Agilent Technologies 66001A manual USER’S Guide, Agilent Part No Microfiche Part No September

Page 1

USER’S GUIDE

Agilent Technologies

Series 661xxA

MPS POWER MODULES

& Model 66001A MPS KEYBOARD

!A

Agilent Part No. 5959-3386

Printed in Malaysia

Microfiche Part No. 5959-3387

September 2004

Image 1
Contents Agilent Part No Microfiche Part No September USER’S GuideCertification Safety Summary Printing History Symbol DescriptionHerstellerbescheinigung Manufacturers DeclarationUSA Manufacturer’s Name and AddressModel Numbers a 66000A Page Table of Contents Using the Agilent 66001A MPS Keyboard Basic Power Module CommandsOption Description Item DescriptionGeneral Information Accessories Programming Accuracy @ calibration temperature ± 5 C Specifications and Supplemental CharacteristicsOutput Ratings Readback AccuracySupplemental Characteristics Parameter Performance Specifications ParameterAgilent Model 66101A 66102A 66103A 66104A 66105A 66106A Remote Sensing Capability 66101A 66102A Agilent Model 66103A 66104A 66105A 66106ADimensions Recommended Calibration Interval Safety ComplianceWeight Downprogramming Monotonicity Gpib Interface CapabilitiesOutput Characteristic Curve Supplemental CharacteristicsReplaceable Parts List Description Agilent Part No Parameter Agilent Model Number and Parameter ValuePage Switches InstallationInspection Power Module Line Fuse and Switches Switch Setting RI Action Remote Inhibit RI Function SwitchesDisplay Function Switch Calibration Function SwitchesConnecting The Load Installing The Module In The MainframeOutput Connector Output Connections Selecting the Proper Wire SizeResistance Ω/ft AWG No. *AmpacityVoltage Readback Remote Voltage SensingOutput Noise Output RatingParallel Operation Voltlev Outp OFFVoltprot Currlev Voltlev Voltprot Currlev MAX Outp onCapacitive Loads Multiple LoadsBattery Charging Connecting The ControllerInductive Loads OVP ConsiderationsTurn-On Checkout Power Module Front Panel DisplayIntroduction Module Panel DisplayChecking Basic Module Functions Power Module Turn-On StateAddr Dis Prot Error Messages Module Output ConnectorCase Of Trouble Mainframe FailureRuntime Error Messages Selftest Error MessagesMessages DisplaySynopsis Of Commands Basic Power Module CommandsGpib Controller MPS KeyboardPower Module Output Commands Function CommandPower Module Protection Commands Function Power Module Fixed-Mode Output CommandsPower Module Trigger Commands Function Power Module List-Mode Output CommandsControlling List-Mode Output Controlling TriggersUsing the RI/DFI Functions RI Remote Inhibit Input Changing The Power On StateDFI Discrete Fault Indicator Output Command DFI Output Commands FunctionCalibration Changing The Calibration PasswordEnabling Or Disabling The Calibration Function Performing a CalibrationEquipment Required Table A-2. Voltage Calibration ProcedureCalibrating Voltage Keyboard Entry Controller Entry † FunctionDisable the output Table A-3. Current Calibration ProcedureCalcurrlev MIN Calcurrlev MAXRecovering From a Lost Calibration Password Recovering The Factory Calibration ConstantsCalibration Error Messages Agilent Basic Calibration ProgramInitialize Power Supply Assign Power Supply Gpib AddressPassword is Optional only 10 ! Voltage Calibration ProgramPrint Current Calibration not Saved END ifElse Print Current Calibration CompleteConnecting The Keyboard Using The Agilent 66001A MPS KeyboardAgilent 66001A MPS Keyboard Meter Area Keyboard DescriptionAnnunciators Agilent 60001A MPS Keyboard System Keys  Letter Keys Changing or Entering Values Using The DisplayDisplaying Status Command Example Sending Scpi CommandsQuery Example Error Example Scpi Command Tree Agilent 60001A MPS Keyboard Addr IndexProt Unr AmpsShift SRQ Tlk Lsn ProtInit ScpiMeas VOLT?, 32 Outp Agilent Sales and Support Office Agilent Sales and Support OfficesManual Updates