Foundry Networks FGS648P-POE, FGS624P-POE, FGS624XGP-POE manual September

Page 94

FastIron GS Compact Layer 2 Switch Hardware Installation Guide

Warnings

A warning calls your attention to a possible hazard that can cause injury or death. The following are the warnings used in this manual.

"Achtung" weist auf eine mögliche Gefährdung hin, die zu Verletzungen oder Tod führen können. Sie finden die folgenden Warnhinweise in diesem Handbuch:

Un avertissement attire votre attention sur un risque possible de blessure ou de décès. Ci-dessous, vous trouverez les avertissements utilisés dans ce manuel.

Una advertencia le llama la atención sobre cualquier posible peligro que pueda ocasionar daños personales o la muerte. A continuación se dan las advertencias utilizadas en este manual.

WARNING: The procedures in this manual are for qualified service personnel.

ACHTUNG: Die Verfahren in diesem Handbuch sind nur für qualifiziertes Wartungspersonal gedacht.

AVERTISSEMENT: Les procédures décrites dans ce manuel doivent être effectuées par le personnel de service qualifié uniquement.

ADVERTENCIA: Los procedimientos de este manual se han hecho para personal de servicio cualificado.

WARNING: All fiber optic interfaces use Class 1 lasers.

ACHTUNG: Alle Glasfaser-Schnittstellen verwenden Laser der Klasse 1.

AVERTISSEMENT: Toutes les interfaces en fibres optiques utilisent des lasers de classe 1.

ADVERTENCIA: Todas las interfaces de fibra óptica utilizan láser de clase 1.

WARNING: Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over.

ACHTUNG: Stellen Sie sicher, dass das Gestell oder der Schrank für die Unterbringung des Geräts auf angemessene Weise gesichert ist, so dass das Gestell oder der Schrank nicht wackeln oder umfallen kann.

AVERTISSEMENT: Vérifiez que le bâti ou le support abritant le dispositif est bien fixé afin qu'il ne devienne pas instable ou qu'il ne risque pas de tomber.

ADVERTENCIA: Verifique que el bastidor o armario que alberga el instrumento está asegurado correctamente para evitar que pueda hacerse inestable o que caiga.

WARNING: Mount the devices you install in a rack or cabinet as low as possible. Place the heaviest

device at the bottom and progressively place lighter devices above.

ACHTUNG: Montieren Sie die Geräte im Gestell oder Schrank so tief wie möglich. Platzieren Sie das schwerste Gerät ganz unten, während leichtere Geräte je nach Gewicht (je schwerer desto tiefer) darüber untergebracht werden.

AVERTISSEMENT: Montez les dispositifs que vous installez dans un bâti ou support aussi bas que possible. Placez le dispositif le plus lourd en bas et le plus léger en haut, en plaçant tous les dispositifs progressivement de bas en haut du plus lourd au plus léger.

ADVERTENCIA: Monte los instrumentos que instale en un bastidor o armario lo más bajos posible. Ponga el instrumento más pesado en la parte inferior y los instrumentos progresivamente más livianos más arriba.

B - 6

© 2007 Foundry Networks, Inc.

