Panasonic WJ-MP204C manual Cable compensation/VD2 sync/data setup, VS/VD input setup

Page 23

8Cable compensation/VD2 sync/data setup

The COMP/VD2/DATA menu is displayed when you select it in the SYSTEM menu.

COMP/VD2/DATA

CAMERA IN 1CH

COMP S

VD2 ON

DATA ON

In this menu, each camera is set up for cable compensa- tion, VD2 sync and data communication ON/OFF.

1.Move the cursor to CAMERA IN. Select a camera input channel with the [–] or [+] button. The default setting is 1CH.

The camera channel to be set up is selected and the image of the channel is displayed in the background of the setup menu.

Available channels: 1CH, 2CH, 3CH, 4CH

2.Move the cursor to COMP. Select a parameter with the [–] or [+] button. The default setting is S.

The longer a coaxial cable is extended, the more the video signals attenuate. This setting is to compensate signal attenuation in 3 degrees. Select the best para- meter that optimizes the displayed image on the moni- tor while observing it.

S:Short distance of less than 1 300 ft (400 m)

M:Medium distance between 1 300 ft (400 m) and 2 300 ft (700 m)

L:Long distance of less than 3 000 ft (900 m)

Note: Distance is based on the assumption that RG- 59U, BELDEN 9259 or equivalent cable is used.

3.Move the cursor to VD2. Select a parameter with the [–] or [+] button. The default setting is ON.

The VD2 sync signal is multiplexed onto the coaxial cable and sent to the camera for synchronization. Refer to the table.

ON: VD2 synchronizes with the input to the VS/VD con- nector when supplied, or with the internal sync when VS/VD has no input.

THRU: VD2 is supplied when a camera out connector accepts external VD2 from the connected device. No VD2 is supplied when no camera out connector accepts external VD2.

OFF: No VD2 is supplied to the camera.

4.Move the cursor to DATA. Select ON or OFF with the [–] or [+] button. The default setting is ON.

Data communication with the selected camera channel is enabled or disabled.

ON: Enabled.

OFF: Disabled.

5.Press the ESC to return to the SYSTEM menu.

8VS/VD input setup

This setting specifies the input to the VS/VD INPUT terminal on the rear of the unit.

1.Move the cursor to VS/VD INPUT. Select VS or VD with the [–] or [+] button. The default setting is VD.

VD: Set this when a “vertical drive” is input (4 V[p-p]).

VS: Set this when “video and sync” are input (1 V[p-p]).

VS/VD

Input setup

VS/VD OUT signal

IN signal

required

MODE #1 to VD

MODE #1 to THRU

C.Sync

VS

VD: sync to

C.Sync: looped

input

through

 

 

VBS

VS

VD: sync to

VBS: looped

input

through

 

 

VD

VD

VD: sync to

VD: looped

input

through

 

 

No input

VD

VD: internal

No output

Beside VS/VD OUT signal, the unit supplies VD2 sync to the cameras as follows.

VS/VD Input

External VD2 to

 

VD2 supplied to cameras

 

CAM OUT

VD2 set to ON

VD2 set to THRU

VD2 set to OFF

 

Yes

Yes

Sync to VS/VD

Sync to Ext VD2

Not supplied

Yes

No

Sync to VS/VD

Not supplied

Not supplied

No

Yes

Sync to internal

Sync to Ext VD2

Not supplied

No

No

Sync to internal

Not supplied

Not supplied

23

Image 23
Contents Operating Instructions English Version Important Safety Instructions Contents Preface FeaturesHandle the appliance with care PrecautionsDo not drop metallic parts through slots Do not attempt to disassemble the applianceFront View Rear View Mounting two WJ-MP204Cs with the WV-Q204/2 InstallationMounting in the Rack Mounting One WJ-MP204C with the WV-Q204/1Control Site Connection & SettingBasic Connection PS Data Camera SiteCamera Site UnitMultiConnection PS DataMode Video Multiplexer Connection PS DataWV-CU50 Digital Disk Recorder Connection PS DataWJ-MP204C Matrix Switcher Connection Camera CommunicationOFF DIP Switch SettingUnit Number Setting Setting the unit numberCamera IN/OUT Alarm/Remote Terminal SettingPS Data Camera Communication ProtocolRS-485 Data Port Connection PS Data Internal SettingDaisy Connection Internal Diagram Line Half DuplexRS-485 Terminal Connection Camera Communication Basic ConnectionWJ-MP204C Setup MENUX.XX Communication System Setup ProceduresPrior to setup Buttons used in the setupSetup menus Communication Unit Address Baud Rate Setup Menus for PS DataCommunication setup PS Data System setup PS DataAlarm CAM no PRE 1CH 2CH 3CH 4CH Alarm mode setupAlarm Data Available channels 1CH, 2CH, 3CH, 4CH Cable compensation/VD2 sync/data setupVS/VD input setup COMP/VD2/DATA Camera in 1CH Comp S VD2 on Data onCommunication CAM Address Baud Rate Communication setup Camera CommunicationCamera Config CAM no 1CH 2CH 3CH 4CH CAM Address Camera 1CH 2CH 3CH 4CH System setup Camera Communication ProtocolAvailable delay times ms OFF, 10, 20, 40 Not USE DisabledAlarm Data AUTO2 Alarm Camera Selection Alarm OperationOperation External resetting Alarm ResetAlarm Suspension Manual resettingSpecifications ALL Reset Standard AccessoriesPanasonic Canada Inc