Agilent Technologies 66001A manual Specifications and Supplemental Characteristics, Output Ratings

Page 11

When the power module is operated beyond either rated output, the performance specifications are not guaranteed, although typical performance may be good. Operation in quadrant 2 is limited to about 10% of the maximum rated positive output current. This allows the power module to sink current for more rapid downprogramming in the CV mode.

Specifications and Supplemental Characteristics

Table 1-1 lists the specifications of the power modules. Specifications are warranted over the specified temperature range. Table 1-2 lists the supplemental characteristics, which are not warranted but are descriptions of performance determined either by design or type testing.

 

Table 1-1. Performance Specifications

 

 

 

 

 

 

 

Agilent Model

 

 

Parameter

 

66101A

66102A

66103A

 

66104A

66105A

66106A

Specifications are warranted over the temperature range 0 to 55° C with a resistive load and the output connected for local sensing. Derate the output current 1% per °C from 40° C to 55°C.

Output Ratings

Voltage:

Current:

Power:

Programming Accuracy @ calibration temperature ± 5 °C)*

0 - 8 V

0 - 16 A

128 W

0 - 20 V

0 - 7.5 A

150 W

0 - 35 V

0 - 4.5 A

157.5 W

0 - 60 V

0 - 2.5 A

150 W

0 - 120 V

0 - 1.25 A

150 W

0 - 200 V

0 - 0.75 A

150 W

Voltage:

0.03% +

Current:

0.03% +

*Factory calibration temperature =

25°C

Ripple & Noise (from 20 Hz to 20 MHz with outputs ungrounded, or with either output terminal grounded)

3mV

6mA

8mV

3mA

13mV 2 mA

27mV

1.2 mA

54mV

0.6 mA

90mV

0.4 mA

Constant Voltage:

rms

Constant Voltage:

p-p

Constant Current:

rms

Readback Accuracy

With respect to actual output @ calibration temperature following self calibration.*

Voltage:

0.02% +

Current:

0.02% +

*Factory calibration temperature =

25°C

Load Regulation (change in output voltage or current for any load change within ratings)

2mV

5mV

8mA

2mV

6mA

3mV

7mV

4mA

5mV

3mA

5mV 10 mV

2mA

8mV

2mA

9mV 15 mV

1mA

16mV 1 mA

18mV

25mV 1 mA

32mV

0.6 mA

30mV

50mV 1 mA

54mV

0.3 mA

Voltage:

Current:

1mV

0.5 mA

1mV

0.2 mA

1mV

0.2 mA

2mV

0.1 mA

4mV

50μA

7mV

30μA

General Information 11

Image 11
Contents Agilent Part No Microfiche Part No September USER’S GuideCertification Safety Summary Manufacturers Declaration Symbol DescriptionPrinting History HerstellerbescheinigungModel Numbers a 66000A Manufacturer’s Name and AddressUSA Page Table of Contents Using the Agilent 66001A MPS Keyboard Basic Power Module CommandsGeneral Information Item DescriptionOption Description Accessories Readback Accuracy Specifications and Supplemental CharacteristicsProgramming Accuracy @ calibration temperature ± 5 C Output RatingsAgilent Model 66101A 66102A 66103A 66104A 66105A 66106A Performance Specifications ParameterSupplemental Characteristics Parameter Remote Sensing Capability 66101A 66102A Agilent Model 66103A 66104A 66105A 66106ADownprogramming Monotonicity Gpib Interface Capabilities Recommended Calibration Interval Safety ComplianceDimensions WeightParameter Agilent Model Number and Parameter Value Supplemental CharacteristicsOutput Characteristic Curve Replaceable Parts List Description Agilent Part NoPage Inspection InstallationSwitches Power Module Line Fuse and Switches Calibration Function Switches Remote Inhibit RI Function SwitchesSwitch Setting RI Action Display Function SwitchOutput Connector Installing The Module In The MainframeConnecting The Load AWG No. *Ampacity Selecting the Proper Wire SizeOutput Connections Resistance Ω/ftVoltage Readback Remote Voltage SensingParallel Operation Output RatingOutput Noise Voltprot Currlev MAX Outp on Outp OFFVoltlev Voltprot Currlev VoltlevCapacitive Loads Multiple LoadsOVP Considerations Connecting The ControllerBattery Charging Inductive LoadsModule Panel Display Power Module Front Panel DisplayTurn-On Checkout IntroductionAddr Dis Prot Power Module Turn-On StateChecking Basic Module Functions Mainframe Failure Module Output ConnectorError Messages Case Of TroubleDisplay Selftest Error MessagesRuntime Error Messages MessagesMPS Keyboard Basic Power Module CommandsSynopsis Of Commands Gpib ControllerPower Module Fixed-Mode Output Commands CommandPower Module Output Commands Function Power Module Protection Commands FunctionControlling Triggers Power Module List-Mode Output CommandsPower Module Trigger Commands Function Controlling List-Mode OutputDFI Output Commands Function Changing The Power On StateUsing the RI/DFI Functions RI Remote Inhibit Input DFI Discrete Fault Indicator Output CommandPerforming a Calibration Changing The Calibration PasswordCalibration Enabling Or Disabling The Calibration FunctionKeyboard Entry Controller Entry † Function Table A-2. Voltage Calibration ProcedureEquipment Required Calibrating VoltageCalcurrlev MAX Table A-3. Current Calibration ProcedureDisable the output Calcurrlev MINAgilent Basic Calibration Program Recovering The Factory Calibration ConstantsRecovering From a Lost Calibration Password Calibration Error Messages10 ! Voltage Calibration Program Assign Power Supply Gpib AddressInitialize Power Supply Password is Optional onlyPrint Current Calibration Complete END ifPrint Current Calibration not Saved ElseAgilent 66001A MPS Keyboard Using The Agilent 66001A MPS KeyboardConnecting The Keyboard Agilent 60001A MPS Keyboard Keyboard DescriptionMeter Area Annunciators System Keys  Letter Keys Displaying Status Using The DisplayChanging or Entering Values Command Example Sending Scpi CommandsQuery Example Error Example Scpi Command Tree Agilent 60001A MPS Keyboard Amps IndexAddr Prot UnrShift SRQ Tlk Lsn ProtMeas VOLT?, 32 Outp ScpiInit Agilent Sales and Support Office Agilent Sales and Support OfficesManual Updates