Panasonic AJ-D250P How to release the menu protect mode, How to display the Diag menu

Page 26

Setup (Initial Settings)

5 Set the LOCAL/MENU/REMOTE switch to the LOCAL or REMOTE position. The unit is now set to the menu protect mode.

When the LOCAL/MENU/REMOTE switch is set to the MENU position, “MENU PROTECTED” appears on the video monitor screen instead of the menu setting mode being established.

<Note>

If, while the menu protect menu is set, the LOCAL/MENU/REMOTE switch is set to the menu position while the front panel’s COUNTER button is held down, the menu setting mode will be established, and regular menu settings can be performed.

Perform steps 2 through 7 in “How to perform the settings using the on-screen menus.”

(See page 23)

How to release the menu protect mode

1 Set the LOCAL/MENU/REMOTE switch to the MENU position while holding down the front panel’s COUNTER button.

The unit is now set to the menu setting mode, and the menu screen appears on the video monitor.

2 Perform steps 2 and 3 of “How to initiate the menu protect mode” described above.

The screen to confirm whether menu protect is to be initiated or canceled now appears on the video monitor.

MENU PROTECT OK?

NO

YES

3 Press the MENU-UP button or MENU-DOWN button to move the cursor to the NO position, and press the SET button.

The menu protect mode is now released.

How to display the DIAG menu

This unit incorporates a function for displaying the HOURS METER and software program version on the video monitor.

1 Set the LOCAL/MENU/REMOTE switch to the MENU position while holding down the EJECT button.

The unit is now set to the DIAG display mode, and the HOURS METER appears on the video monitor.

DIAG–MENU HOURS METER

H0

OPERATION

00000H

H1

DRUM RUN

00000H

H2

TAPE RUN

00000H

H3

THREADING

00000T

2 With the HOURS METER displayed, press the MENU-UP button or MENU-DOWN button while holding down the MODE button.

The software program version is displayed on the video monitor.

The front microcomputer version appears on the front panel’s counter display.

DIAG–MENU

VERSION

<NTSC>

 

 

 

IF

1.

-

- .

AV-SYSCON

1.

-

- .

SBC

1.

-

- .

CYLINDER

1.

-

- .

REEL

1.

-

- .

END

 

 

 

 

 

 

 

When the MENU-UP button or MENU-DOWN button is pressed again while holding down the MODE button, the HOURS METER display is restored.

3 Set the LOCAL/MENU/REMOTE switch to the LOCAL or REMOTE position.

The normal mode is now restored.

26

Image 26
Contents S0699W3119 a VQT8188-2FCC Note Contents Features IntroductionCounter display Parts and Their FunctionsFront panel ? Input Select switch Power switchLOCAL/MENU/REMOTE switch Cassette insertion slotRemote connector Headphones jackVolume control Reset buttonConnector panel REF Video in connector Signal GND terminalVideo in connector Audio in connectorsCassette Checkpoints for consumer-use DV tape playback TapesTape Description Operation Turning on the power/inserting a cassetteTurn on the unit’s power Insert the cassette tape Check that the Stop lamp is lightedStop mode Checkpoint for Still Timer settingPress the Stop button to end the recording RecordingPress the Play button while holding down the REC button Cue/review Pause/record frame-to-frame continuityPlayback Still picture playbackAudio switching Frame by frame advanceRepeat playback Setting the Begin and END points Menu modeSelect TC or CTL using the Counter button. Note Displaying the Begin and END points Setting the Begin and END points Front panelSetting the repeat playback mode User’s bit Time Codes and User’s BitTime codes TCR 00 07 04Now follow the same procedure as for setting the time code Setting the time codeSetting the user’s bit Down button Stop buttonPlaying back the time code/user’s bit 00 07 04Characters displayed Superimposed ScreensDisplay position Superimpose Screens How to restore the factory settings Setup Initial SettingsHow to perform the settings using the on-screen menus How to set the user default settings How to load the user default settings How to initiate the menu protect modeHow to release the menu protect mode How to display the Diag menuUnderlining denotes the factory mode setting Setup MenusSetting Description of setting Superimposed Display System menuBasic menu Operation menu Interface menu Tape Protect menu Time Code menu Video menu Audio menu Operation EditingPreparation Fading Audio editing functionsCutting Noise may appear here at the joins in the edit pointsFirst edit for insert editing First Edit Function Preparing the editing tapeFirst edit for assemble editing Communication parameters Interface specificationsRS-232C $ Data format External interface specificationsSending format computer VTR 3AHReceiving format VTR computer ExampleOAudio control commands Command list$ List of commands OCounter control commandsOMedia operation control commands ODisplay control commandsOEdit control commands OInput/output control commandsOOperation control commands OQuery control commands OCommunication control commands OSearches control commands OTimer control commandsParameters $ Audio control commands$ Counter control commands Sets the signal to be regenerated when the TCG time code TC data reference $ Display control commandsCTL data reference Menu item Setting Setting command $ Edit control commandsOWhen the CTL data is to be Used as the referenceM1 HEX display M2 HEX display $ Media operation control commands$ Input/output control commands STX ORC ETX $ Operation control commandsSTX OBF ETX STX OSF ETX Case of a Dvcpro format tapeCase of a DV format tape Parameters OIn the case of a Dvcpro Format tapeSTX OSR ETX TC mode, UB mode, Remain mode $ Query control commandsCTL mode OIn the case of CTL dataFf = Frames Rewind Eject Auto Back OFF STX QHC ETXRewind Play Play Pause STX QHR ETX OWith no parameter Switching dataParameter M1 HEX display M2 HEX display Bits supported AD9ADAADBADCADDADEADF OSP StopAD AD AD AD AD AddressfOBitmap table a Cassette RF Video Tape HardACK OFF STX QRS ETX Repeat ONE Time Continue OFF STX QSY ETXOBitmap table B Video Option STX QVM ETX OWhen CTL data is to be used asReference OParameter setting no completion command $ Communication control commandsOParameter setting normal $ Search control commands OWhen CTL data is to be usedOWhen the parameter value for Which the TC data serves as OWhen the counter value is toOWhen the parameter value for Be stored in the memoryOWhen the designated position is not to be entered Searches the counter value at the time when the command Data = wghmmssff Still mode is established upon completion $ Timer control commands $ Mode transition table Play REC PauseAudio Insert PauseCheckpoints for RS-232C communication $ Send commands and data returned from$ Send command intervals Error Messages Error No DescriptionProcedure for removing the tape manually in an emergency Emergency EjectCondensation Video Head CleaningMaintenance $ Output connectors Specifications$ Input connectors $ Digital video$ Digital audio Page Southeast Region Executive OfficeMid-Atlantic/New England Central Region