Samsung 3.5" hard disk drives, spinpoint v40 manual At Command Register Descriptions

Page 61

DISK DRIVE OPERATION

6.4At Command Register Descriptions

Commands are issued to the drive by loading the pertinent registers in the command block with the needed parameters, and then writing the command code to the Command register. The manner in which a command is accepted varies. There are three classes of command acceptance (see Table 6-4), all based on the fact that to receive a command, BSY=0:

Upon receipt of a Class 1 command, the drive sets BSY within 400 nsec.

Upon receipt of a Class 2 command, the drive sets BSY within 400 nsec, sets up the sector buffer for a write operation, sets DRQ within 700 ∝ sec, and clears BSY within 400 nsec of setting DRQ.

Upon receipt of a Class 3 command, the drive sets BSY within 400 nsec, sets up the sector buffer for a write operation, sets DRQ within 20 msec, and clears BSY within 400 nsec of setting DRQ.

NOTE: DRQ may be set so quickly on Class 2 and Class 3 that the BSY transition is too short for BSY=1 to be recognized.

If a new command is issued to a drive which has an uncompleted command (subsequently referred to as Old_Command) in progress, the drive immediately responds to the new command (subsequently referred to as New_Command), even if execution of the Old_Command could have been completed.

SpinPoint V40 Product Manual

53

Image 61
Contents Spinpoint SpinPoint V40 Product Manual Table of Contents Irmware F Eatures Ervo S Ystem EAD and W Rite O PerationsSmart Protocol Overview Programming RequirementsTiming Service and Repair Maintenance Precautions107 General InformationTable of Figures Page Manual Organization User DefinitionScope Terminology and Conventions Commands and MessagesComputer Message Format C/SReference Introduction Key FeaturesDescription Hardware Requirements Standards and RegulationsSpecifications Specification SummaryLogical Configurations Physical SpecificationsPerformance Specifications 28.71 Power RequirementsSV6003H SV6014H SV8004H Environmental SpecificationsMtbf POH Reliability SpecificationsSpace Requirements InstallationMounting Unpacking InstructionsOrientation 2Mounting Dimensions in Millimeters 3Mounting-Screw Clearance ClearanceDC Power Connector Cable ConnectorsAT-Bus Interface Connector VentilationSpinPoint V40 Product Manual Jumper Block Configurations Options for Jumper Block Configuration 7DC Power Connector and AT-Bus Interface Cable Connections Drive InstallationParameter System Startup ProcedureSystem Setup Base Casting Assembly Head / Disk Assembly HDADC Spindle Motor Assembly Disk Drive OperationExploded Mechanical View Head Stack Assembly Disk Stack AssemblyVoice Coil Motor and Actuator Latch Assemblies Air Filtration SystemDrive Electronics Digital Signal Process and Interface ControllerAT Disk Controller 2SID2001 AT Controller Block Diagram Host Interface Control Block Disk Control Block Buffer Control BlockSpinPoint V40 Product Manual Read/Write IC Power ManagementDisk ECC Control Block Frequency SynthesizerAutomatic Gain Control Time Base GeneratorAsymmetry Correction Circuitry ASC Analog Anti-Aliasing Low Pass Filter3Read/Write 88C5200 Read and Write Operations Servo SystemRead Channel Write Channel Firmware FeaturesRead Caching Write Caching Automatic Defect Allocation Defect ManagementMulti-burst ECC Correction SmartBlank Signal Summary Signal ConventionsPhysical Interface Signal Descriptions Dmarq DMA Request DMACK- DMA AcknowledgeIntrq Drive Interrupt IOCS16- Drive 16-bit I/ORESET- Drive Reset PDIAG- Passed DiagnosticsIordy I/O Channel Ready SD4 SD8 SD6 SD9 SD5SD3 SD2Drive Host DriveDIR General Logical InterfaceBit Conventions EnvironmentSpinPoint V40 Product Manual 2 I/O Register Address Command Block RegistersControl Block Registers N N N A a aAlternate Status Register 3F6h Control Block Register DescriptionsDrive Address Register 3F7h Device Control Register 3F6hFeatures Register 1F1h Command Block Register DescriptionsError Register 1F1h Data Register 1F0hSector Count Register 1F2h Command Register 1F7hCylinder High Register 1F5h Cylinder Low Register 1F4hBSY Drdy DWF DSC DRQ Corr IDX ERR Status Register 1F7hAt Command Register Descriptions Command Parameter Used SpinPoint V40 Product Manual Execute Device Diagnostics 90h Check Power Mode 98h, E5hDownload Micro Code 92h Format Track 50h Flush Cache E7hIdentify Device ECh Xxxx Word Content DescriptionCapabilities Command set supported 95-128 0000h Reserved 129-159 Vendor specific 160-255 Idle Immediate 95h,E1h Idle 97h,E3hInitialize Device Parameters 91h Read Long 22hwith retry, 23h without retry Read Buffer E4hRead Multiple Command C4h Read Sectors 20hwith retry, 21hwithout retry Read Native Max Address F8hRecalibrate 1xh Read Verify Sectors 40hwith retry, 41hwithout retrySeek 7xh Mode Set Features EFhLBA InputsNormal outputs BSY Drdy DRQ ERRDescription Sleep 99h, E6h Set Multiple Mode C6hStandby 96h,E2h Smart disable operation D9hSmart B0h Smart enable operations D8h Smart enable/disable attribute autosave D2hSmart execute off-line immediate D4h Byte Descriptions Smart read data D0hOff-line data collection capability Value DefinitionSmart read log sector D5h Smart capabilitySmart return status DAh Smart save attribution value D3hStandby Immediate 94h, E0h Standby 96h, E2hWrite Buffer E8h Write DMA CAhWrite Sectors 30hwith retry, 31hwithout retry Write Multiple Command C5hSpinPoint V40 Product Manual Error Posting Reset ResponseProgramming Requirements BBK Command Error Register Status RegisterSleep mode Power ConditionsStandby mode Idle modeNormal mode Protocol Overview PIO Data in CommandsPIO Read Command PIO Data Out CommandsPIO Read Aborted Command PIO Write Aborted Command PIO Write CommandBSY=0 DRDY=1 BSY=1 BSY=0 DRQ=1 BSY=1 DRQ=0Non-Data Commands DMA Data Transfer Commands BSY=0 BSY=1 Aborted DMA Command Initialize DMA Reset DMA StatusBSY=1 BSY=0 Register transfers TimingDIOR-/DIOW Write PIO data transfers PIO timing parameters ModeAddr valid See note T1 t2 DIOR-/DIOW DIOR-/DIOW Multiword DMA data transferMultiword DMA timing parameters Mode Initiating an Ultra DMA data in burst Ultra DMA data transfer19Ultra DMA data burst timing requirements Ultra DMA data burst timing requirements5Sustained Ultra DMA data in burst Sustained Ultra DMA data in burst6Host pausing an Ultra DMA data in burst Host pausing an Ultra DMA data in burst7Device terminating an Ultra DMA data in burst 100 Device terminating an Ultra DMA data in burst8Host terminating an Ultra DMA data in burst Host terminating an Ultra DMA data in burst9Initiating an Ultra DMA data out burst 102 Initiating an Ultra DMA data out burst10Sustained Ultra DMA data out burst Sustained Ultra DMA data out burst11Device pausing an Ultra DMA data out burst 104 Device pausing an Ultra DMA data out burst12Host terminating an Ultra DMA data out burst Host terminating an Ultra DMA data out burst13Device terminating an Ultra DMA data out burst 106 Device terminating an Ultra DMA data out burstService And Repair Maintenance PrecautionsGeneral Information