Foundry Networks FGS624P Position State Meaning, Gbps Port LEDs, POE Port LEDs, Power Supply LEDs

Page 19

 

 

 

 

 

 

Product Overview

 

 

 

 

Table 2.2: LEDs (Continued)

 

 

 

 

 

 

 

 

LED

 

Position

 

State

Meaning

 

 

 

 

 

 

 

 

 

Lnk/Act

 

Bottom left

 

On

The link is up.

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

The link is down.

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking

The port is transmitting and/or receiving

 

 

 

 

 

 

traffic.

 

 

 

 

 

 

 

 

 

10 Gbps Port LEDs

 

 

 

 

 

 

 

 

 

 

 

 

 

Lnk

 

Located beside

 

On

The port is connected.

 

 

 

the 10-GbE

 

 

 

 

 

 

 

 

Off

No fiber port connection exists or the link

 

 

 

port.

 

 

 

 

 

 

is down.

 

 

 

This is the top-

 

 

 

 

 

 

 

 

 

 

 

 

most LED.

 

 

 

 

 

 

 

 

 

 

 

 

 

Act

 

Located beside

 

On or Blinking

Traffic is being transmitted and/or received

 

 

 

the 10-GbE

 

 

on the fiber port.

 

 

 

port.

 

 

 

 

 

 

 

 

Off

No traffic is being transmitted or received

 

 

 

This is the

 

 

 

 

 

 

on the fiber port.

 

 

 

bottom-most

 

 

 

 

 

 

 

LED.

 

 

 

 

 

 

 

 

 

 

 

 

 

POE Port LEDs

 

 

 

 

 

 

 

 

 

 

 

 

 

POE

 

Located along

 

On (Green)

The port is enabled, a power-consuming

 

 

 

the bottom of

 

 

device has been detected, and the

 

 

 

the copper ports

 

 

module is supplying power to the device.

 

 

 

Left for upper

 

 

 

 

 

 

 

 

Off

The port is not providing in-line power.

 

 

 

port

 

 

 

 

 

 

 

Right for lower

 

 

 

 

 

 

 

port

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply LEDs

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

Right-most LED

 

On

The device is powered on and has enough

 

 

 

beneath the

 

 

power to operate.

 

 

 

console port

 

 

 

 

 

 

 

 

Off

The device is not powered on, or has

 

 

 

 

 

 

 

 

 

 

 

been powered on but does not have

 

 

 

 

 

 

sufficient power to operate.

 

 

 

 

 

 

 

 

 

PS1

 

Left-most LED

 

On

Power supply 1 is installed and is

 

 

 

beneath the

 

 

functioning normally. Power supply 1 is

 

 

 

console port

 

 

located in the right-hand bay (when you

 

 

 

 

 

 

are facing the rear of the device).

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

Power supply 1 is not installed or is not

 

 

 

 

 

 

providing power.

 

 

 

 

 

 

 

 

 

PS2

 

Middle LED

 

On

Power supply 2 is installed and is

 

 

 

beneath the

 

 

functioning normally. Power supply 2 is

 

 

 

console port

 

 

located in the left-hand bay (when you are

 

 

 

 

 

 

facing the rear of the device).

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

Power supply 2 is not installed or is not

 

 

 

 

 

 

providing power.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

September 2007

© 2007 Foundry Networks, Inc.

