Issue 10/06 | 6 Commissioning |
6.4.11Ramp function generator (RFG)
P1091 = ...
P1092 = ...
P1093 = ...
P1094 = ...
P1101 = ...
P1120 = ...
P1121 = ...
P1130 = ...
P1131 = ...
P1132 = ...
P1133 = ...
P1134 = ...
P1135 = ...
Skip frequency 1 (entered in Hz) | 0.00 Hz | fout | ||
Defines skip frequency 1, which avoids | ||||
effects of mechanical resonance and |
|
|
| |
suppresses frequencies within +/- p1101 |
|
|
| |
(skip frequency bandwidth). |
|
|
|
Skip frequency 2 | 0.00 Hz |
|
|
|
|
|
|
Skip frequency 3 | 0.00 Hz |
|
|
| p1101 |
|
|
|
|
|
|
|
|
| |
Skip frequency 4 | 0.00 Hz |
|
|
| Skip frequency |
|
|
|
|
| bandwidth |
|
| ||
|
|
|
| p1091 | fin |
|
|
Skip frequency bandwidth | 2.00 Hz |
|
|
|
|
| |
|
| Skip frequency |
|
| |||
(entered in Hz) |
|
|
|
|
|
|
|
| 10.00 s |
|
| f |
|
|
|
(enters the accelerating time in s) |
| p1082 |
|
|
|
| |
|
| (fmax) |
|
|
|
| |
|
|
| f1 |
|
|
|
|
| 10.00 s |
|
|
|
|
|
|
(enters the deceleration time in s) |
|
|
|
|
|
|
|
|
|
|
| p1120 | p1121 |
| t |
|
|
|
|
|
| ||
0.00 s |
| f |
|
|
|
| |
(entered in s) |
| f2 |
|
|
|
|
|
| 0.00 s |
|
|
|
|
| |
|
|
|
|
|
| ||
(entered in s) |
|
|
|
|
|
|
|
0.00 s |
|
|
|
|
|
| |
(entered in s) |
|
|
|
|
|
|
|
0.00 s | f1 |
|
|
|
|
| |
(entered in s) |
| P1130 | P1131 | P1132 | P1133 | t | |
|
| ||||||
Rounding type | 0 |
|
| tup | tdown |
|
|
|
|
|
|
|
|
0 | Continuous smoothing | The rounding times are recommended as | ||
1 | Discontinuous smoothing | |||
abrupt responses can be avoided therefore | ||||
|
| reducing stress and damage to the mechanical | ||
|
| system. | ||
|
| The | ||
|
| extended by the component of the rounding | ||
|
| ramps. | ||
OFF3 |
| 5.00 s |