MGE UPS Systems 4000 RT user manual Life Cycle Monitoring LCM, Description, Get free offers

Page 30

6. Life Cycle Monitoring (LCM)

6.1 Description

This function, embedded in the UPS, displays messages, on screen and communication channels, at every important stage of the UPS’s life, allowing you to:

Get free offers

LOAD PROTECTED

 

x.xkVA / xxx% LOADED

 

LCM WARNING

 

SINGLE UPS

 

ESC

 

 

27

I

O

Press the "Enter" button (27) to display LCM warning details.

LCM warning details

Signification

 

 

3 MONTHS FREE

Get free offer after registration at: www.mgeups.com/lcm

WARRANTY EXTENSION

 

FOR PRODUCT

 

REGISTRATION

 

CONTACT MGE AT

 

www.mgeups.com/lcm

 

 

 

FREE STATISTIC

Get free offer after registration at: www.mgeups.com/lcm

FEATURE FOR

 

PRODUCT WEB

These statistics will allow you to have an accurate follow-up (on the display)

REGISTRATION

of the major environmental parameters of your installation:

CONTACT MGE AT

Autonomy, time with mains 2 out of tolerance, overloads number, load level

www.mgeups.com/lcm

in %, Battery ambient temperature, time on inverter, time on mains 2

 

 

Secure your installation power continuity

Anticipate maintenance actions thanks to automatically displayed warnings while displaying automatic warnings when maintenance actions need to be planned :

LCM warning details

Signification

 

 

FOR A SECURED

Entrust your product commissioning to MGE UPS SYSTEMS:

START-UP CALL MGE

MGE UPS SYSTEMS will check the installation according to local

CONTACT MGE AT

regulations, in respect of the state of the art.

www.mgeups.com/lcm

 

 

 

END OF WARRANTY

Get your product warranty extension, contacting MGE UPS SYSTEMS at:

SOON

www.mgeups.com/lcm

CONTACT MGE AT

 

www.mgeups.com/lcm

 

 

 

BATTERY CHECK RECOMMENDED

Battery is approaching its reliability end of life. Risk to reduce dramatically

CONTACT MGE AT

backup time

www.mgeups.com/lcm

 

 

 

TECHNICAL CHECK RECOMMENDED

Wearing parts of your product must be checked

CONTACT MGE AT

 

www.mgeups.com/lcm

 

 

 

ALARM OPERATION LIMITS

One of the following parameters is close to the limit of your product:

XXX

Autonomy, time with mains 2 out of tolerance, overloads load level in %,

CONTACT MGE AT

battery environment temperature

www.mgeups.com/lcm

 

 

 

34008030EN/AA - Page 30

Image 30
Contents Pulsar MX 34008030EN/AA Substances IntroductionEnvironmental protection PackingPictograms Contents Troubleshooting Technical specifications GlossaryStandard positions Dimensions H x W x D in mm / InchesPresentation Tower position Rack positionPulsar MX EXB RT optional battery module Rear panelsPulsar MX 4000 RT / 5000 RT Rack mounting kit Display and control panelOptions Telescopic rails, 639 mm to 1005 mmModularEasy Pulsar MX RT Pulsar MX RT ModularEasyPulsar MX RT Battery extensions for Pulsar MX RT Battery Integration SystemBattery extension cable 1,8 m / 6 ft Pulsar MX EXB RT Pulsar MX 4000 RT Min 29 min 53 minInstallation Unpacking and contents checkInternal battery connection Battery start-up Installation in tower position Installation in rack position UPS or battery module rack mounting optional rails required Communication ports Connection to the RS 232 communication portConnection to the communication port by relays Remote Power Off communication port Remote power off contact normally openRemote power off contact normally closed Recommended downstream protection Required protective devices and cable cross-sectionsRecommended upstream protection Required cable cross-sectionsConnection of input/output power cables on UPS terminals Always connect first the earthing wireConnection of IEC cables to output receptacles Final start-up sequence OperationInitial start-up UPS personalisationEquipments are supplied in ECO mode Normal modeEco mode Operating modesLow battery warning Operation on battery powerTransfer to battery power End of backup timeUPS shutdown Press the 0 button 28 more than 3sMaintenance menu Access to measurements and personalisation dataAccess to measurements Display organisationON/OFF settings Local settingsOutput settings UPS set-upMaintenance Personalisation using external softwareBattery settings But the operation is downgraded TroubleshootingTroubleshooting Leds 21 By the UPSIndication Diagnostic Correction Display Signification CorrectionDescription Secure your installation power continuityLife Cycle Monitoring LCM Get free offersReset or disable LCM Maintenance Hot swapping the power sub-moduleHot swapping the battery sub-module Return to normal operation Reconnecting the battery sub-moduleMaintenance Test positionTraining centre Hz training centreTechnical specifications AppendicesGlossary 34008030EN/AA 34008030EN/AA