Logical Printers
Follow the instructions below to substitute command strings:
1.From the print server’s internal Web page, select Admin Logical
Printers.
2.Select the PR1 Web page.
3.Enter the string 01 0A 02 0D 0A in the String Substitutions text field.
Hex Code | Explanation |
|
|
01 | length of the string you want to replace |
|
|
0A | the string you want to replace |
|
|
02 | length of the substitute string |
|
|
0D 0A | the substitute string |
|
|
4. Click the OK button.
This conversion is the default setting for logical printers PR5 through PR8.
Example:
Assume that you want to replace the UNIX/Linux New Line (hex 0A) with an Carriage Return/Line Feed (hex 0D 0A), and the printer command ECG1 (hex 1B 47 31) with ECY (hex 1B 59) for logical printer PR2.
Follow the instructions below to substitute command strings:
1.From the print server’s internal Web page, select Admin Logical
Printers.
2.Select the PR2 tab.
3.Enter the string 01 0A 02 0D 0A 03 1B 47 31 02 1B 59 in the String Substitutions text field.
Hex code | Explanation |
|
|
01 | length of the UNIX/Linux New Line command |
|
|
0A | the UNIX/Linux New Line command |
|
|
02 | length of the Carriage Return/Line Feed command |
|
|
0D 0A | the Carriage Return/Line Feed command |
|
|
03 | length of the printer command to replace |
|
|
1B 47 31 | the printer command to replace |
|
|
02 | length of the new printer command |
|
|
1B 59 | the new printer command |
|
|
Click the OK button.
Note:
Extensive use of string substitutions will naturally decrease the throughput rate of the Axis Network Print Server.
98 | AXIS 540+/AXIS 560 |