Compur 4120 operation manual Accessories and spare parts, Art. Nr, Art.Nr

Page 32

Compur Statox 4120

11. Accessories and spare parts

Art. Nr.

STATOX 4120 ACCESSORIES

508885

STATOX Diagnostic box

518876

STATOX Diagnostic box charger 115 V

518850

STATOX Diagnostic box charger 230 V

509115

STATOX Control module service adapter

508588

STATOX Sensor head flow adapter

500223

STATOX Head Splash guard plug

500224

STATOX Head Calibration gas adapter plug

500225

STATOX Head plug adapter

508638

STATOX Sensor head rain shield

508539

STATOX Sensor head splash guard stainless

507283

STATOX Sensor head Splash guard PTFE

551869

STATOX Analog output inhibitor (for EPROM 02)

551703

STATOX Maintenance request (for EPROM ≥ 03)

561165

STATOX Upgrade COCl2 0,1 ppm

Art.Nr.

STATOX 4120 SPARE PARTS

508950

STATOX Diagnostic box battery

 

508778

STATOX Diagnostic box Lpcb inkl.LED

508836

STATOX Diagnostic box opto- coupler

509000

STATOX Diagnostic box mould

 

508415

STATOX Diagnostic box EPROM “02”

553030

STATOX Control module EPROM "02"

551711

STATOX Control module EPROM "03"

508410

STATOX Control module EPROM "03a"

561207

STATOX Control module EPROM "04"

505550

STATOX Control module front plate incl.LED

505543

STATOX Control module pcb

 

821155

STATOX Control module quartz 1,0 MHZ

508075

STATOX Control module scale

3 PPM

508083

STATOX Control module scale

5 PPM

508067

STATOX Control module scale 10 PPM

507994

STATOX Control module scale 15 PPM

508000

STATOX Control module scale 30 PPM

508018

STATOX Control module scale 50 PPM

507978

STATOX Control module scale 0,3 PPM

508042

STATOX Control module scale 0,5 PPM

507986

STATOX Control module scale 1,5 PPM

508059

STATOX Control module scale 100 PPM

508091

STATOX Control module scale 150 PPM

561215

STATOX Control module scale 0,1 PPM

507820

STATOX Control module T1 power supply

507804

STATOX Control module T2 transducer

505931

STATOX Control module alarm relay

534295

STATOX Manual -D-

 

32

Image 32
Contents Compur Statox Compur Statox Installation and electrical connections Trouble shootingMaintenance and calibration Compur Statox 4120 operationImportant notice Statox 4120 system Purpose of use and descriptionStatox 4120 sensor head Areas Statox 4120 rackOperation principle Construction ConnectionsStatox 4120 control module Bargraph displayLED SR 7 „System ready LED SF 8 „System FailDiagnostic box Mounting Installation and electrical connectionsStatox 4120 sensor head Connecting the signal cable Example of cable specifications Sensor head connection procedureInstallation instructions Statox 4120 rackStatox 4120 control module Toggle switch S3 Switch positions of the sensor head pcbSlide switch S1 Switch position for COCl2 Switch position for H2SSwitch position for HCN Switch position for HCl Switch position for ClO2 Switch position for Cl2Switch position for CO Alarm thresholds Detection modeCompur Statox 4120 operation Start upTrouble shooting SF flashingManually triggered self test of the system System failureUsing the diagnostic box Operation and error codes of the diagnostic boxDiagnostic box queries Button Display Diagnostic box error messagesCompur Statox Maintenance and calibration Inspection Statox 4120 Sensor headFilter cartridge replacement Generator cell replacementUsing span gas Sensor head calibrationUse ex works calibration ProcedureThis is the last opportunity to abort the procedure Maintenace request option Error C3 Too low sensitivity during self test Mounting the maintenance request pcbService mode control module Key Mode Relay PCS Relay WB Analog signal ReadingBridge Analog 20 mA 40-20mA Option analog output inhibition Analog Terminal Solder strapsSystem requirements Technical data General Gas Measuring range Sensor headRack Diagnostic boxControl module Art.Nr Accessories and spare partsArt. Nr Sensors & Generator Cells 558435