Transfer parameter table

 

 

 

 

 

 

 

Transfer object

Bank / CH

TYPE

Leading address

Transfer size

Status

 

 

 

 

 

 

 

 

 

 

 

 

flag

 

 

 

 

 

 

 

XW/YW register

0

H00

0 to 511 (T3H)

1 to 256

None

 

 

 

 

 

 

 

 

 

 

0 to 255 (T3)

 

 

 

 

 

 

 

 

 

 

 

 

0 to 63 (T2)

 

 

 

 

 

 

 

 

 

W register

0

H01

0 to 2047 (T3H)

1 to 256

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 to 1023 (T3/T2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LW register

0

H02

0 to 255 (T3H/T3/T2)

1 to 256

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RW register

0

H03

0 to 999 (T3H)

1 to 256

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 to 511 (T3)

 

 

 

 

 

 

 

 

 

 

 

 

0 to 127 (T2)

 

 

 

 

 

 

 

 

 

D register

0

H04

0 to 8191 (T3H/T3)

1 to 256

None

 

 

 

 

 

 

 

 

 

 

0 to 4095 (T2)

 

 

 

 

 

 

 

 

 

F register

0

H05

0 to 32767 (T3H)

1 to 256

None

 

 

 

 

 

 

 

 

 

 

0 to 8191 (T3)

 

 

 

 

 

 

 

 

 

 

 

 

0 to 1023 (T2)

 

 

Expanded F register

1 to 15

H05

0 to 8191 (T3H/T3/T2)

1 to 256

None

(IC memory card) *1

1 or 2

H06

0 to 65535 (bank 1) (T3H)

1 to 256

None

 

 

 

 

 

 

 

 

 

 

0 to 57343 (bank 2) (T3H)

 

 

S20 scan memory

1 or 2 *2

H10

0 to 1023 (T3H/T3/T2)

1 to 256

Yes *3

S20LP scan memory *4

1 or 2

H10

0 to 4095 (T3H)

1 to 256

None

EEPROM (D register)

0

H20

0 to 8191 (T3H/T3)

Source (read)

None

 

 

 

 

 

 

 

 

 

 

0 to 4095 (T2)

1 to 256

 

 

 

 

 

 

 

 

 

 

 

 

Destination (write)

 

 

 

 

 

 

 

 

 

 

 

 

1 to 128 (T3H)

 

 

 

 

 

 

 

 

 

 

 

 

1 to 64 (T3)

 

 

 

 

 

 

 

 

 

 

 

 

1 to 32 (T2)

 

*1) Two format types of the IC memory card is available. They are 8 k words/bank (type: H05) and 64 k words/bank (type: H06). Type H06 is available only in the T3H.

*2) Channel 1 (CH1) only for the T2.

*3) The status flag is created only when S20 is designated as transfer source.

*4) S20LP is available only with the T3H. The S20LP does not have the scan healthy map. Therefore status flag is not created for S20LP.

User’s Manual 57

Image 59
Contents USER’S Manual Important Information Hazard Classifications General InformationWiring Safety Precautions InstallationOperation Maintenance Safety Label Vac About This ManualTerminology T3 manualsContents Prosec T3H Section T3H Overview Introducing the T3H Differences between T3H and T3 Two types of T3H CPU modules are available T3H components CPU moduleStatus LEDs RAM/ROM switchMode control switch IC memory card slot Battery coverProgrammer port Computer link portExpansion interface module CPU T3H CPUCH1 CH2 Expansion cable Power supply moduleRack Following types of I/O modules are available O moduleAscii Data transmission moduleModule internal current consumption TOSLINE-S20LPRAS Specifications Functional specificationsSFC Instruction execution speed Dtst TeorTenr TestTrst SETRST TsetTAN PID2SIN COSInstruction execution speed cont’d Shown below Section Expanded Functions System operation Auto-RUN / Standby selection Timer interrupt intervalSaving the sampling trace condition Auxiliary register Expanded registersExternal I/O register Link register TimerLink Global Special register File registerSEND/RECV Expanded FunctionsTOSLINE-S20 Expanded Functions Starting register Expanded file register data read MRADR S T Expanded file register data Write MWExpanded Functions TOSLINE-S20LP loop support Ethernet support Instructions Double-word multiplication and division D∗ Expanded Functions DSV Essential PID PID3Algorithm Control block diagramParameter details ASV ← ISV OperationExpanded Functions Floating point essential PID FPID3 Digital filter PVn = 1− FT⋅ PVC+ FT⋅ PVn − Here ≤ FT ASV differential limit DSV 0 to 100 %/∆ t Data range +1 ⋅C Expanded Functions Expanded data transfer Xfer Type Transfer parameter tableCPU register ↔ Expanded F register IC memory card CPU register ↔ S20/S20LP scan memory CPU register ↔ Eeprom D register When the data writing address range exceeds page boundary MID Network data send SendExpanded Functions S20LP T3H self-station RW100 RW101 RW227 Network data receive Recv Expanded Functions H0A Expanded Functions Prosec T3H Toshiba Corporation