Panasonic PT-DW5100EL manual Status function, Automatic adjustment, Press the Shutter button again

Page 25

How to adjust the lens position to the left or right

When the lens left/right adjustment dial is turned clockwise, the screen moves toward the left; conversely, when it is turned counterclockwise, it moves toward the right. The maximum travel distance toward the left or right is about 10 % of the projection screen width.

The screen

The screen

moves toward

moves toward

the right

the left

Lens left/right

adjustment dial

Maximum

adjustment

position

Attention • Move the lens left/right adjustment dial to any position up to the maximum

adjustment position to make the adjustment. Turning the dial with undue force may cause malfunctioning.

Status function

This shows the projector status. It can also be used to send information about the projector’s status via E- mail.

Press the STATUS button on the remote control.

STATUS

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

NTSC

 

VIDEO

 

 

 

 

15.73kHz/59.94Hz

 

 

PROJECTOR RUNTIME

 

33h

 

 

LAMP1

13h/

ON/

 

 

LAMP2

13h/

ON/

 

 

INTAKE-AIR TEMP.

25 °C /

77 °F

 

 

OPTICS MODULE TEMP.

37 °C /

98 °F

 

 

TEMP. AROUND LAMP

37 °C /

98 °F

 

MAIN VERSION

1.00.00

NETWORK VERSION

1.00

REMOTE2

DISABLE

SEND STATUS VIA E-MAIL

EXIT

Note • For details, refer to “Setting the network”, “Connecting the PC” and “Using Web Browser Control” (pages 39 to 48).

Automatic adjustment

(AUTO SETUP)

Automatic adjustment function adjust the resolution, clock phase and image position automatically when dots-structured analogue RGB signals such as computer signal are supplied. (Automatic adjustment is not available if moving picture input signals or signals having a dot clock frequency of more than 150 MHz are supplied.) When DVI signals are input, the image position is adjusted automatically.

It is recommended to supply images with a bright white frame at the outermost periphery containing characters etc. that are clear in white and black contrast when the system is in automatic adjustment mode. Avoid supplying images that involve halftones or gradation such as photographs and computer graphics.

Note • “CLOCK PHASE” may have been shifted

ENGLISH

even when the adjustment ended

 

normally. In this case, manually adjust the

 

“CLOCK PHASE”.

 

• Automatic adjustments cannot be

 

performed when images with blurred

 

edges or dark images are input.

 

With Composite sync and G-SYNC sync

 

signals and some types of PCs, it may not

 

be possible to perform these automatic

 

adjustments.

 

In this case, manually adjust the items of

 

“INPUT RESOLUTION”, “CLOCK PHASE”

 

and “SHIFT”.

 

• Image may be disturbed for about 4

 

seconds during automatic adjustment,

 

which is not an abnormal error.

 

Using the SHUTTER function

If the projector is not going to be used for a certain period of time such as while a meeting is on a break or preparations are being made, the mechanical shutter can be used to hide the images temporarily.

Press the SHUTTER button of the remote control or the main unit.

The image is turned off.

Press the SHUTTER button again.

The image comes back.

25

Image 25
Contents Operating Instructions Model number PT-D5700E/PT-D5700EL/PT-DW5100E/PT-DW5100EL Dear Panasonic CustomerImportant the Moulded Plug U.K. only For Your SAFETY, Please Read the Following Text CarefullyContents Precautions with regard to safety Do not use or handle the batteries improperly Remove empty batteries from the remote control at onceDo not disassemble the lamp unit Always disconnect all cables before moving the projectorDo not use the old lamp unit AccessoriesDo not place the projector in extremely hot locations Precautions on handling Name and function of parts Remote controlBottom Status LED lights Front and side of the projectorRear view of the main unit Controls on rear panel Side-mounted connection terminals Effective range of remote control operation Using the remote control unitLoading dry cells Connect to the projector to use with a cable Setting projector ID number to remote controlInstallation geometry InstallationProjection schemes Unit mmPT-D5700E, PT-D5700EL Projection distance by projection lensScreen aspect ratio PT-DW5100E, PT-DW5100EL InstallationCalculation formulas for projection distance by lens types Connection Setup precautionsExample of connecting with PCs Example of connecting with AV productsMaking adjustment and selection Powering up the projectorPress the I button. on the main unit or the remote control ProjectionDirect power off function Powering off the projectorHow to adjust the FOCUS, Zoom and Shift How to adjust the lensHow to remove the projection lens Press the Status button on the remote control Automatic adjustmentStatus function Press the Shutter button againStructure of menu screens On-screen menusResetting to the factory default Menu items settingBasic menu operations Returning to the previousAdjusting the picture Adjusting the position Zoom Clock PhaseKeystone Digital Cinema RealityClamp Position Input ResolutionEdge Blending Sxga Mode XGA ModePress to select an item, and press to adjust the setting Raster PositionPress the Enter button Press to adjust the values OPTION1 settingsColor Matching Press to select R, G, B and WhAuto Signal Contrast ModeColor Correction Back ColorDVI Edid DVI Signal LevelFUNC1 OSD PositionInstallation OPTION2 settingsProjector ID AltitudeLamp Select Lamp PowerLamp Relay RS-232CPassword Auto Power OFFSystem Information Cycle of displayed internal test patternsConnecting the PC Setting the networkSystem requirements Connection exampleAccessing from the Web browser Using Web Browser ControlPassword change Click OKBasic control Monitor information Detail controlOptics Module Error informationMail set up Authentication server set up Ping test DNS server set upAdjust clock Contents of mail sentNetwork status Network configSupported commands Using the PJLink protocolPJLink security authentication Command Control Description RemarksPassword Change Setting the securityDisplay Setting Control Device SetupPin assignments and signal names Using the serial terminalsCommunication conditions Factory setting Examples of connectionCable specifications Control commandsConnecting to a PC Computer Projector DTE specifications Pin assignments and controlIndication of lamp monitor Procedure of cleaning Cleaning and replacement of air filterClean the air filter Dismantle the air filterReplacing the lamp unit When to replace the Lamp unitLamp AfterRemove the two screws securing the fan unit Lamp unit replacement stepsLamp unit will be hot after it has been used Have a Phillips screwdriver ready ahead of timeInstallation procedure Ceiling Mount Bracket SafeguardsNot turn on Power doesNo image Image is blurredPT-D5700E PT-D5700EL PT-DW5100E SpecificationsOutside dimensions Length of power cord CabinetRemote control Power source Replacement lamp unitPAL-M/PAL60 PAL/PAL-N/SECAM Compatible Signal ListInstallation dimensions diagram DimensionsFor business users in the European Union Trademark Acknowledgement