Ricoh G413 operating instructions To change the Skew tab settings

Page 34

VRS Getting Started Guide

!To change the Skew tab settings

1 From the VRS Interactive Properties dialog box, select the Skew tab.

2Adjust the movable angle control arm until the image is straight:

a Use the mouse to select the vertical arm. When selected, the pointer changes to a hand icon.

b Move the arm counter-clockwise to rotate the image to the left, or clockwise to rotate it to the right. The Angle setting changes as the image rotates; the valid range is -45 degrees to 45 degrees.

3In the Angle box, you have two ways to adjust the Angle setting:

a Place your cursor in the Angle box, click the arrows to review the list of settings, and click your selection.

b Type a value for the correction angle directly into the Angle box. The valid range for the angle is -45 degrees to 45 degrees.

4Using the Fine Angle Adjustment Slider, you can fine-tune the deskew angle in single degree, or partial degree, increments, as follows:

a By moving the slider all the way to the left, you select a complete one-degree, counter- clockwise angle adjustment.

b By moving the slider all the way to the right, you select a complete one-degree, clockwise angle adjustment.

c By moving the slider to a position in between the leftmost or rightmost setting, you select an angle shift that is less than a full degree. Each line on the slider scale represents 5 percent of one degree.

30

Kofax Image Products

Image 34
Contents Ricoh Copyright Contents VRS Getting Started Guide Introduction Product OverviewSystem Requirements VRS Product PackageScanner Install the Software InstallationTo install the VRS software Setup Complete Dialog Box Precautions Install the Adrenaline Hardware AcceleratorCompatibility with Current Accelerators and Engines Configure the Accelerator Windows Connect PC to ScannerConfigure the Accelerator Windows NT Kofax Configuration Manager KCM Dialog BoxAttach Your Scanner To connect the scanner to your PCStarting VirtualReScan To start VRSFirst Time Calibration Opening the VRS MenuTo open the VRS menu Select Source, Properties VRS Getting Started Guide Preview ConfigureReset ProfileDefining Exception Conditions CauseContrast Out of Range Threshold Selecting the ThresholdBrightness Out of Range Threshold Missing Corner ThresholdErrors Tab Selecting an ActionError Description Action OptionsTo define exception condition parameters Action Type DescriptionIgnore manual mode only Rescan manual mode onlyVRS manual mode only Auto Resolve check boxStop Every Selecting a ModeStop on Errors Stop on FirstUpdating Image Properties VRS Viewer with the VRS Interactive Properties Dialog BoxUsing the Zoom Menu to adjust the view Using the VRS ViewerUsing mouse buttons to adjust the view Using the VRS Interactive Properties Dialog Box VRS Interactive Properties Dialog Box TabsVRS Interactive Properties Dialog Box Buttons Brightness and Contrast Visual Markers Using the Clarity TabBrightness and Contrast Black LinesDotted Red Lines To change the Clarity settingsBlue Rectangle GammaUsing the Noise Tab To change the Noise settingsVRS Getting Started Guide Using the Skew Tab Skew TabTo change the Skew tab settings Using the Profiles Tab To set up a profileTo change the active profile To remove a profile from the Available Profiles listAutomatic Deskew Using the Options TabImage Crop VRS Refresh Intelligent Contrast Adjustment / Brightness AdjustmentAccelerated Scanning To change the selections on the Options tabUsing the Analysis Tab Analysis TabUsing the About Tab About TabPreviewing Images To preview an imageResetting VRS To reset the VRS configurationTechnical Support Headquarters European HeadquartersPage Index Kofax Image Products VRS Getting Started Guide