GE
0150-0193G
manual
DVMRe Triplex
Specs
Install
Alarms
Password
Return To Factory Defaults
Record Timer
On-screen Indicators
Ieee 1394 Firewire Port
Warranty
Configuration and Status
Page 1
DVMRe Triplex
Page 1
Page 2
Image 1
Page 1
Page 2
Contents
DVMRe Triplex
0150-0193G / April
Contents
RS232 Remote Control Protocol
Alarms
Searching
WebBrowser
10Macro Tables
11Warranty and Service
Features
Products Featured In This Manual
DVMRe Triplex Overview
Product Description
Default Passwords Four-Channel Units
Passwords
Package Contents
Installation Environment
Unpacking
Ten and Sixteen-Channel Units
Back Panel
Associated Equipment
Camera Inputs
Alarm I/O Port
Composite Monitor Output
Monitor Output
Alarm PCB
Alarm Input
Normally Open and Normally Closed Connections
External Alarm Acknowledge Input
Alarm Relay Output
AUX Port
Voltage 30V Max
RJ-45 Pin Configuration For RS485 Port
RS485 Connector
Ethernet Port
Ieee 1394 Firewire Port
RJ-45 Pin Configuration For Ethernet Port
Scsi Port
Gender on unit Female
DB-9 Pin Configuration For Port
Power-Up
RJ-45 Pin Configuration For RS232 Port
RS232 Port
Power-up procedure
Minimum Recommended Menu Setup
Check Video Input Quality
Check Record And Playback Quality
Principal Operating Modes
DMVRe Triplex Basic Operations
Front Panel
Play Forward Button Begins Playback
Live Viewing
Playback
Searching Recorded Data
Stop Playback
Stop Button
Sequence Button Number Button
Monitor Displays During Recording
Recording
Record Button
Display Options
Entering Active Cameo Mode
Active Cameos
Available Multiscreen Displays
Sequencing
Returning To The Default Sequence List
Selecting Cameras
Dwell Time
Changing Position And Color Of Title And Status Indicators
On-screen Indicators
Status Indicators
Sequencing In Cameos
Conditional Indicators
Triplex Mode
Status Display Box
ATM/POS Text Display
Reverse Play Button Jog / Shuttle Freeze Button Stop Button
Stop
Number Button Sequence Button
Print Image Feature
Zoom and Function Button
Equipment
Printer Setup
Conditions
Menu System Overview
Accessing The Menu System
Menu Notation In This Manual
Available Menus
Navigating The Menu System
Menus In This Manual
Menu Shortcuts
Opening the Drop Down Menus Rotate the Jog
Time/Date
Main Menu
Main Menu Overview
Main Menu → Time/Date → Time / Date Display
Main Menu → Time/Date → Set Date
Main Menu → Time/Date → Set Date Format
Main Menu → Time/Date → Set Master / Slave
Main Menu → Time/Date → Set Region
Main Menu → Time/Date → Network Time Setup
Main Menu → Sequencing → Multiscreen Dwell
Record
Main Menu → Sequencing → Fullscreen Dwell
Main Menu → Record → Event Settings
Main Menu → Record → Record Timer
Main Menu → Record → Record Quality
Record Quality Picture Quality Disk Space Needed
Camera 1 0.40 pps 2.5 spp
Main Menu → Record → Timelapse Record Rate
Main Menu → Record → Activity Record Rate
Main Menu → Record → Event Record Rate
Main Menu → Record → Alarm Record Rate
Main Menu → Record → Disk Maintenance
Main Menu → Record → Record Mode
Disk Test Setup Menu
No Overwrite
Main Menu → Record → Record Lock
Disable
Main Menu → Record → Auto Delete Mode
Alarms
Main Menu → Alarms → Input Configuration
Should not be the only alarm device on site
Main Menu → Alarms → Alarm Action
Main Menu → Alarms → Alarm Latch
Main Menu → Alarms → Enable / Disable
Main Menu → Alarms → Alarm Record Mode
Main Menu → Alarms → Alarm History
∙ Enable All ∙ Disable All
Main Menu → Alarms → Fullscreen Alarm
Main Menu → Alarms → Link To a Macro
Main Menu → Alarms → Relay Configuration
Main Menu → Alarms → Buzzer Setup
Main Menu → Alarms → Pre Alarm Duration
Main Menu → Alarms → Videoloss Action
Main Menu → Alarms → Notification
