Toshiba PROSEC T3H user manual Power supply module, Rack, Expansion cable

Page 19

1. T3H Overview

(3)Power supply module

The power supply module for the T3 is also used with the T3H. The following two types are available depending on power voltage.

Type

Rated voltage

Frequency

PS361

100 - 120 Vac/200 - 240 Vac (selectable)

50/60 Hz

PS332

24 Vdc

NOTE

For details, refer to the T3 User’s Manual.

(4)Rack

The rack (base board) for the T3 is also used with the T3H. The following four types are available.

Type

Number of slot

Use

BU31A

1 for PS, 1 for IF, 1 for CPU, 10 for I/O’s

For basic unit

BU315

1 for PS, 1 for IF, 1 for CPU, 5 for I/O’s

 

BU35B

1 for PS, 1 for IF, 11 for I/O’s

For expansion

BU356

1 for PS, 1 for IF, 6 for I/O’s

unit

NOTE

For details, refer to the T3 User’s Manual.

(5)Expansion cable

The following types of the expansion cables are available.

Type

Cable length

Remarks

CS3R5

0.5 m

For standard expansion.

CS301

1 m

With both-end connectors (50-pin)

CS302

2 m

 

CL3R5

0.5 m

For long-distance expansion.

CL301

1 m

With both-end connectors (68-pin)

CL305

5 m

 

CL310

10 m

 

CL320

20 m

 

CL340

40 m

 

NOTE

For details, refer to the T3 User’s Manual.

User’s Manual 17

Image 19
Contents USER’S Manual Important Information Hazard Classifications General InformationWiring Safety Precautions InstallationOperation Maintenance Safety Label Vac About This ManualTerminology T3 manualsContents Prosec T3H Section T3H Overview Introducing the T3H Differences between T3H and T3 Two types of T3H CPU modules are available T3H components CPU moduleMode control switch RAM/ROM switchStatus LEDs IC memory card slot Battery coverProgrammer port Computer link portExpansion interface module CH1 CH2 T3H CPUCPU Rack Power supply moduleExpansion cable Following types of I/O modules are available O moduleAscii Data transmission moduleModule internal current consumption TOSLINE-S20LPSFC Specifications Functional specificationsRAS Instruction execution speed Dtst TeorTenr TestTrst SETRST TsetTAN PID2SIN COSInstruction execution speed cont’d Shown below Section Expanded Functions System operation Auto-RUN / Standby selection Timer interrupt intervalSaving the sampling trace condition External I/O register Expanded registersAuxiliary register Link register TimerLink Global Special register File registerSEND/RECV Expanded FunctionsTOSLINE-S20 Expanded Functions Starting register Expanded file register data read MRADR S T Expanded file register data Write MWExpanded Functions TOSLINE-S20LP loop support Ethernet support Instructions Double-word multiplication and division D∗ Expanded Functions DSV Essential PID PID3Algorithm Control block diagramParameter details ASV ← ISV OperationExpanded Functions Floating point essential PID FPID3 Digital filter PVn = 1− FT⋅ PVC+ FT⋅ PVn − Here ≤ FT ASV differential limit DSV 0 to 100 %/∆ t Data range +1 ⋅C Expanded Functions Expanded data transfer Xfer Type Transfer parameter tableCPU register ↔ Expanded F register IC memory card CPU register ↔ S20/S20LP scan memory CPU register ↔ Eeprom D register When the data writing address range exceeds page boundary MID Network data send SendExpanded Functions S20LP T3H self-station RW100 RW101 RW227 Network data receive Recv Expanded Functions H0A Expanded Functions Prosec T3H Toshiba Corporation