Panasonic AJ-D250P operating instructions Error Messages, Error No Description

Page 74

Error Messages

When a problem has occurred in the unit, one of the following error messages will appear on the tape counter.

Error No.

 

Description

 

 

 

— d —

 

Condensation (dew) has formed.

 

 

 

 

 

Appears when the servo fails to lock for 3 or more

 

 

seconds.

E — 00

 

When T&S&R is selected as the setup menu item

 

No.001 setting, “SERVO NOT LOCKED” is

 

 

 

 

displayed on the third line (line where the remaining

 

 

tape amount is indicated) of the monitor screen.

 

 

 

 

 

Appears when there is no head output for one or

 

 

more seconds (due to clogging, etc.).

 

 

“L” is displayed on the first line (counter line) of the

E — 01

 

monitor screen.

 

When T&S&R is selected as the setup menu item

 

 

 

 

No.001 setting, “LOW RF” is displayed on the third

 

 

line (line where the remaining tape amount is

 

 

indicated) of the monitor screen.

 

 

 

 

 

Appears when a blank area on the tape has been

 

 

detected.

 

 

“N” is displayed on the first line (counter line) of the

 

 

monitor screen.

 

 

When T&S&R is selected as the setup menu item

 

 

No.001 setting, “NO RF” is displayed on the third

E — 09

 

line (line where the remaining tape amount is

 

 

indicated) of the monitor screen.

 

 

When all the following conditions are met, the part of

 

 

the tape is recognized as a blank.

 

 

ONo output from any of the heads

 

 

OPlayback data cannot be read

 

 

ONo CTL signal

 

 

 

E — 11

 

The reel base which operates in line with the size of

 

the tape has been locked for 2.5 or more seconds.

 

 

 

 

 

 

 

Four or more 4 seconds have elapsed after the

 

 

cassette was inserted but the cassette is not

E — 21

 

lowered down inside the unit.

 

Alternatively, 4 or more seconds have elapsed after

 

 

 

 

the eject operation was initiated but the cassette is

 

 

not ejected.

 

 

 

E — 31

 

The loading operation is not completed within 4

 

seconds.

 

 

 

 

 

E — 32

 

The unloading operation is not completed within 4

 

seconds.

 

 

 

 

 

E — 41

 

The FG signal (rotational speed signal) is not output

 

from the cylinder motor.

 

 

 

 

 

E — 42

 

The PG signal (phase signal) is not output from the

 

cylinder motor.

 

 

 

 

 

E — 43

 

The cylinder motor speed is abnormally high.

 

 

 

E — 44

 

The cylinder motor speed is abnormally low.

 

 

 

Error No.

Description

 

 

E — 51

The FG signal (rotational speed signal) is not output

from the capstan motor.

 

 

 

E — 52

The capstan motor speed is abnormally high.

 

 

E — 53

The capstan motor speed is abnormally low.

 

 

E — 61

The supply (S) reel motor is locked.

 

 

E — 62

The take-up (T) reel motor is locked.

 

 

E — 63

The supply reel motor speed is abnormally high.

 

 

E — 64

The take-up reel motor speed is abnormally low.

 

 

E — 65

Abnormal tension has been detected.

 

 

 

The start or end processing operation fails to be

E — 66

completed even after 7 or more seconds have

 

elapsed.

 

 

E — 67

A communication error between SERVO and

AVSYS. Errors in the data.

 

 

 

E — 68

A communication error between SERVO and

AVSYS. The data is fixed at high or low.

 

 

 

E — 69

A problem in communication between SERVO and

AVSYS when the power was switched on.

 

 

 

 

This appears when there is a communication error

E — 6B

between IF and AVSYS. There is a problem with the

 

internal reference or external reference.

 

 

 

The fan motor has stopped.

 

“S” is displayed on the first line (counter line) of the

 

monitor screen.

 

When T&S&R is selected as the setup menu item

E — 70

No.001 setting, “FAN STOP” is displayed on the

 

third line (line where the remaining tape amount is

 

indicated) of the monitor screen.

 

When about an hour elapses, the unit is shut down

 

automatically.

 

 

E — 72

There is a problem in the solenoid drive circuit.

 

 

E — 73

There is a problem in the cleaning solenoid drive

circuit.

