2. Expanded Functions

Inside the parameter (cont’d):

Status

S20LP

Ethernet

Abn

0: Normal complete

 

 

1: Error complete

 

Busy

0: Initial state

 

 

1: Transmission port busy

 

Status

0: Initial state

 

 

1: While send requesting

 

 

2: While waiting response

 

 

3: Complete

 

TermSTS

H00: Normal complete

 

 

H01: Register designation error

 

 

H02: Response time-out

 

 

H03: Parameter error

 

 

H04: Register write protect

 

 

H05: (Reserve)

 

 

H06: Module error (send time-out)

 

 

H07: No send channel

 

 

H08: Invalid station No.

 

 

H09: Transfer size error

 

 

H0A: Boundary error

 

 

H0B: Transmission error

Bit 7 indicates the error is occurred

 

H0C: I/O no answer error

whether self-station or target-station.

 

H0D: IC card designation error

0: Self-station

 

H0E: (Reserve)

1: Target-station

 

H0F: (Reserve)

 

Transmission error

When TermSTS is H0B, the error information is stored. (0 for other cases)

information

For detailed information, refer to the S20LP or EN311 manual.

Example

RW010

2

1

 

3

RW011

 

 

 

 

0

RW012

 

 

 

 

128

RW013

 

 

 

 

3

RW014

 

 

 

 

100

RW015

 

 

 

 

4

RW016

 

 

 

 

1000

RW017

 

 

 

 

10

RW050

 

 

 

 

 

0

0

1

0

 

0

RW051

 

 

 

 

0

S20LP, channel 1, target station No. is 3

Transfer size: 128 words

Self-station RW register

Leading address: RW100

Target-station D register

Leading address: D1000

Response time limit: 1 second

Send requesting

64 PROSEC T3H

Image 66
Contents USER’S Manual Important Information General Information Hazard ClassificationsSafety Precautions Installation WiringOperation Maintenance Safety Label T3 manuals About This ManualTerminology VacContents Prosec T3H Section T3H Overview Introducing the T3H Differences between T3H and T3 T3H components CPU module Two types of T3H CPU modules are availableRAM/ROM switch Mode control switchStatus LEDs Computer link port Battery coverProgrammer port IC memory card slotExpansion interface module T3H CPU CH1 CH2CPU Power supply module RackExpansion cable O module Following types of I/O modules are availableTOSLINE-S20LP Data transmission moduleModule internal current consumption AsciiSpecifications Functional specifications SFCRAS Instruction execution speed Test TeorTenr DtstTset SETRST TrstCOS PID2SIN TANInstruction execution speed cont’d Shown below Section Expanded Functions Timer interrupt interval System operation Auto-RUN / Standby selectionSaving the sampling trace condition Expanded registers External I/O registerAuxiliary register Timer Link registerLink Global File register Special registerExpanded Functions SEND/RECVTOSLINE-S20 Expanded Functions Expanded file register data read MR Starting registerExpanded file register data Write MW ADR S TExpanded Functions TOSLINE-S20LP loop support Ethernet support Instructions Double-word multiplication and division D∗ Expanded Functions Essential PID PID3 DSVControl block diagram AlgorithmParameter details Operation ASV ← ISVExpanded Functions Floating point essential PID FPID3 Digital filter PVn = 1− FT⋅ PVC+ FT⋅ PVn − Here ≤ FT ASV differential limit DSV 0 to 100 %/∆ t Data range +1 ⋅C Expanded Functions Expanded data transfer Xfer Transfer parameter table TypeCPU register ↔ Expanded F register IC memory card CPU register ↔ S20/S20LP scan memory CPU register ↔ Eeprom D register When the data writing address range exceeds page boundary Network data send Send MIDExpanded Functions S20LP T3H self-station RW100 RW101 RW227 Network data receive Recv Expanded Functions H0A Expanded Functions Prosec T3H Toshiba Corporation