60 of 66Part Lists - 3654 Portable H2/N2 Analyzer

Table 8-3:Analyzer Spare Parts

Part N°

Description

 

Flow chamber in PEEK, with spiral flow path for reduced flow demand for use

32013A

with TC sensors. Supplied with needle flow valve, outlet metal U-tube (6 mm

 

outside diameter), and 1 meter of inlet tubing.

 

 

32015.021/021

Flow chamber in PEEK with Swagelock fittings, for use with H2 radiation

resistant applications. With spiral flow path for reduced flow demand. Sup-

 

plied with EPDM O-rings. No tubing supplied. Suitable for use up to 10 bar.

 

 

32051

Adapter for attaching 32007F flow cell inlet tubing to customer's sample tube.

Includes one 6mm (32813) and one 8mm (32814) rubber sealing gasket.

 

 

 

32311

Flow meter equipped with metal exit tube. Graduation from 10 to 100%

 

 

32537.03

3 meter RS232 cable for use with portable instruments. Supplied with LEMO 6

connector instrument end and 9D connector computer end.

 

 

 

32688

WIN3654 Windows software and communications cable.

 

 

32751

Battery recharger with pack of two rechargeable NiCd batteries (Europe only).

 

 

32824A

Fill adapter kit for purge gas cylinder.

 

 

32939

Off-mode external power supply.

 

 

8.4 Sensor Spare Parts

The Orbisphere Recharge Kit should contain sufficient material for several years of sensor servicing. However, it must be replenished over time.

Table 8-4:Spare Parts Table

Part N°

Description

28114

Membrane support mounting tool.

 

 

28129

PPS sensor storage and calibration cap.

 

 

28614

Membrane holding ring removal tool, for 31XXX series sensors.

 

 

29142

Protection cap with O-ring seal for TC Sensors 31270, 31470, 31478 & 31570.

 

 

29228

Stainless steel membrane holding ring with extraction groove.

 

 

2935A

Halar membranes, 25 µm, box of 25.

 

 

2952A

Tefzel membranes, (32 mm diameter), 25 µm. Box of 25.

 

 

29561A

PFA membranes, (32 mm diameter), 25 µm. Box of 25.

 

 

 

Maintenance Kit for carbon dioxide, nitrogen, & hydrogen thermal conductivity

32746

sensors with protection cap 29142 for use with the 3654. Includes membranes

29561A, membrane holding ring 29228.01, O-rings 29039.0 and 28613.0, and

 

 

tools for sensor maintenance.

 

 

 

Maintenance Kit for hydrogen thermal conductivity sensors with protection cap

32747

29142 for use with the 3654. Includes membranes 2952A, membrane holding ring

 

29228.01, O-rings 29039.0 and 28613.0, and tools for sensor maintenance.

 

 

 

Maintenance Kit for hydrogen thermal conductivity sensors with protection cap

32748

29142 for use with the 3654. Includes membranes 2935A, membrane holding ring

 

29228.01, O-rings 29039.0 and 28613.0, and tools for sensor maintenance.

 

 

32920

Membrane mounting tool including centering guide and plunger.

 

 

ORBISPHERE

Operator Manual

Image 66
Contents Operator Manual Page Product Recycling Information Orbisphere Product Disposal Following only applies to European customersBoard Analog Board Spacer External Connector Restriction of Hazardous SubstancesTable of Contents Accessories and Attachments Maintenance and TroubleshootingCalibrations Specifications Part ListsAppendix a Glossary Table of Contents 3654 Portable H2/N2 Analyzer About this Manual Safety ConventionsManual Overview Revision HistorySafety Precautions Safety RecommendationsService and Repairs Precautionary Labels AcknowledgementsOrbisphere Installation What you have ReceivedWIN3654 PC Program Installation Sensor InstallationAtmospheric Pressure Equilibrium Connections External Power Supply optionalPurge Gas Connection Instrument PC ConnectionPin RS232 Signal Use Flow Chamber Installation Installation Completion Check List Flow Chamber Dissolved Gas MeasurementsOrbisphere Operating Instructions Operating ControlsMeasurement Phase on Select Gas Measurement Phase Measurement ModeTaking Measurements Storing Measurements In the Instrument Automatic Data AcquisitionManual Data Acquisition Storing and Accessing Measurements From a Computer Viewing Stored MeasurementsDownloading Stored Values Altering the Sampling Point Descriptions Copying ValuesSaving Values Printing Values Clearing Stored ValuesMonitoring Measurements In Real-Time Timebase Updating Rate Maximum Samples 10 divisionsAfter Use and Storage Options Setup Main Menu BasicsOptions Setup 3654 Portable H2/N2 Analyzer Gas Measurement Phase Reviewing Instrument ConfigurationConfiguring the Instrument Analyzer PC ConnectionMeasurement Units Automatic Data Acquisition Setting Sampling Intervals Membrane SelectionCalibration Medium Locking Out the Instrument’s CAL ButtonRolling Average Automatic Shutdown Orbisphere Calibrations Barometric Pressure Sensor CalibrationSensor Calibration Calibration Method Time Benefits Drawbacks ReferenceCalibration Setup Calibration In H2 or N2 at Atmospheric Pressure Calibration In H2 or N2 at Elevated Pressure Calibrating In a Liquid H2 or N2 Solution Accessories and Attachments Model 32311 Flow MeterModel 32939 External Power Supply Sensor Maintenance Maintenance and TroubleshootingPower Supply Maintenance ScheduleMembrane Replacement Mounting Dual MembranesRemoving the Membrane Installing the Membrane Orbisphere Place the membrane holding ring on the installation tool tip Purge Gas Cylinder Refill 1 N2 Purge Gas2 CO2 Purge Gas Filling the Purge Gas CylinderTroubleshooting Instrument Serial TestKeyboard Test Clock Settings Display TestAnalog Voltages View Measurements ViewProgram Identification Troubleshooting OperationDiagnostics Messages Continuous PurgeTroubleshooting Table Symptom Cause Possible SolutionSpecifications Instrument SpecificationsSensor Specifications Sensor Type 31 270 HSensor Type 31 272 H 31 570 N PFA Etfe EctfeSpecifications 3654 Portable H2/N2 Analyzer Part Lists Instrument ConfigurationsTC Sensor and Parts on Configured System Analyzer Spare PartsSensor Spare Parts Terms and Definitions Appendix a GlossaryCommon Units UnitGlossary 3654 Portable H2/N2 Analyzer Annex Tables and IllustrationsAnnex 3654 Portable H2/N2 Analyzer User Notes