 

 

 

74

Image 74
Contents S0699W3119 a VQT8188-2FCC Note Contents Features IntroductionCounter display Parts and Their FunctionsFront panel ? Input Select switch Power switchLOCAL/MENU/REMOTE switch Cassette insertion slotRemote connector Headphones jackVolume control Reset buttonConnector panel REF Video in connector Signal GND terminalVideo in connector Audio in connectorsCassette Checkpoints for consumer-use DV tape playback TapesTape Description Operation Turning on the power/inserting a cassetteTurn on the unit’s power Insert the cassette tape Check that the Stop lamp is lightedStop mode Checkpoint for Still Timer settingPress the Stop button to end the recording RecordingPress the Play button while holding down the REC button Cue/review Pause/record frame-to-frame continuityPlayback Still picture playbackAudio switching Frame by frame advanceRepeat playback Setting the Begin and END points Menu modeSelect TC or CTL using the Counter button. Note Displaying the Begin and END points Setting the Begin and END points Front panelSetting the repeat playback mode User’s bit Time Codes and User’s BitTime codes TCR 00 07 04Now follow the same procedure as for setting the time code Setting the time codeSetting the user’s bit Down button Stop buttonPlaying back the time code/user’s bit 00 07 04Characters displayed Superimposed ScreensDisplay position Superimpose Screens How to restore the factory settings Setup Initial SettingsHow to perform the settings using the on-screen menus How to set the user default settings How to load the user default settings How to initiate the menu protect modeHow to release the menu protect mode How to display the Diag menuUnderlining denotes the factory mode setting Setup MenusSetting Description of setting Superimposed Display System menuBasic menu Operation menu Interface menu Tape Protect menu Time Code menu Video menu Audio menu Operation EditingPreparation Fading Audio editing functionsCutting Noise may appear here at the joins in the edit pointsFirst edit for insert editing First Edit Function Preparing the editing tapeFirst edit for assemble editing Communication parameters Interface specificationsRS-232C $ Data format External interface specificationsSending format computer VTR 3AHReceiving format VTR computer ExampleOAudio control commands Command list$ List of commands OCounter control commandsOMedia operation control commands ODisplay control commandsOEdit control commands OInput/output control commandsOOperation control commands OQuery control commands OCommunication control commands OSearches control commands OTimer control commandsParameters $ Audio control commands$ Counter control commands Sets the signal to be regenerated when the TCG time code TC data reference $ Display control commandsCTL data reference Menu item Setting Setting command $ Edit control commandsOWhen the CTL data is to be Used as the referenceM1 HEX display M2 HEX display $ Media operation control commands$ Input/output control commands STX ORC ETX $ Operation control commandsSTX OBF ETX STX OSF ETX Case of a Dvcpro format tapeCase of a DV format tape Parameters OIn the case of a Dvcpro Format tapeSTX OSR ETX TC mode, UB mode, Remain mode $ Query control commandsCTL mode OIn the case of CTL dataFf = Frames Rewind Eject Auto Back OFF STX QHC ETXRewind Play Play Pause STX QHR ETX OWith no parameter Switching dataParameter M1 HEX display M2 HEX display Bits supported AD9ADAADBADCADDADEADF OSP StopAD AD AD AD AD AddressfOBitmap table a Cassette RF Video Tape HardACK OFF STX QRS ETX Repeat ONE Time Continue OFF STX QSY ETXOBitmap table B Video Option STX QVM ETX OWhen CTL data is to be used asReference OParameter setting no completion command $ Communication control commandsOParameter setting normal $ Search control commands OWhen CTL data is to be usedOWhen the parameter value for Which the TC data serves as OWhen the counter value is toOWhen the parameter value for Be stored in the memoryOWhen the designated position is not to be entered Searches the counter value at the time when the command Data = wghmmssff Still mode is established upon completion $ Timer control commands $ Mode transition table Play REC PauseAudio Insert PauseCheckpoints for RS-232C communication $ Send commands and data returned from$ Send command intervals Error Messages Error No DescriptionProcedure for removing the tape manually in an emergency Emergency EjectCondensation Video Head CleaningMaintenance $ Output connectors Specifications$ Input connectors $ Digital video$ Digital audio Page Southeast Region Executive OfficeMid-Atlantic/New England Central Region