MGE UPS Systems user manual Rear panels, Pulsar MX 4000 RT / 5000 RT

Page 8

1. Presentation

1.2 Rear panels

Pulsar MX 4000 RT / 5000 RT

SWITCHED

SWITCHED

GROUP 2

GROUP 1

7

8

9

11

PARALLEL

 

12

13

RS232 CONTACTS BAT NO. RPO

1

2

3

4

5

6

10

14

15

16

(1)Two groups of 2 programmable (10A) outlets for connection of equipment

(2)Groups of 4 (10A) outlets for connection of equipment

(3)Groups of 2 (16A) outlets for connection of equipment

(4)12A thermal switch

(5)20A thermal switch

(6)12A thermal switch

(7)Output terminal block

(8)Normal AC source terminal block

(9)Connector for additional battery module

(10)Slot for optional communication card

(11)Connector for parallel operation

(12)USB communication port

(13)RS232 communication port

(14)Communication port by relay

(15)Connector for automatic detection of battery module(s)

(16)Connector for Remote Power Off control (RPO)

Pulsar MX EXB RT (optional battery module)

18 180Vdc CONNECTORBATTERY

(17)Connectors for automatic detection of battery module(s)

(18)Connectors for battery modules (to the UPS or to the other battery modules)

(19)Battery circuit breaker

BATTERY BREAKER 50Adc

18

BATT. NO.

BATTERY CONNECTOR 180Vdc

17

19

34008030EN/AA - Page 8

Image 8
Contents Pulsar MX 34008030EN/AA Introduction Environmental protectionSubstances PackingPictograms Contents Troubleshooting Technical specifications GlossaryDimensions H x W x D in mm / Inches PresentationStandard positions Tower position Rack positionPulsar MX 4000 RT / 5000 RT Pulsar MX EXB RT optional battery moduleRear panels Display and control panel OptionsRack mounting kit Telescopic rails, 639 mm to 1005 mmPulsar MX RT ModularEasyPulsar MX RT Pulsar MX RT ModularEasy Battery Integration System Battery extension cable 1,8 m / 6 ftBattery extensions for Pulsar MX RT Pulsar MX EXB RT Pulsar MX 4000 RT Min 29 min 53 minInternal battery connection Battery start-up InstallationUnpacking and contents check Installation in tower position Installation in rack position UPS or battery module rack mounting optional rails required Connection to the communication port by relays Communication portsConnection to the RS 232 communication port Remote power off contact normally closed Remote Power Off communication portRemote power off contact normally open Required protective devices and cable cross-sections Recommended upstream protectionRecommended downstream protection Required cable cross-sectionsConnection of input/output power cables on UPS terminals Always connect first the earthing wireConnection of IEC cables to output receptacles Operation Initial start-upFinal start-up sequence UPS personalisationNormal mode Eco modeEquipments are supplied in ECO mode Operating modesOperation on battery power Transfer to battery powerLow battery warning End of backup timeUPS shutdown Press the 0 button 28 more than 3sAccess to measurements and personalisation data Access to measurementsMaintenance menu Display organisationLocal settings Output settingsON/OFF settings UPS set-upBattery settings MaintenancePersonalisation using external software Troubleshooting Troubleshooting Leds 21But the operation is downgraded By the UPSIndication Diagnostic Correction Display Signification CorrectionSecure your installation power continuity Life Cycle Monitoring LCMDescription Get free offersReset or disable LCM Hot swapping the battery sub-module MaintenanceHot swapping the power sub-module Reconnecting the battery sub-module MaintenanceReturn to normal operation Test positionTraining centre Hz training centreTechnical specifications AppendicesGlossary 34008030EN/AA 34008030EN/AA