Email Notification Setup
Enable
TCP/IP Notification Setup
Macro
Main Menu → Alarms → Archive Alarms
Main Menu → Macro → Macro Record
Main Menu → Macro → Timed Macro Start
Macro Excluded Features
Main Menu → Macro → Edit Submacro
Motion Detection
Running a Macro
Daylight Savings Time Alternate Method
Individual Enable Menu
Main Menu → Motion Detection → Enable/Disable Detection
Main Menu → Motion Detection → Setup Parameters
Activity Detection Setup
Main Menu → Motion Detection → Setup Active Zones
Intrusion Detection Setup
Activity Grid Setup Screen
Main Menu → Camera Setup → Camera Titles
Camera Setup
Sensitivity Scope
Main Menu → Motion Detection → Indicate Detection
Titles Display
Main Menu → Camera Setup → AGC
Edit Titles
Camera Title Edit Menu
Individual Disable
Main Menu → Camera Setup → Camera Disable
Power Up Disable
Auto Disable Now
Main Menu → Camera Setup → MonB Svhs
Main Menu → Camera Setup → Camera Scope
Luminance Histogram
Audio Setup
Archive Setup
Communications
Pots Setup
Main Menu → Communications → RS232
Port
Main Menu → Communications → RS485
Baud Rate
Main Menu → Communications → Ethernet Settings
Return To Factory Defaults
Factory Settings
Front Panel Lock
Change Language
Ethernet Password
Changing the Installer or Operator Passwords
Activate The Ethernet Password
Deactivate The Ethernet Password
QuickInstall Menu Overview
QuickInstall Menu
QuickInstall Menu Item Primary Menu Location Section Manual
Operator Menu
SystemView Menu Overview
SystemView Menu
Operator Menu Item Primary Menu Location Section Manual
View Screen
View Screens
Record Rate
Record Timer
∙ Event Associated Cameras Up to
∙ On/Off On or Off
∙ Keyboard Lock On or Off ∙ Record Lock On or Off
∙ Network Address
∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off
∙ Http Port 80
Alarm Input
Alarms
Alarm Output
Alarm Acknowledge
Monitor-B Display During Alarm
Alarm Operations During Playback
Live Alarms Displays
Channel Units
Searching For Recorded Alarms
Alarm History Box
Recorded Alarms
Search Menu Overview
Searching
Quick Archive to CD
Disk Analysis Screen
Search Button
Function Button
Motion Search
Selecting Search Parameters
Search Filters
Text File Format
Retail Search
Uploading/Downloading the retailsearch .txt File
Date MM/DD/YY Time Hhmm
Local Retail Search Screen
Restrictions and Limitations
Search Results
Activate Search
Activity, Text, Motion, Alarm Search Results
WebBrowser
To access the web interface
Main Viewing Area
WaveBrowser Overview and Controls
∙ The Main Viewing Area The large blue area
Button Panel
Drop Down Volume List Box
Functionality
DVMRe Triplex WaveLink
Name Code Description Example
Email Links
General
Technical Specifications
Connections
Video
Motion Detection
Audio
Part Numbers
Message Type
Message Structure
Alarm Actions
Alarm/Event Fields
No Event Change 0000 0000b
Event Actions
Start Event 0000 0001b
Stop Event 0000 0010b
Data Structure
Front Panel Button Emulation
Description
Data structure
Configuration and Status
Macro Functions Table
Macro Tables
Macro Description Number
Event Day Time Macro to Run
Scheduled Macro Table
Factory Service
Warranty and Service
Factory Address
Advance Replacement Policy
Warranty and Return Information
0150-0193G
Related pages
Troubleshooting for Water Boss 900
Specifications for HP 6360t Mobile
LED Error Codes Aquastat EnviraCOM for Honeywell L7224A,C
Diagram #1 for JVC AV-30W475
When the slide show is over, press Button for Canon S50
Installed Memory XXX MB for Asus MES-VM
INSTRUCTIONS-PARTS LIST for Graco Inc 308584
Cable BOX Code List for Jasco RM24940
How does the state transition work in I/Q mapping?
More Information
Top
Page
Image
Contents