RS-232C
$Search control commands
Sends data of computer | Return data from VTR | Description of command | ||
|
|
| ||
|
|
| ||
[STX] SMP:data [ETX] | [STX] SMP [ETX] | Sets the repeat position. | ||
Parameters |
|
| When the BEGIN point and END point have been | |
data = pww:ghmmssff |
| designated in different modes, they are converted inside the | ||
OWhen the counter value is to |
| VTR and set in the mode which was last designated. | ||
be stored in the memory |
| Parameter “ff” is processed as “00” inside the VTR. | ||
p = | B: | BEGIN point |
| <Note> |
| E: | END point |
| This command is ignored while a search control command |
ww = | LC: CTL data reference |
| is being processed. | |
| SC:TC data reference |
|
| |
“ghmmssff” is omitted. |
|
|
OWhen the parameter value for which the CTL data serves as the reference is to be stored in the memory
p = B: BEGIN point
E:END point
ww = LP: CTL data reference
g = Blank: With a positive value
–sign: With a negative value
h = | 0 | 9: | Hours |
mm = 00 | 59: | Minutes | |
ss = | 00 | 59: | Seconds |
ff = | 00 | 29: | Frames |
OWhen the parameter value for which the TC data serves as the reference is to be stored in the memory
p = B: BEGIN point
E:END point
ww = SP: TC data reference
gh = 00 23: Hours
mm = 00 59: Minutes
ss = | 00 | 59: | Seconds |
ff = | 00 | 29: | Frames |
OWhen the designated position is not to be entered
data =
BN: No entry of BEGIN point
EN: No entry of END point
67