Panasonic PT-DW5100EL, PT-D5700EL manual Mail set up

Page 44

Using Web Browser Control

E-mail set up page

With this projector, if a problem occurs or if the lamp usage time reaches a set value, an E-mail message can be sent to one or more preset E-mail addresses (maximum two addresses). Click [Projector control], then [E-mail set up] to display the E-mail set up page.

The user can modify the threshold temperature for sending temperature warning mail. If the temperature rises above the set value, control sends temperature warning mail.

Select “Enable” to use the E-mail function.

Enter the IP address or server name of the E-mail server (SMTP). The DNS server must be set if the server name is entered.

Enter the E-mail address of the projector. (maximum 63 characters)

The user can enter the location of, for example, the installed projector so that the recipient may easily identify the originator of the E-mail.

(maximum 63 characters)

The user can modify the minimum time interval of temperature warning mail. The default value is 60 minutes. In this case, the user cannot send another mail for 60 minutes after sending previous temperature warning mail even the set warning temperature is reached again.

Enter the E-mail address of your desired recipient.

Select the conditions for sending E-mail.

ERROR:

an error is detected by self- diagnosis.

LAMP RUNTIME:

remaining lamp service time has reached the value set in the field.

INPUT AIR TEMPERATURE:

intake air temperature has reached the value set in the field.

Periodic warning interval setting (E-mail is sent on the checked days of the week/times)

44

Image 44
Contents Operating Instructions Dear Panasonic Customer Model number PT-D5700E/PT-D5700EL/PT-DW5100E/PT-DW5100ELFor Your SAFETY, Please Read the Following Text Carefully Important the Moulded Plug U.K. onlyContents Precautions with regard to safety Remove empty batteries from the remote control at once Do not use or handle the batteries improperlyDo not disassemble the lamp unit Always disconnect all cables before moving the projectorDo not place the projector in extremely hot locations AccessoriesDo not use the old lamp unit Precautions on handling Remote control Name and function of partsBottom Front and side of the projector Status LED lightsRear view of the main unit Controls on rear panel Side-mounted connection terminals Loading dry cells Using the remote control unitEffective range of remote control operation Setting projector ID number to remote control Connect to the projector to use with a cableInstallation Installation geometryProjection schemes Unit mmScreen aspect ratio Projection distance by projection lensPT-D5700E, PT-D5700EL Installation PT-DW5100E, PT-DW5100ELCalculation formulas for projection distance by lens types Setup precautions ConnectionExample of connecting with AV products Example of connecting with PCsPowering up the projector Making adjustment and selectionPress the I button. on the main unit or the remote control ProjectionPowering off the projector Direct power off functionHow to remove the projection lens How to adjust the lensHow to adjust the FOCUS, Zoom and Shift Automatic adjustment Press the Status button on the remote controlStatus function Press the Shutter button againOn-screen menus Structure of menu screensMenu items setting Resetting to the factory defaultBasic menu operations Returning to the previousAdjusting the picture Adjusting the position Clock Phase ZoomKeystone Digital Cinema RealityEdge Blending Input ResolutionClamp Position XGA Mode Sxga ModePress to select an item, and press to adjust the setting Raster PositionOPTION1 settings Press the Enter button Press to adjust the valuesColor Matching Press to select R, G, B and WhContrast Mode Auto SignalColor Correction Back ColorDVI Signal Level DVI EdidFUNC1 OSD PositionOPTION2 settings InstallationProjector ID AltitudeLamp Power Lamp SelectLamp Relay RS-232CAuto Power OFF PasswordSystem Information Cycle of displayed internal test patternsSetting the network Connecting the PCSystem requirements Connection exampleUsing Web Browser Control Accessing from the Web browserPassword change Click OKBasic control Detail control Monitor informationError information Optics ModuleMail set up Authentication server set up DNS server set up Ping testContents of mail sent Adjust clockNetwork config Network statusUsing the PJLink protocol Supported commandsPJLink security authentication Command Control Description RemarksSetting the security Password ChangeDisplay Setting Control Device SetupUsing the serial terminals Pin assignments and signal namesCommunication conditions Factory setting Examples of connectionControl commands Cable specificationsConnecting to a PC Computer Projector DTE specifications Pin assignments and controlIndication of lamp monitor Cleaning and replacement of air filter Procedure of cleaningClean the air filter Dismantle the air filterWhen to replace the Lamp unit Replacing the lamp unitLamp AfterLamp unit replacement steps Remove the two screws securing the fan unitLamp unit will be hot after it has been used Have a Phillips screwdriver ready ahead of timeCeiling Mount Bracket Safeguards Installation procedurePower does Not turn onNo image Image is blurredSpecifications PT-D5700E PT-D5700EL PT-DW5100ELength of power cord Cabinet Outside dimensionsRemote control Power source Replacement lamp unitCompatible Signal List PAL-M/PAL60 PAL/PAL-N/SECAMDimensions Installation dimensions diagramFor business users in the European Union Trademark Acknowledgement