GE 0150-0193G manual Alarms, Alarm Input, Alarm Output, Alarm Acknowledge

Page 67

4Alarms

4.1 Alarm Input

Alarm devices are connected via the Alarm PCB on the back panel of the unit (see section 1.7). Each Alarm Input corresponds with the Camera Input of the same number. Alarm input to camera number assignments can be changed on 10 and 16-channel models. See Alarm Action menu (section 3.11).

4.2 Alarm Output

Front Panel Alarm LED: The LED located to the left and above the Alarm button is lit for the duration of the alarm.

Internal Buzzer: The internal buzzer is activated until it is Silenced and Acknowledged. This feature can be turned off in the menu system (see Buzzer Setup in section 3.11).

Monitor Displays: Discussed below in the On-screen Displays During Alarms section.

Output Relays: The alarm output relays are active for the duration of the alarm. This feature is configured in the menu system (see Alarm Action and Relay Configuration in section 3.11) and can be deactivated.

Macro Activation: Unit can be configured in the menu system to activate a macro when an alarm is detected.

Preset PTZ Camera commands: Unit can be configured in the menu system to send preset commands to specific cameras when an alarm is detected.

Record Rate: Record Rate can be increased by recording at the Alarm Record Rate (see section 3.10) and by Interleaved or Exclusive Recording (see Alarm Record mode in section 3.11).

4.3 Alarm Acknowledge

Pressing the Alarm button acknowledges to the unit that the alarm has been recognized and silences the internal buzzer. This does not clear the alarm condition.

4.4 On-screen Displays During Alarms

10 and 16-Channel Units

Monitor-A in Live Multiscreen Mode

Single Alarm: When a single alarm is received, the unit changes to 4-way display containing the camera in alarm, and three associated cameras. The three associated cameras are defined as a group in the menu system (see Alarm Action in section 3.11). The top left cameo displays the camera in alarm.

Second Alarm: When a second alarm is received, the unit changes to a 10-way multiscreen, displaying the alarm cameras in the top two cameos. The associated cameras are displayed in the remaining cameos.

Third Alarm: When a third alarm is received, the unit changes to a 9-way multiscreen, displaying the alarm cameras in the top three cameos. The associated cameras are displayed in the remaining cameos.

More than three alarms simultaneously: The unit switches to the maximum multiscreen display, i.e. 16 or 10-way.

