Siemens 440 Fault messages and Alarm messages, Fault Significance, Alarm Significance

Page 77

Issue 10/06

7 Displays and messages

7.2Fault messages and Alarm messages

Fault

Significance

F0001

Overcurrent

F0002

Overvoltage

F0003

Undervoltage

F0004

Inverter Overtemperature

F0005

Inverter I2t

F0011

Motor Overtemperature I2t

F0012

Inverter temp. signal lost

F0015

Motor temperature signal lost

F0020

Mains Phase Missing

F0021

Earth fault

F0022

HW monitoring active

F0023

Output fault

F0024

Rectifier Over Temperature

F0030

Fan has failed

F0035

Auto restart after n

F0040

Automatic Calibration Failure

F0041

Motor Data Identification Failure

F0042

Speed Control Optimization Failure

F0051

Parameter EEPROM Fault

F0052

Power stack Fault

F0053

IO EEPROM Fault

F0054

Wrong IO Board

F0060

Asic Timeout

F0070

CB setpoint fault

F0071

USS (BOP link) setpoint fault

F0072

USS (COM link) setpoint fault

F0080

ADC lost input signal

F0085

External Fault

F0090

Encoder feedback loss

F0101

Stack Overflow

F0221

PID Feedback below min. value

F0222

PID Feedback above max. value

F0450

BIST Tests Failure

(Service mode only)

 

F0452

Belt Failure Detected

Alarm

Significance

A0501

Current Limit

A0502

Overvoltage limit

A0503

Undervoltage Limit

A0504

Inverter Overtemperature

A0505

Inverter I2t

A0506

Inverter Duty Cycle

A0511

Motor Overtemperature I2t

A0520

Rectifier Overtemperature

A0521

Ambient Overtemperature

A0522

I2C read out timeout

A0523

Output fault

A0535

Braking Resistor Hot

A0541

Motor Data Identification Active

A0542

Speed Control Optimization Active

A0590

Encoder feedback loss warning

A0600

RTOS Overrun Warning

A0700 -

CB warning 1

...

...

 

 

A0709

CB warning 9

A0710

CB communication error

A0711

CB configuration error

A0910

Vdc-max controller de-activated

A0911

Vdc-max controller active

A0912

Vdc-min controller active

A0920

ADC parameters not set properly

A0921

DAC parameters not set properly

A0922

No load applied to inverter

A0923

Both JOG Left and Right are requested

A0952

Belt Failure Detected

A0936

PID Autotuning Active

MICROMASTER 440

77

Operating Instructions (Compact)

Image 77
Contents User Documentation Operating Instructions Compact Issue 10/06Issue 10/06 Contents Contents Issue 10/06 Frame Drilling Dimensions Tightening Torque Size Mounting dimensionsClearance distances for mounting BoltsInput voltage range Technical SpecificationsTightening torques for Power terminals Lbf.in Weight Lbs 12,5Order No 6SE6440 26,5Output Power KVA Weight LbsWeight 1BA1 5BA12AD23 2AD24 Power terminals Lbf.in2AD27 2AD31Input Cable, max Mm2 For UL specified Input Cable, min Mm2Output Cable, min Mm2 Output Cable, max Mm24/0 or 300 or 400 or 500 or 1/0 2/0 95 or 150 or 185 or 240 or350 or 4/0 Recommended Fuse5CA1 Order No 6SE6440 2UE17 2UE21 2UE22 2UE24 2UE25 2UE27 2UE31Frame Size a Power TerminalsRemoving front covers Frame Sizes B and C Frame Sizes B and CRemoving front covers Frame Sizes D and E Frame Sizes D and ERemoving front covers Frame Size F Frame Size FRemoving front covers Frame Sizes FX and GX Frame Sizes FX and GXConnection terminals for Frame Sizes a F Connection overview for Frame Size FX Connection overview for Frame Size GX Control terminals of Micromaster Control terminalsTerminal Designation Function Frame sizes Block diagramTo F FX and GXPre-assignment of the inputs 50/60 Hz DIP switchInput/Output Parameter FunctionAOP at the BOP link AOP at the COM link PC frequency inverter connecting setEstablishing communications AOP as control unit Bus interface CBParameter / Terminal AOP on BOP link AOP on COM link DeviceNet CANopenButtons and their Functions Step Result on the display Quick commissioning Selection of command source Rated motor powerRated motor voltage Rated motor currentMin. frequency Selection of frequency setpointMax. frequency Ramp-up timeEnd of the quick commissioning/drive setting Control modeSelection of torque setpoint Select motor data identificationMotor data identification Factory setting Ambient motor temperature entered in CMagnetizing current Select motor data identification with P1910 =Determining the magnetizing current Quick commissioning routineMotor data identification routine Serial Interface USS Selection of command sourceCommissioning the application Digital input DIN Function digital input Possible SettingsFunction digital input Debounce time for digital inputsDigital outputs Dout Common Settings ClosedBI Function of digital output CO/BO State of digital outputsCommon settings BI Disable additional setpointSelection of frequency setpoint Example P1000 =Analog input ADC Analog output DAC Setpoint memory of the MOP Motor potentiometer MOPInhibit negative MOP setpoints Setpoint of the MOPFixed frequency FF JOG frequency right 10 JOGJOG frequency left JOG ramp-up timeRamp function generator RFG Reference/limit frequencies Delay, fan shutdown Inverter temperature warningInverter protection Motor protectionAlarm threshold, motor overtemperature Motor temperature sensorInverter temperature reaction Motor overload factor %Encoder Acceleration boost entered in % 16 V/f controlContinuous boost entered in % Programmable V/f freq Coord Starting boost entered in %Programmable. V/f volt .0 Hz Programmable V/f freq .0 HzLimitations Field-orientated controlSensorless vector control Slvc 17.1P1750 = Operation directly after an on commandControl word of motor model Zero crossingVector control with encoder VC 17.2Filter time for act. speed Gain speed controllerSupplementary torque setpoint Frequent settingsP1511= CI Supplementary torque setpointAutomatic restart Converter-specific FunctionsFlying start Motor size Brake type Opening time ms Closing time ms Holding brake enableHolding brake BI Fct digital output Holding brake release delay entered in sInverting digital Outputs Holding time after ramp-down entered in sP1230 = P1232 = P1233 = DC brakeBI Enabling the DC brake DC braking current entered in %Compound braking current entered in % Compound brakingDC braking start frequency entered in Hz Vdc controller Dynamic braking18.7 Load torque monitoring P2182 PID controller P2264 CI PID feedback Controller structuresParameter Parameter text Example PID cancer control Parameter Parameter text Setting MeaningPositioning down ramp Free function blocks FFB Enable FFBsP2800 = P2801 = P2802 = Activate FFBsInput parameters Output parameters Setting parameters Data sets Command data set CDSP0820 = P0821 = Drive data set DDSDrive data set DDS bit BI DDS bitDIN Diagnostic parameters CO Actual frequency CO/BO Control wordCO Act. output current limit CO Act. output voltageCO Selected frequency setpoint R1079R1114 R1170 CO Freq. setpoint after dir. ctrlSeries commissioning Parameter reset of factory settingFactory reset LED status display Displays and messagesAlarm Significance Fault messages and Alarm messagesFault Significance Regional Contacts Online Service & SupportCentral Technical Support Internet Address