Agilent Technologies 66001A Downprogramming Monotonicity Gpib Interface Capabilities, Dimensions

Page 14

Table 1-2. Supplemental Characteristics (continued)

Parameter

Trigger Response Time (average time for the output voltage or current to begin to change upon receipt of an external trigger)

With GPIB activity: Without GPIB activity:

Trigger Maximum Frequency (for repetitive external triggering, the maximum frequency for which the Trigger Response Time is valid)

With GPIB activity: Without GPIB activity:

Dwell Time

Programmable range:

Resolution:

Accuracy

With GPIB activity:

Without GPIB activity:

Downprogramming:

Monotonicity:

GPIB Interface Capabilities

Interface Signals (see IEEE 488.1):

Programming Language:

Serial Link Capabilities (maximum power modules sharing one GPIB primary address)

Agilent Model

66101A

66102A

66103A

66104A

66105A

66106A

5ms

3ms

75Hz

85Hz

10 ms to 65 s

2 ms

±5 ms

±2.5 ms

Active downprogrammer sinks approximately 10% of rated output current

Output is monotonic over entire rated voltage, current, and temperature range

AH1,C0,DC1, DT1,EI,LE4,PP0, RL1,SH1,SR1,TE6

SCPI (Standard Commands for Programmable Instruments)

16

Savable States

Nonvolatile memory locations: Volatile memory locations: Nonvolatile memory write cycles:

Recommended Calibration Interval:

Safety Compliance

Complies with:

Designed to comply with:

RFI Suppression (designed to comply with):

Dimensions

Width:

Height:

Depth

Pull tab inserted:

Pull tab extended:

Weight

Net:

Shipping:

10

5 (0 through 4)

5 (5 through 9)

40,000 (typical)

1 year

CSA 22.2 No.231 & IEC 348

UL 1244 & VDE 0411

FTZ 1046/84, Level B

48.3mm (1.9 in) 141.2 mm (5.6 in)

571.4mm (22.5 in)

606.4mm (23.8 in)

2.7kg (6 lb)

4.1kg (9 lb)

14 General Information

Image 14
Contents USER’S Guide Agilent Part No Microfiche Part No SeptemberCertification Safety Summary Herstellerbescheinigung Symbol DescriptionPrinting History Manufacturers DeclarationModel Numbers a 66000A Manufacturer’s Name and AddressUSA Page Table of Contents Basic Power Module Commands Using the Agilent 66001A MPS KeyboardGeneral Information Item DescriptionOption Description Accessories Output Ratings Specifications and Supplemental Characteristics Programming Accuracy @ calibration temperature ± 5 C Readback AccuracyAgilent Model 66101A 66102A 66103A 66104A 66105A 66106A Performance Specifications ParameterSupplemental Characteristics Parameter 66101A 66102A Agilent Model 66103A 66104A 66105A 66106A Remote Sensing CapabilityWeight Recommended Calibration Interval Safety ComplianceDimensions Downprogramming Monotonicity Gpib Interface CapabilitiesReplaceable Parts List Description Agilent Part No Supplemental CharacteristicsOutput Characteristic Curve Parameter Agilent Model Number and Parameter ValuePage Inspection InstallationSwitches Power Module Line Fuse and Switches Display Function Switch Remote Inhibit RI Function SwitchesSwitch Setting RI Action Calibration Function SwitchesOutput Connector Installing The Module In The MainframeConnecting The Load Resistance Ω/ft Selecting the Proper Wire SizeOutput Connections AWG No. *AmpacityRemote Voltage Sensing Voltage ReadbackParallel Operation Output RatingOutput Noise Voltprot Currlev Voltlev Outp OFFVoltlev Voltprot Currlev MAX Outp onMultiple Loads Capacitive LoadsInductive Loads Connecting The ControllerBattery Charging OVP ConsiderationsIntroduction Power Module Front Panel DisplayTurn-On Checkout Module Panel DisplayAddr Dis Prot Power Module Turn-On StateChecking Basic Module Functions Case Of Trouble Module Output ConnectorError Messages Mainframe FailureMessages Selftest Error MessagesRuntime Error Messages DisplayGpib Controller Basic Power Module CommandsSynopsis Of Commands MPS KeyboardPower Module Protection Commands Function CommandPower Module Output Commands Function Power Module Fixed-Mode Output CommandsControlling List-Mode Output Power Module List-Mode Output CommandsPower Module Trigger Commands Function Controlling TriggersDFI Discrete Fault Indicator Output Command Changing The Power On StateUsing the RI/DFI Functions RI Remote Inhibit Input DFI Output Commands FunctionEnabling Or Disabling The Calibration Function Changing The Calibration PasswordCalibration Performing a CalibrationCalibrating Voltage Table A-2. Voltage Calibration ProcedureEquipment Required Keyboard Entry Controller Entry † FunctionCalcurrlev MIN Table A-3. Current Calibration ProcedureDisable the output Calcurrlev MAXCalibration Error Messages Recovering The Factory Calibration ConstantsRecovering From a Lost Calibration Password Agilent Basic Calibration ProgramPassword is Optional only Assign Power Supply Gpib AddressInitialize Power Supply 10 ! Voltage Calibration ProgramElse END ifPrint Current Calibration not Saved Print Current Calibration CompleteAgilent 66001A MPS Keyboard Using The Agilent 66001A MPS KeyboardConnecting The Keyboard Annunciators Keyboard DescriptionMeter Area Agilent 60001A MPS Keyboard System Keys  Letter Keys Displaying Status Using The DisplayChanging or Entering Values Sending Scpi Commands Command ExampleQuery Example Error Example Scpi Command Tree Agilent 60001A MPS Keyboard Prot Unr IndexAddr AmpsLsn Prot Shift SRQ TlkMeas VOLT?, 32 Outp ScpiInit Agilent Sales and Support Offices Agilent Sales and Support OfficeManual Updates