RS-232C
$Counter control commands
Sends data of computer | Return data from VTR |
| Description of command | ||
|
|
|
| ||
|
|
|
| ||
| [STX] CLP:data [ETX] | [STX] CLP [ETX] | Presets the designated counter value on the CTL counter. | ||
Parameters |
| The value will be corrected as follows if the | |||
data = ghmmssff |
| preset value has been set while the drop frame mode is | |||
g = Blank: With a positive value |
| established. |
| ||
– sign: With a negative value |
| 00:01:00:00 | 00:00:59:28 | ||
h = | 0 | 9: Hours |
| 00:01:00:01 | 00:00:59:29 |
mm = 00 | 59: Minutes |
| <Note> |
| |
ss = | 00 | 59: Seconds |
| This command is ignored while a search control command | |
ff = | 00 | 29: Frames |
| is being processed or while the tape is being ejected. | |
|
|
|
| ||
| [STX] CRN:m [ETX] | [STX] CRN [ETX] | Sets the signal to be regenerated when the TCG (time code | ||
Parameters |
| generator) is set to the regeneration mode. | |||
m = 0: TC & UB |
| <Note> |
| ||
1: TC |
|
| This command is ignored while a search control command | ||
2: UB |
|
| is being processed. | ||
|
|
|
| ||
| [STX] CRR [ETX] | [STX] CRR [ETX] | Uses the TCG in the REC RUN mode. The TCG counts up | ||
|
|
|
| during recording. The default value can be set using the | |
|
|
|
| CTS command. |
|
|
|
|
| <Note> |
|
|
|
|
| This command is ignored while a search control command | |
|
|
|
| is being processed, during recording and in the INSERT | |
|
|
|
| mode. |
|
|
|
|
| ||
| [STX] CRT [ETX] | [STX] CRT [ETX] | Resets the CTL counter data. | ||
|
|
|
| <Note> |
|
|
|
|
| This command is ignored while a search control command | |
|
|
|
| is being processed. | |
|
|
|
| ||
| [STX] CTC [ETX] | [STX] CTC [ETX] | Uses the reference data for searching and for the display | ||
|
|
|
| mode of the counter display as the time code data. | |
|
|
|
| <Note> |
|
|
|
|
| This command is ignored while a search control command | |
|
|
|
| is being processed. | |
|
|
|
| ||
| [STX] CTF [ETX] | [STX] CTF [ETX] | Uses the TCG in the FREE RUN mode. | ||
|
|
|
| The TCG continues to count up at all times regardless of | |
|
|
|
| the mode. The default value can be set using the CTS | |
|
|
|
| command. |
|
|
|
|
| The TCG starts counting up upon completion of the settings | |
|
|
|
| and when the VTR’s power is turned back on. | |
|
|
|
| <Note> |
|
|
|
|
| This command is ignored while a search control command | |
|
|
|
| is being processed, during recording and in the INSERT | |
|
|
|
| mode. |
|
|
|
|
| ||
| [STX] CTL [ETX] | [STX] CTL [ETX] | Uses the reference data for searching and for the display | ||
|
|
|
| mode of the counter display as the CTL data. | |
|
|
|
| <Note> |
|
|
|
|
| This command is ignored while a search control command | |
|
|
|
| is being processed. | |
|
|
|
| ||
| [STX] CTM:m [ETX] | [STX] CTM [ETX] | Sets the mode used by the TCG. | ||
Parameters |
| <Note> |
| ||
m = 0: REC RUN mode |
| This command is ignored while a search control command | |||
1: FREE RUN mode |
| is being processed, during recording and in the INSERT | |||
2: Regeneration mode |
| mode. |
| ||
3: External VITC mode |
|
|
| ||
|
|
|
|
|
|
48