4-Way

Single Alarm

10-Way

Second Alarm

9-Way

Third Alarm

0150-0193G

67

DVMRe Triplex

Image 67
Contents DVMRe Triplex 0150-0193G / April Contents WebBrowser AlarmsRS232 Remote Control Protocol Searching10Macro Tables 11Warranty and ServiceProduct Description Products Featured In This ManualFeatures DVMRe Triplex OverviewDefault Passwords Four-Channel Units PasswordsTen and Sixteen-Channel Units Installation EnvironmentPackage Contents UnpackingBack Panel Associated EquipmentMonitor Output Alarm I/O PortCamera Inputs Composite Monitor OutputAlarm PCB Alarm InputNormally Open and Normally Closed Connections Voltage 30V Max Alarm Relay OutputExternal Alarm Acknowledge Input AUX PortRJ-45 Pin Configuration For RS485 Port RS485 ConnectorEthernet Port Gender on unit Female RJ-45 Pin Configuration For Ethernet PortIeee 1394 Firewire Port Scsi PortRS232 Port Power-UpDB-9 Pin Configuration For Port RJ-45 Pin Configuration For RS232 PortCheck Record And Playback Quality Minimum Recommended Menu SetupPower-up procedure Check Video Input QualityPlay Forward Button Begins Playback DMVRe Triplex Basic OperationsPrincipal Operating Modes Front PanelLive Viewing Playback Sequence Button Number Button Stop PlaybackSearching Recorded Data Stop ButtonMonitor Displays During Recording RecordingRecord Button Available Multiscreen Displays Entering Active Cameo ModeDisplay Options Active CameosDwell Time Returning To The Default Sequence ListSequencing Selecting CamerasSequencing In Cameos On-screen IndicatorsChanging Position And Color Of Title And Status Indicators Status IndicatorsATM/POS Text Display Triplex ModeConditional Indicators Status Display BoxReverse Play Button Jog / Shuttle Freeze Button Stop Button StopNumber Button Sequence Button Print Image FeatureZoom and Function Button Equipment Printer SetupConditions Available Menus Accessing The Menu SystemMenu System Overview Menu Notation In This ManualOpening the Drop Down Menus Rotate the Jog Menus In This ManualNavigating The Menu System Menu ShortcutsMain Menu → Time/Date → Time / Date Display Main MenuTime/Date Main Menu OverviewMain Menu → Time/Date → Set Date Main Menu → Time/Date → Set Date FormatMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Set Region Main Menu → Time/Date → Network Time SetupMain Menu → Sequencing → Multiscreen Dwell RecordMain Menu → Sequencing → Fullscreen Dwell Record Quality Picture Quality Disk Space Needed Main Menu → Record → Record TimerMain Menu → Record → Event Settings Main Menu → Record → Record QualityCamera 1 0.40 pps 2.5 spp Main Menu → Record → Timelapse Record RateMain Menu → Record → Activity Record Rate Main Menu → Record → Event Record RateMain Menu → Record → Alarm Record Rate No Overwrite Main Menu → Record → Record ModeMain Menu → Record → Disk Maintenance Disk Test Setup MenuMain Menu → Record → Record Lock DisableShould not be the only alarm device on site AlarmsMain Menu → Record → Auto Delete Mode Main Menu → Alarms → Input ConfigurationMain Menu → Alarms → Alarm Action Main Menu → Alarms → Alarm Latch∙ Enable All ∙ Disable All Main Menu → Alarms → Alarm Record ModeMain Menu → Alarms → Enable / Disable Main Menu → Alarms → Alarm HistoryMain Menu → Alarms → Buzzer Setup Main Menu → Alarms → Link To a MacroMain Menu → Alarms → Fullscreen Alarm Main Menu → Alarms → Relay ConfigurationEmail Notification Setup Main Menu → Alarms → Videoloss ActionMain Menu → Alarms → Pre Alarm Duration Main Menu → Alarms → NotificationEnable TCP/IP Notification SetupMacro Main Menu → Alarms → Archive AlarmsMain Menu → Macro → Macro Record Main Menu → Macro → Timed Macro Start Macro Excluded FeaturesDaylight Savings Time Alternate Method Motion DetectionMain Menu → Macro → Edit Submacro Running a MacroActivity Detection Setup Main Menu → Motion Detection → Enable/Disable DetectionIndividual Enable Menu Main Menu → Motion Detection → Setup ParametersMain Menu → Motion Detection → Setup Active Zones Intrusion Detection SetupActivity Grid Setup Screen Main Menu → Motion Detection → Indicate Detection Camera SetupMain Menu → Camera Setup → Camera Titles Sensitivity ScopeCamera Title Edit Menu Main Menu → Camera Setup → AGCTitles Display Edit TitlesAuto Disable Now Main Menu → Camera Setup → Camera DisableIndividual Disable Power Up DisableMain Menu → Camera Setup → MonB Svhs Main Menu → Camera Setup → Camera ScopeLuminance Histogram Audio Setup Archive SetupPort Pots SetupCommunications Main Menu → Communications → RS232Main Menu → Communications → RS485 Baud RateMain Menu → Communications → Ethernet Settings Change Language Factory SettingsReturn To Factory Defaults Front Panel LockDeactivate The Ethernet Password Changing the Installer or Operator PasswordsEthernet Password Activate The Ethernet PasswordOperator Menu QuickInstall MenuQuickInstall Menu Overview QuickInstall Menu Item Primary Menu Location Section ManualSystemView Menu Overview SystemView MenuOperator Menu Item Primary Menu Location Section Manual View Screen View Screens∙ On/Off On or Off Record TimerRecord Rate ∙ Event Associated Cameras Up to∙ Http Port 80 ∙ Network Address∙ Keyboard Lock On or Off ∙ Record Lock On or Off ∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or OffAlarm Acknowledge AlarmsAlarm Input Alarm OutputChannel Units Alarm Operations During PlaybackMonitor-B Display During Alarm Live Alarms DisplaysSearching For Recorded Alarms Alarm History BoxRecorded Alarms Search Menu Overview SearchingQuick Archive to CD Disk Analysis ScreenSearch Button Function Button Motion SearchSelecting Search Parameters Search FiltersText File Format Retail SearchUploading/Downloading the retailsearch .txt File Date MM/DD/YY Time Hhmm Local Retail Search ScreenRestrictions and Limitations Search ResultsActivate Search Activity, Text, Motion, Alarm Search Results WebBrowser To access the web interfaceMain Viewing Area WaveBrowser Overview and Controls∙ The Main Viewing Area The large blue area Button Panel Drop Down Volume List BoxFunctionality DVMRe Triplex WaveLinkName Code Description Example Email Links Video Technical SpecificationsGeneral ConnectionsMotion Detection AudioPart Numbers Message Type Message StructureAlarm Actions Alarm/Event FieldsStop Event 0000 0010b Event ActionsNo Event Change 0000 0000b Start Event 0000 0001bData Structure Front Panel Button EmulationDescription Data structure Configuration and StatusMacro Functions Table Macro TablesMacro Description Number Event Day Time Macro to Run Scheduled Macro TableFactory Service Warranty and ServiceFactory Address Advance Replacement Policy Warranty and Return Information0150-0193G