Panasonic PT-DW5100EL, PT-D5700EL manual Authentication server set up

Page 45

Enter the E-mail address to which the E-mail is to be sent when two E-mail addresses are going to be used. Do not enter it when the second E-mail address is not going to be used.

Check these boxes when E-mail is to be sent periodically to two E-mail addresses. E-mail will be sent at the times and on the days checked.

Button to update settings

Select the conditions for sending the second E-mail. ERROR: an error is detected by self-diagnosis.

LAMP RUNTIME: remaining lamp service time has reached the value set in the field.

INPUT AIR TEMPERATURE: intake air temperature has reached the value set in the field.

Note • Only alphanumeric characters, “.”, “_”, “-”, or “@” are available to set an E-mail address.

ENGLISH

Authentication server set up page

The authentication server is set on this page when POP authentication or SMTP authentication is required for mail transmissions. Click [Network set up], then [Authentication set up] to display the authentication server set up page.

Change the authentication method as desired.

For SMTP authentication, change the authentication method to use, as desired.

Enter the POP server name. Available input characters: alphanumeric characters (A - Z, a - z, 0 - 9), hyphen (-) period (.)

Enter the user name for the SMTP or

POP server.

Enter the password for the SMTP or

POP server.

Enter the SMTP server port number.

Enter the POP server port number.

Button to update settings

45

Image 45
Contents Operating Instructions Model number PT-D5700E/PT-D5700EL/PT-DW5100E/PT-DW5100EL Dear Panasonic CustomerImportant the Moulded Plug U.K. only For Your SAFETY, Please Read the Following Text CarefullyContents Precautions with regard to safety Do not use or handle the batteries improperly Remove empty batteries from the remote control at onceDo not disassemble the lamp unit Always disconnect all cables before moving the projectorAccessories Do not use the old lamp unitDo not place the projector in extremely hot locations Precautions on handling Name and function of parts Remote controlBottom Status LED lights Front and side of the projectorRear view of the main unit Controls on rear panel Side-mounted connection terminals Using the remote control unit Effective range of remote control operationLoading dry cells Connect to the projector to use with a cable Setting projector ID number to remote controlInstallation geometry InstallationProjection schemes Unit mmProjection distance by projection lens PT-D5700E, PT-D5700ELScreen aspect ratio PT-DW5100E, PT-DW5100EL InstallationCalculation formulas for projection distance by lens types Connection Setup precautionsExample of connecting with PCs Example of connecting with AV productsMaking adjustment and selection Powering up the projectorPress the I button. on the main unit or the remote control ProjectionDirect power off function Powering off the projectorHow to adjust the lens How to adjust the FOCUS, Zoom and ShiftHow to remove the projection lens Press the Status button on the remote control Automatic adjustmentStatus function Press the Shutter button againStructure of menu screens On-screen menusResetting to the factory default Menu items settingBasic menu operations Returning to the previousAdjusting the picture Adjusting the position Zoom Clock PhaseKeystone Digital Cinema RealityInput Resolution Clamp PositionEdge Blending Sxga Mode XGA ModePress to select an item, and press to adjust the setting Raster PositionPress the Enter button Press to adjust the values OPTION1 settingsColor Matching Press to select R, G, B and WhAuto Signal Contrast ModeColor Correction Back ColorDVI Edid DVI Signal LevelFUNC1 OSD PositionInstallation OPTION2 settingsProjector ID AltitudeLamp Select Lamp PowerLamp Relay RS-232CPassword Auto Power OFFSystem Information Cycle of displayed internal test patternsConnecting the PC Setting the networkSystem requirements Connection exampleAccessing from the Web browser Using Web Browser ControlPassword change Click OKBasic control Monitor information Detail controlOptics Module Error informationMail set up Authentication server set up Ping test DNS server set upAdjust clock Contents of mail sentNetwork status Network configSupported commands Using the PJLink protocolPJLink security authentication Command Control Description RemarksPassword Change Setting the securityDisplay Setting Control Device SetupPin assignments and signal names Using the serial terminalsCommunication conditions Factory setting Examples of connectionCable specifications Control commandsConnecting to a PC Computer Projector DTE specifications Pin assignments and controlIndication of lamp monitor Procedure of cleaning Cleaning and replacement of air filterClean the air filter Dismantle the air filterReplacing the lamp unit When to replace the Lamp unitLamp AfterRemove the two screws securing the fan unit Lamp unit replacement stepsLamp unit will be hot after it has been used Have a Phillips screwdriver ready ahead of timeInstallation procedure Ceiling Mount Bracket SafeguardsNot turn on Power doesNo image Image is blurredPT-D5700E PT-D5700EL PT-DW5100E SpecificationsOutside dimensions Length of power cord CabinetRemote control Power source Replacement lamp unitPAL-M/PAL60 PAL/PAL-N/SECAM Compatible Signal ListInstallation dimensions diagram DimensionsFor business users in the European Union Trademark Acknowledgement