Sending SCPI Commands

As described in the power module Programming Guide, SCPI commands are organized into message units. The keyboard can only send one message unit at a time; you cannot combine message units. Also, optional headers within a command do not appear on the display. There are two ways to construct message units using the keyboard:

locate and append each SCPI header to the message unit with the Select keys, or

directly construct the message using only the first letter of each header with the letter keys.

The figure at the end of this appendix shows the SCPI command tree structure that is used by the keyboard. When the

command function is selected with thekey, the VOLTage command appears on the display for power supply modules.

The Select keys let you move up and down as well as across the various levels of the command tree. When numeric parameters are accessed with the Select keys, the value either defaults to zero or the last programmed value.

Letter keys let you directly access headers by typing the first letter of the header. Letter keys select headers by moving across the levels of the command tree. If more than one header starts with the same letter at a specific level in the command

tree, the first choice in that level is selected. Use the or key to select the command you want to use. You can also

use the ed letters to scroll through the available choices at the present command level that start with the shifted letter.

Command Example

The following examples show you how to use the Select keys or the letter keys to construct and send commands to the addressed module. In this example, the voltage protection level of a power supply module is being set to 7 volts.

46 Agilent 60001A MPS Keyboard

Image 46
Contents USER’S Guide Agilent Part No Microfiche Part No SeptemberCertification Safety Summary Herstellerbescheinigung Symbol DescriptionPrinting History Manufacturers DeclarationUSA Manufacturer’s Name and AddressModel Numbers a 66000A Page Table of Contents Basic Power Module Commands Using the Agilent 66001A MPS KeyboardOption Description Item DescriptionGeneral Information Accessories Output Ratings Specifications and Supplemental CharacteristicsProgramming Accuracy @ calibration temperature ± 5 C Readback AccuracySupplemental Characteristics Parameter Performance Specifications ParameterAgilent Model 66101A 66102A 66103A 66104A 66105A 66106A 66101A 66102A Agilent Model 66103A 66104A 66105A 66106A Remote Sensing CapabilityWeight Recommended Calibration Interval Safety ComplianceDimensions Downprogramming Monotonicity Gpib Interface CapabilitiesReplaceable Parts List Description Agilent Part No Supplemental CharacteristicsOutput Characteristic Curve Parameter Agilent Model Number and Parameter ValuePage Switches InstallationInspection Power Module Line Fuse and Switches Display Function Switch Remote Inhibit RI Function SwitchesSwitch Setting RI Action Calibration Function SwitchesConnecting The Load Installing The Module In The MainframeOutput Connector Resistance Ω/ft Selecting the Proper Wire SizeOutput Connections AWG No. *AmpacityRemote Voltage Sensing Voltage ReadbackOutput Noise Output RatingParallel Operation Voltprot Currlev Voltlev Outp OFFVoltlev Voltprot Currlev MAX Outp onMultiple Loads Capacitive LoadsInductive Loads Connecting The ControllerBattery Charging OVP ConsiderationsIntroduction Power Module Front Panel DisplayTurn-On Checkout Module Panel DisplayChecking Basic Module Functions Power Module Turn-On StateAddr Dis Prot Case Of Trouble Module Output ConnectorError Messages Mainframe FailureMessages Selftest Error MessagesRuntime Error Messages DisplayGpib Controller Basic Power Module CommandsSynopsis Of Commands MPS KeyboardPower Module Protection Commands Function CommandPower Module Output Commands Function Power Module Fixed-Mode Output CommandsControlling List-Mode Output Power Module List-Mode Output CommandsPower Module Trigger Commands Function Controlling TriggersDFI Discrete Fault Indicator Output Command Changing The Power On StateUsing the RI/DFI Functions RI Remote Inhibit Input DFI Output Commands FunctionEnabling Or Disabling The Calibration Function Changing The Calibration PasswordCalibration Performing a CalibrationCalibrating Voltage Table A-2. Voltage Calibration ProcedureEquipment Required Keyboard Entry Controller Entry † FunctionCalcurrlev MIN Table A-3. Current Calibration ProcedureDisable the output Calcurrlev MAXCalibration Error Messages Recovering The Factory Calibration ConstantsRecovering From a Lost Calibration Password Agilent Basic Calibration ProgramPassword is Optional only Assign Power Supply Gpib AddressInitialize Power Supply 10 ! Voltage Calibration ProgramElse END ifPrint Current Calibration not Saved Print Current Calibration CompleteConnecting The Keyboard Using The Agilent 66001A MPS KeyboardAgilent 66001A MPS Keyboard Annunciators Keyboard DescriptionMeter Area Agilent 60001A MPS Keyboard System Keys  Letter Keys Changing or Entering Values Using The DisplayDisplaying Status Sending Scpi Commands Command ExampleQuery Example Error Example Scpi Command Tree Agilent 60001A MPS Keyboard Prot Unr IndexAddr AmpsLsn Prot Shift SRQ TlkInit ScpiMeas VOLT?, 32 Outp Agilent Sales and Support Offices Agilent Sales and Support OfficeManual Updates