Alarm Reset

Alarms are reset according to the reset mode (EXT, auto (1S-5M) or OFF) selected in the ALARM OUTPUT setup.

Manual resetting

Pressing the RESET button on the unit resets the activated alarm.

Pressing the ALARM RESET button on the controller resets the activated alarm.

External resetting

Input to the ALARM/REMOTE terminal resets the activated alarm when the terminal is set to the alarm input mode.

Auto resetting

Elapsing of the preset time resets the activated alarm, except for the unit's alarm indicator which remains on steady light.

Alarm Suspension

This function is used in the setup operation or whenever you do not wish to accept alarm inputs.

Press the ALARM SUSPEND button on the front panel, or ALM SUSPEND on the controller. Alarm inputs will be ignored while the indicator is lit.

Press the button again to release the alarm suspension. Alarm inputs will be accepted after the indicator turns off.

Function

WJ-MP204C

WV-CU360C

 

 

 

 

 

 

 

Enter a camera number with

 

 

 

 

numeric buttons.

Camera Selection

 

 

 

CAM

CAM

2

3

4

 

1

#

then

 

 

 

 

 

 

 

 

 

SET

ALM RESET

Alarm Reset

ALARM

RESET

ALM RECALL

ALARM

 

ALM SUSPEND

 

Alarm Suspend

SUSPEND

 

SET

Alarm Suspend

ALARM

ALM SUSPEND

 

SUSPEND

Reset

 

 

SET

 

 

29

Image 29
Contents Operating Instructions English Version Important Safety Instructions Contents Preface FeaturesDo not drop metallic parts through slots PrecautionsDo not attempt to disassemble the appliance Handle the appliance with careFront View Rear View Mounting in the Rack InstallationMounting One WJ-MP204C with the WV-Q204/1 Mounting two WJ-MP204Cs with the WV-Q204/2Basic Connection PS Data Connection & SettingCamera Site Control SiteCamera Site UnitMultiConnection PS DataMode Video Multiplexer Connection PS DataWV-CU50 Digital Disk Recorder Connection PS DataWJ-MP204C Matrix Switcher Connection Camera CommunicationUnit Number Setting DIP Switch SettingSetting the unit number OFFPS Data Alarm/Remote Terminal SettingCamera Communication Protocol Camera IN/OUTRS-485 Data Port Connection PS Data Internal SettingRS-485 Terminal Connection Camera Communication Internal Diagram Line Half DuplexBasic Connection Daisy ConnectionPrior to setup Setup ProceduresButtons used in the setup WJ-MP204C Setup MENUX.XX Communication SystemSetup menus Communication setup PS Data Setup Menus for PS DataSystem setup PS Data Communication Unit Address Baud RateAlarm CAM no PRE 1CH 2CH 3CH 4CH Alarm mode setupAlarm Data VS/VD input setup Cable compensation/VD2 sync/data setupCOMP/VD2/DATA Camera in 1CH Comp S VD2 on Data on Available channels 1CH, 2CH, 3CH, 4CHCommunication CAM Address Baud Rate Communication setup Camera CommunicationCamera Config CAM no 1CH 2CH 3CH 4CH Available delay times ms OFF, 10, 20, 40 System setup Camera Communication ProtocolNot USE Disabled CAM Address Camera 1CH 2CH 3CH 4CHAlarm Data AUTO2 Alarm Camera Selection Alarm OperationOperation Alarm Suspension Alarm ResetManual resetting External resettingSpecifications ALL Reset Standard AccessoriesPanasonic Canada Inc