2 - 11

Image 19
Contents FGS Release Page Contents Hecking C Onnectivity Hardware Specifications Egulatory S Tatements Audience Chapter About This GuideIntroduction What’s Included in This Edition?Warranty Coverage How to Get HelpRelated Publications Product Overview Chapter Product OverviewHardware Features Software FeaturesFGS624P and FGS624P-POE FGS648P and FGS648P-POE FGS624XGP and FGS624XGP-POEShows the FGS648P and FGS648P-POE Control FeaturesOptional 2-port 10-GbE Module port 49 Serial Management Interface Console PortNetwork Interfaces Reset ButtonNetwork Interfaces Show Media Description Port 10-GbE Module 10/100/1000 Mbps Ports Port 10-GbE Hybrid Interface Module Release Port CX4 Module Release 10GbE XFP Transceiver FGS624XGP Models Only CX4 10Gbps XFP Transceiver 10GbE XG and CX4 Module100/1000 Fiber Port LEDs LEDs for Network Interfaces and Power SuppliesLEDs Position State Meaning 10/100/1000 Copper Port LEDsPOE Port LEDs Power Supply LEDsPosition State Meaning Gbps Port LEDsFiber Optic Modules Power SuppliesPosition State Meaning Stacking LEDs Cooling System and Fans Power Specifications for POESeptember General Requirements Chapter Installing the FastIron GS ChassisPackage Contents Unpacking a SystemSummary of Installation Tasks Where to Find More Information Summary of Installation TasksSummary of Installation Tasks Installation PrecautionsGeneral Precautions Lifting PrecautionsPower Supply Precautions Installing an Additional Power Supply Preparing the Installation SiteCabling Infrastructure Installation Location Power supply locking screw Latches Installing an AC Power SupplyRetaining Bale AC Power Cord Installing a DC Power Supply Ground screw Negative terminal screw Ground Desktop Installation Installing the DeviceRack Mount Installation Attaching the Short Mounting Brackets Installing the Brackets and Mounting the Device Wall Mount InstallationInstall top screws Install device Powering On the SystemVerifying Proper Operation Powering Off the SystemLEDs for Power Observing the Power Status LEDsAttaching a PC or Terminal FastIron FastIron-PREM DB-9 to DB-9 Assigning Permanent Passwords Chapter Connecting Network Devices Checking ConnectivityRecovering from a Lost Password Devices Running Layer 2 Software Configuring IP AddressesCable Specifications Connecting Network DevicesConnecting to Ethernet or Fast Ethernet Hubs Automatic MDI/MDIX Detection Connecting to Workstations, Servers, or RoutersConnecting a Network Device to a Fiber Port Installing a Fiber Optic ModuleCabling a Fiber Optic Module Testing ConnectivityCleaning the Fiber-Optic Connectors Pinging an IP AddressNetwork Connection-Related LED States Observing LEDsDesired Meaning Abnormal Meaning/Action State Command Syntax Troubleshooting Network ConnectionsUsing Virtual Cable Testing to Diagnose a Cable Configuration NotesThis Line Viewing the Results of the Cable AnalysisCable Statistics Displays September Chapter Managing the FastIron GS Chassis Managing Temperature SettingsUsing the Temperature Sensor Displaying the TemperatureChanging the Temperature Warning Level Displaying Temperature MessagesDisplaying Management Module CPU Usage Changing the Chassis Temperature Polling IntervalRemoving MAC Address Entries September Chassis Specifications Chapter Hardware SpecificationsPower Supply Specifications Storage Environment Chassis SpecificationsPhysical Dimensions and Weight Environmental ConsiderationsRegulatory Compliance CoolingChassis Regulatory Compliance Description Certifications Mean Time Between Failure Power Source InterruptionsPower Supply Draw Specifications Model Typical Maximum Power Draw SpecificationsSerial Console Port Pinouts Pinouts and Signalling10/100 and Gigabit Port Pinouts Lists the pin assignment and signalling for 10/100/100 portsLC connector 62.5/125 200 For SFP module LC connector 1530.33 Up to For XFP module 1561.42 nm 80 km Power Supply SpecificationsPower Cords WarrantyKey features 10 Maximum Power Supply Consumption for FGS Models FGS624 Power Supply ConsumptionFGS648 11 Input Connector for Power Supplies Input Connector and PlugPower Supply Input Connector Properties 13 Safety Warning Labels on Power Supplies Safety WarningsOutput Specifications Electrical SpecificationsReplacing a Power Supply Hardware Maintenance ScheduleChapter Maintaining the FastIron GS Hardware Determining Which Power Supply Failed Installation Precautions and WarningsAC Power Supplies Locking screw Removing an AC Power SupplyInstalling an AC Power Supply DC Power Supplies Shows a front view of the DC power supply Removing a DC Power SupplyInstalling a DC Power Supply Ground Installing a 2-port 10-GbE Module Installing or Replacing a 2-port 10-GbE ModuleRemoving a 2-port 10-GbE Module Installing a 2-port 10-GbE Module Installing or Replacing a POE Daughter CardRemoving the Screws for the Top Cover Disassembling the ChassisRemoving the Top Cover Installing a POE Daughter CardPOE Daughter Card POE Daughter Cards Re-assembling the ChassisRemoving a Fiber Optic Module Replacing a Fiber Optic ModuleInstalling a New Fiber Optic Module Cleaning the Fiber-Optic ConnectorsCabling a Fiber Optic Module Status Value Description Digital Optical MonitoringShow optic port/slotnumber CLI CommandsNo optical-monitor alarm interval Supported MediaJapan Appendix a Regulatory StatementsIndustry Canada Statement Europe and AustraliaEnglish Translation of above statement Appendix B Foundry Networks, Inc Page Foundry Networks, Inc Page September Page September