September 2007

Image 94
Contents FGS Release Page Contents Hecking C Onnectivity Hardware Specifications Egulatory S Tatements What’s Included in This Edition? Chapter About This GuideIntroduction AudienceWarranty Coverage How to Get HelpRelated Publications Chapter Product Overview Product OverviewHardware Features Software FeaturesFGS624P and FGS624P-POE FGS624XGP and FGS624XGP-POE FGS648P and FGS648P-POEControl Features Shows the FGS648P and FGS648P-POESerial Management Interface Console Port Optional 2-port 10-GbE Module port 49Network Interfaces Reset ButtonNetwork Interfaces Show Media Description 10/100/1000 Mbps Ports Port 10-GbE ModulePort 10-GbE Hybrid Interface Module Release Port CX4 Module Release10GbE XFP Transceiver FGS624XGP Models Only 10GbE XG and CX4 Module CX4 10Gbps XFP TransceiverPosition State Meaning 10/100/1000 Copper Port LEDs LEDs for Network Interfaces and Power SuppliesLEDs 100/1000 Fiber Port LEDsGbps Port LEDs Power Supply LEDsPosition State Meaning POE Port LEDsFiber Optic Modules Power SuppliesPosition State Meaning Stacking LEDs Power Specifications for POE Cooling System and FansSeptember Unpacking a System Chapter Installing the FastIron GS ChassisPackage Contents General RequirementsSummary of Installation Tasks Summary of Installation Tasks Where to Find More InformationLifting Precautions Installation PrecautionsGeneral Precautions Summary of Installation TasksPower Supply Precautions Installing an Additional Power Supply Preparing the Installation SiteCabling Infrastructure Installation Location Installing an AC Power Supply Power supply locking screw LatchesRetaining Bale AC Power Cord Installing a DC Power Supply Ground screw Negative terminal screw Ground Desktop Installation Installing the DeviceRack Mount Installation Attaching the Short Mounting Brackets Wall Mount Installation Installing the Brackets and Mounting the DevicePowering On the System Install top screws Install devicePowering Off the System Verifying Proper OperationLEDs for Power Observing the Power Status LEDsAttaching a PC or Terminal FastIron FastIron-PREM DB-9 to DB-9 Chapter Connecting Network Devices Checking Connectivity Assigning Permanent PasswordsRecovering from a Lost Password Configuring IP Addresses Devices Running Layer 2 SoftwareCable Specifications Connecting Network DevicesConnecting to Ethernet or Fast Ethernet Hubs Installing a Fiber Optic Module Connecting to Workstations, Servers, or RoutersConnecting a Network Device to a Fiber Port Automatic MDI/MDIX DetectionPinging an IP Address Testing ConnectivityCleaning the Fiber-Optic Connectors Cabling a Fiber Optic ModuleNetwork Connection-Related LED States Observing LEDsDesired Meaning Abnormal Meaning/Action State Configuration Notes Troubleshooting Network ConnectionsUsing Virtual Cable Testing to Diagnose a Cable Command SyntaxThis Line Viewing the Results of the Cable AnalysisCable Statistics Displays September Displaying the Temperature Managing Temperature SettingsUsing the Temperature Sensor Chapter Managing the FastIron GS ChassisDisplaying Temperature Messages Changing the Temperature Warning LevelDisplaying Management Module CPU Usage Changing the Chassis Temperature Polling IntervalRemoving MAC Address Entries September Chassis Specifications Chapter Hardware SpecificationsPower Supply Specifications Environmental Considerations Chassis SpecificationsPhysical Dimensions and Weight Storage EnvironmentRegulatory Compliance CoolingChassis Regulatory Compliance Description Certifications Power Source Interruptions Mean Time Between FailurePower Draw Specifications Power Supply Draw Specifications Model Typical MaximumPinouts and Signalling Serial Console Port PinoutsLists the pin assignment and signalling for 10/100/100 ports 10/100 and Gigabit Port PinoutsLC connector 62.5/125 200 For SFP module Warranty Power Supply SpecificationsPower Cords LC connector 1530.33 Up to For XFP module 1561.42 nm 80 kmKey features 10 Maximum Power Supply Consumption for FGS Models FGS624 Power Supply ConsumptionFGS648 11 Input Connector for Power Supplies Input Connector and PlugPower Supply Input Connector Properties Safety Warnings 13 Safety Warning Labels on Power SuppliesElectrical Specifications Output SpecificationsReplacing a Power Supply Hardware Maintenance ScheduleChapter Maintaining the FastIron GS Hardware Determining Which Power Supply Failed Installation Precautions and WarningsAC Power Supplies Removing an AC Power Supply Locking screwInstalling an AC Power Supply DC Power Supplies Removing a DC Power Supply Shows a front view of the DC power supplyInstalling a DC Power Supply Ground Installing a 2-port 10-GbE Module Installing or Replacing a 2-port 10-GbE ModuleRemoving a 2-port 10-GbE Module Installing or Replacing a POE Daughter Card Installing a 2-port 10-GbE ModuleDisassembling the Chassis Removing the Screws for the Top CoverInstalling a POE Daughter Card Removing the Top CoverPOE Daughter Card Re-assembling the Chassis POE Daughter CardsReplacing a Fiber Optic Module Removing a Fiber Optic ModuleInstalling a New Fiber Optic Module Cleaning the Fiber-Optic ConnectorsCabling a Fiber Optic Module Digital Optical Monitoring Status Value DescriptionSupported Media CLI CommandsNo optical-monitor alarm interval Show optic port/slotnumberEurope and Australia Appendix a Regulatory StatementsIndustry Canada Statement JapanEnglish Translation of above statement Appendix B Foundry Networks, Inc Page Foundry Networks, Inc Page September Page September