Agilent Technologies 66001A manual Performance Specifications Parameter

Page 12

Table 1-1. Performance Specifications (continued)

Parameter

Line Regulation (change in output voltage or current for any line change within ratings)

Voltage:

Current:

Transient Response Time (for output voltage to recover to within 100 mV of its previous level following a step change in load current that is up to 10% of the power module rated output current.

AC Input Ratings (selectable via module switch- see Chapter 2)

Nominal line voltage (Vac) 115 V switch setting 230 V switch setting

Frequency range:

Output Terminal Isolation (maximum, from output to the mainframe chassis ground):

Agilent Model

66101A

66102A

66103A

66104A

66105A

66106A

0.5 mV

0.5 mV

1 mV

2 mV

3 mV

5 mV

0.75 mA

0.5. mA

0.3 mA

0.1 mA

50 μA

30 μA

< 1 ms

87- 132 Vac

174- 250 Vac

47 - 63 Hz

±240 Vdc

Table 1-2. Supplemental Characteristics

Parameter

Output Programming Range (Maximum programmable values):

Agilent Model

66101A

66102A

66103A

66104A

66105A

66106A

Voltage:

Current:

OV Protection:

Average Programming Resolution

Voltage:

Current:

OV Protection:

OVP Accuracy (@ calibration temperature ±5° C):*

8.190 V

16.380 A

9.6V

2.4mV

4.6mA

50 mV

250 mV

20.475 V

7.678 A

24.0V

5.9mV

2.3mA

120 mV

500 mV

35.831 V

4.607 A

42.0V

10.4mV 1.4 mA 200 mV 800 mV

61.425 V

2.559 A

72.0V

18.0mV

0.75mA

375 mV

1 V

122.85V 1.280 A 144.0 V

36.0mV

0.39mA

750 mV

1.5V

204.75V 0.768 A 240.0 V

60.0mV

0.23mA

1.25V 2.5 V

*Factory calibration temp = 25° C

Readback Resolution Voltage:

Current:

0.305 mV

0.763 mV

1.335 mV

2.289 mV

4.577 mV

7.629 mV

0.587 mA

0.293 mA

0.169 mA

0.099 mA

0.049 mA

0.030 mA

Drift (Temperature Stability) (following a 30-minute warmup, change in output over 8 hours under constant line, load, and ambient temperature)

Voltage:

0.02% +

Current:

0.02% +

0.4mV 8 mA

1mV

5mA

2mV 2.5 mA

3mV 1.3 mA

6mV

0.63 mA

10mV 0.38 mA

12 General Information

Image 12
Contents USER’S Guide Agilent Part No Microfiche Part No SeptemberCertification Safety Summary Symbol Description Printing HistoryHerstellerbescheinigung Manufacturers DeclarationManufacturer’s Name and Address USAModel Numbers a 66000A Page Table of Contents Basic Power Module Commands Using the Agilent 66001A MPS Keyboard Item Description Option Description General Information Accessories Specifications and Supplemental Characteristics Programming Accuracy @ calibration temperature ± 5 COutput Ratings Readback AccuracyPerformance Specifications Parameter Supplemental Characteristics ParameterAgilent Model 66101A 66102A 66103A 66104A 66105A 66106A 66101A 66102A Agilent Model 66103A 66104A 66105A 66106A Remote Sensing CapabilityRecommended Calibration Interval Safety Compliance DimensionsWeight Downprogramming Monotonicity Gpib Interface CapabilitiesSupplemental Characteristics Output Characteristic CurveReplaceable Parts List Description Agilent Part No Parameter Agilent Model Number and Parameter ValuePage Installation SwitchesInspection Power Module Line Fuse and Switches Remote Inhibit RI Function Switches Switch Setting RI ActionDisplay Function Switch Calibration Function SwitchesInstalling The Module In The Mainframe Connecting The LoadOutput Connector Selecting the Proper Wire Size Output ConnectionsResistance Ω/ft AWG No. *AmpacityRemote Voltage Sensing Voltage ReadbackOutput Rating Output NoiseParallel Operation Outp OFF VoltlevVoltprot Currlev Voltlev Voltprot Currlev MAX Outp onMultiple Loads Capacitive LoadsConnecting The Controller Battery ChargingInductive Loads OVP ConsiderationsPower Module Front Panel Display Turn-On CheckoutIntroduction Module Panel DisplayPower Module Turn-On State Checking Basic Module FunctionsAddr Dis Prot Module Output Connector Error MessagesCase Of Trouble Mainframe FailureSelftest Error Messages Runtime Error MessagesMessages DisplayBasic Power Module Commands Synopsis Of CommandsGpib Controller MPS KeyboardCommand Power Module Output Commands FunctionPower Module Protection Commands Function Power Module Fixed-Mode Output CommandsPower Module List-Mode Output Commands Power Module Trigger Commands FunctionControlling List-Mode Output Controlling TriggersChanging The Power On State Using the RI/DFI Functions RI Remote Inhibit InputDFI Discrete Fault Indicator Output Command DFI Output Commands FunctionChanging The Calibration Password CalibrationEnabling Or Disabling The Calibration Function Performing a CalibrationTable A-2. Voltage Calibration Procedure Equipment RequiredCalibrating Voltage Keyboard Entry Controller Entry † FunctionTable A-3. Current Calibration Procedure Disable the outputCalcurrlev MIN Calcurrlev MAXRecovering The Factory Calibration Constants Recovering From a Lost Calibration PasswordCalibration Error Messages Agilent Basic Calibration ProgramAssign Power Supply Gpib Address Initialize Power SupplyPassword is Optional only 10 ! Voltage Calibration ProgramEND if Print Current Calibration not SavedElse Print Current Calibration CompleteUsing The Agilent 66001A MPS Keyboard Connecting The KeyboardAgilent 66001A MPS Keyboard Keyboard Description Meter AreaAnnunciators Agilent 60001A MPS Keyboard System Keys  Letter Keys Using The Display Changing or Entering ValuesDisplaying Status Sending Scpi Commands Command ExampleQuery Example Error Example Scpi Command Tree Agilent 60001A MPS Keyboard Index AddrProt Unr AmpsLsn Prot Shift SRQ TlkScpi InitMeas VOLT?, 32 Outp Agilent Sales and Support Offices Agilent Sales and Support OfficeManual Updates