CONNECTION & SETTING

Shown below are some system connection examples using Data Multiplex unit with peripheral devices in PS Data (Panasonic Security Data) or the Camera Communication Protocols. Note that all system devices in a system should use the same proto- col.

Basic Connection (PS Data)

Up to four cameras are connected with the unit at a camera site while a System Controller operates camera selection, pan/tilt and lens control at a control site.

Camera

4 ch

1 ch

2 ch

3 ch

Camera Site

IN

4

3

2

1

IN

IN

ALARM / REMOTE

 

Monitor

 

 

 

 

 

 

T

R

 

 

 

 

 

 

 

G B A B

A

SIGNAL GND

 

 

 

 

 

 

 

 

 

OUT

4

3

2

1

OUT

OUT

 

 

 

 

 

CAMERA

 

 

SPOT

VS/VD

RS485

DATA

MODE

Termination ON

Controller No. 1

OPERATE

LOGIN

ALARM

MONITOR

CAMERA

BUSY PROHIBITED

UNIT

 

 

 

 

 

System Controller WV-CU 360

 

PROGRAM

 

SETUP

CAM SETUP

IRIS

 

CLOSE

OPEN

SHIFT

FUNCTION

CAM FUNCTION

 

IRIS RESET

UP

ALM RESET

ALM SUSPEND

AUTO

UNIT A

FOCUS

 

NEAR

FAR

ALM RECALL

 

B/W

UNIT

AUTO FOCUS

 

VTR CAM

MULTI SCREEN SELECT

DEF

 

L

R

 

 

 

UNIT B

ZOOM

 

 

 

AUX 2

TELE

STILL

EL-ZOOM

WIDE

WIPER

 

DOWN

 

+

 

AUX 1

 

 

 

 

 

 

 

 

SEQ PAUSE

SEQUENCE

PATROL PLAY

MON

 

 

 

CAM

HOME/PRESET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODE

System Controller WV-CU360C

4-Line Termination ON

Panasonic Security Data mode

SLOW

PATROL

PATROL

ESC LOGOUT SET

PROGRAM

 

STOP

LEARN

 

PRESET

Control Site

Video signal

RS485 signal

(Panasonic Security Data mode)

10

Image 10
Contents Operating Instructions English Version Important Safety Instructions Contents Features PrefaceDo not attempt to disassemble the appliance PrecautionsDo not drop metallic parts through slots Handle the appliance with careFront View Rear View Mounting One WJ-MP204C with the WV-Q204/1 InstallationMounting in the Rack Mounting two WJ-MP204Cs with the WV-Q204/2Camera Site Connection & SettingBasic Connection PS Data Control SiteUnitMultiConnection PS Data Camera SiteVideo Multiplexer Connection PS Data ModeDigital Disk Recorder Connection PS Data WV-CU50Matrix Switcher Connection Camera Communication WJ-MP204CSetting the unit number DIP Switch SettingUnit Number Setting OFFCamera Communication Protocol Alarm/Remote Terminal SettingPS Data Camera IN/OUTInternal Setting RS-485 Data Port Connection PS DataBasic Connection Internal Diagram Line Half DuplexRS-485 Terminal Connection Camera Communication Daisy ConnectionButtons used in the setup Setup ProceduresPrior to setup WJ-MP204C Setup MENUX.XX Communication SystemSetup menus System setup PS Data Setup Menus for PS DataCommunication setup PS Data Communication Unit Address Baud RateAlarm Data Alarm mode setupAlarm CAM no PRE 1CH 2CH 3CH 4CH COMP/VD2/DATA Camera in 1CH Comp S VD2 on Data on Cable compensation/VD2 sync/data setupVS/VD input setup Available channels 1CH, 2CH, 3CH, 4CHCamera Config CAM no 1CH 2CH 3CH 4CH Communication setup Camera CommunicationCommunication CAM Address Baud Rate Not USE Disabled System setup Camera Communication ProtocolAvailable delay times ms OFF, 10, 20, 40 CAM Address Camera 1CH 2CH 3CH 4CHAlarm Data AUTO2 Alarm Operation Alarm OperationCamera Selection Manual resetting Alarm ResetAlarm Suspension External resettingSpecifications Standard Accessories ALL ResetPanasonic Canada Inc