFF, 10, 20, 40 CAM Address Camera 1CH 2CH 3CH 4CHAlarm Data AUTO2 Alarm Operation Alarm OperationCamera Selection Manual resetting Alarm ResetAlarm Suspension External resettingSpecifications Standard Accessories ALL ResetPanasonic Canada Inc