Agilent Technologies 66001A manual Supplemental Characteristics, Output Characteristic Curve

Page 15

 

Table 1-2. Supplemental Characteristics (continued)

Parameter

Agilent Model Number and Parameter Value

Output Characteristic Curve:

Table 1-3. Replaceable Parts List

Description

Agilent Part No.

Cable assembly, mainframe GPIB

 

0.5 meters (1.6 ft)

10833D

1 meter (3.3 ft)

10833A

2 meters (6.6 ft)

10833B

4 meters (13.2 ft)

10833C

Cable assembly, mainframe serial link

5080-2148

Fuse, ac-line, 6 A

2110-0056

Output connector, standard

5060-3386

Output connector, with relays

5060-3387

Output connector converter board (converts

5060-3351

5060-3386 to 5060-3387)

 

Plug, mainframe INH/RFI input

1252-1488

Resistor, calibration

(see Appendix A)

General Information 15

Image 15
Contents Agilent Part No Microfiche Part No September USER’S GuideCertification Safety Summary Manufacturers Declaration Symbol DescriptionPrinting History HerstellerbescheinigungManufacturer’s Name and Address USAModel Numbers a 66000A Page Table of Contents Using the Agilent 66001A MPS Keyboard Basic Power Module CommandsItem Description Option DescriptionGeneral Information Accessories Readback Accuracy Specifications and Supplemental CharacteristicsProgramming Accuracy @ calibration temperature ± 5 C Output RatingsPerformance Specifications Parameter Supplemental Characteristics ParameterAgilent Model 66101A 66102A 66103A 66104A 66105A 66106A Remote Sensing Capability 66101A 66102A Agilent Model 66103A 66104A 66105A 66106ADownprogramming Monotonicity Gpib Interface Capabilities Recommended Calibration Interval Safety ComplianceDimensions WeightParameter Agilent Model Number and Parameter Value Supplemental CharacteristicsOutput Characteristic Curve Replaceable Parts List Description Agilent Part NoPage Installation SwitchesInspection Power Module Line Fuse and Switches Calibration Function Switches Remote Inhibit RI Function SwitchesSwitch Setting RI Action Display Function SwitchInstalling The Module In The Mainframe Connecting The LoadOutput Connector AWG No. *Ampacity Selecting the Proper Wire SizeOutput Connections Resistance Ω/ftVoltage Readback Remote Voltage SensingOutput Rating Output NoiseParallel Operation Voltprot Currlev MAX Outp on Outp OFFVoltlev Voltprot Currlev VoltlevCapacitive Loads Multiple LoadsOVP Considerations Connecting The ControllerBattery Charging Inductive LoadsModule Panel Display Power Module Front Panel DisplayTurn-On Checkout IntroductionPower Module Turn-On State Checking Basic Module FunctionsAddr Dis Prot Mainframe Failure Module Output ConnectorError Messages Case Of TroubleDisplay Selftest Error MessagesRuntime Error Messages MessagesMPS Keyboard Basic Power Module CommandsSynopsis Of Commands Gpib ControllerPower Module Fixed-Mode Output Commands CommandPower Module Output Commands Function Power Module Protection Commands FunctionControlling Triggers Power Module List-Mode Output CommandsPower Module Trigger Commands Function Controlling List-Mode OutputDFI Output Commands Function Changing The Power On StateUsing the RI/DFI Functions RI Remote Inhibit Input DFI Discrete Fault Indicator Output CommandPerforming a Calibration Changing The Calibration PasswordCalibration Enabling Or Disabling The Calibration FunctionKeyboard Entry Controller Entry † Function Table A-2. Voltage Calibration ProcedureEquipment Required Calibrating VoltageCalcurrlev MAX Table A-3. Current Calibration ProcedureDisable the output Calcurrlev MINAgilent Basic Calibration Program Recovering The Factory Calibration ConstantsRecovering From a Lost Calibration Password Calibration Error Messages10 ! Voltage Calibration Program Assign Power Supply Gpib AddressInitialize Power Supply Password is Optional onlyPrint Current Calibration Complete END ifPrint Current Calibration not Saved ElseUsing The Agilent 66001A MPS Keyboard Connecting The KeyboardAgilent 66001A MPS Keyboard Agilent 60001A MPS Keyboard Keyboard DescriptionMeter Area Annunciators System Keys  Letter Keys Using The Display Changing or Entering ValuesDisplaying Status Command Example Sending Scpi CommandsQuery Example Error Example Scpi Command Tree Agilent 60001A MPS Keyboard Amps IndexAddr Prot UnrShift SRQ Tlk Lsn ProtScpi InitMeas VOLT?, 32 Outp Agilent Sales and Support Office Agilent Sales and Support OfficesManual Updates