GE 0150-0193G manual Main Menu → Record → Alarm Record Rate

Page 38

versa. The maximum record rate for multiple cameras is 48pps (NTSC)(40pps PAL). The maximum record rate for a single camera is 30pps (NTSC)(25pps PAL).

The bottom right corner of the menu contains a record duration calculator. The top line indicates the estimated recording time of the cameras in Activity record mode only. The bottom line indicates the estimated recording time, taking into consideration the amount of time the unit will spend in Time-lapse, Activity, Event, and/or Alarm record mode.

 

 

Activity Record Rate

 

 

 

 

Camera

1

: 0.40

pps 2.5 spp

% Time: 4%

 

 

Estimate of the % of time each

 

 

Camera

2

: 0.29

pps 3.5 spp

 

 

 

camera will typically spend in

 

 

 

periods of activity. For example

Camera

3

: 0.34

pps 2.9

spp

 

 

 

if you expect to have about 20

 

 

 

total periods of activity each day,

 

 

 

 

 

 

 

 

 

Camera

4

: 0.57

pps 1.8

spp

 

 

 

each lasting 3 minutes on average,

 

 

:

 

 

 

 

 

 

then the % of the time will be 4%.

 

 

 

 

 

 

 

 

(1 hour/24 hours)

 

 

:

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

Camera 15

: 0.40

pps 2.5

spp

 

 

 

 

Camera 16

: 0.40

pps 2.5

spp

 

 

 

 

 

 

 

 

68 days 11 h (ACTIVITY)

 

 

 

[CANCEL]

[OK]

 

9 days 16 h (Total)

 

 

1.Rotate the Jog to navigate, and the Shuttle to change the values.

2.To save changes and exit the menu: Select [OK], and then press the Enter button.

3.To exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button.

qMain Menu Record Alarm Record Rate

During an alarm, the unit records at the alarm record rate. The bottom of the menu contains a record duration calculator. The top line indicates the estimated recording time of the cameras in Alarm record mode only. The bottom line indicates the estimated recording time, taking into consideration the amount of time the unit will spend in Time-lapse, Activity, Event, and/or Alarm record mode.

The configuration of the Alarm Record Rate is closely associated with the Alarm Record Mode. For detailed information about configuring the Alarm Record Mode, see Alarm Record mode in section 3.11.

Global Alarm Record Rate

60 pps

40 days 20 h (Alarm)

15 days 11 h (Total)

[CANCEL] [OK]

Estimate of the % of time the unit will typically spend in alarm mode. For example

if you expect to have about 5 total periods of alarms each day, each lasting 3 minutes on average, then the % of the time will be 1%. (15 min/24 hours)

Record

Duration

Calculator

1.Rotate the Jog to navigate, and the Shuttle to change the values.

2.To save changes and exit the menu: Select [OK], and then press the Enter button.

3.To exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button.

0150-0193G

38

DVMRe Triplex

Image 38
Contents DVMRe Triplex 0150-0193G / April Contents Searching AlarmsRS232 Remote Control Protocol WebBrowser11Warranty and Service 10Macro TablesDVMRe Triplex Overview Products Featured In This ManualFeatures Product DescriptionPasswords Default Passwords Four-Channel UnitsUnpacking Installation EnvironmentPackage Contents Ten and Sixteen-Channel UnitsAssociated Equipment Back PanelComposite Monitor Output Alarm I/O PortCamera Inputs Monitor OutputNormally Open and Normally Closed Connections Alarm InputAlarm PCB AUX Port Alarm Relay OutputExternal Alarm Acknowledge Input Voltage 30V MaxEthernet Port RS485 ConnectorRJ-45 Pin Configuration For RS485 Port Scsi Port RJ-45 Pin Configuration For Ethernet PortIeee 1394 Firewire Port Gender on unit FemaleRJ-45 Pin Configuration For RS232 Port Power-UpDB-9 Pin Configuration For Port RS232 PortCheck Video Input Quality Minimum Recommended Menu SetupPower-up procedure Check Record And Playback QualityFront Panel DMVRe Triplex Basic OperationsPrincipal Operating Modes Play Forward Button Begins PlaybackLive Viewing Playback Stop Button Stop PlaybackSearching Recorded Data Sequence Button Number ButtonRecord Button RecordingMonitor Displays During Recording Active Cameos Entering Active Cameo ModeDisplay Options Available Multiscreen DisplaysSelecting Cameras Returning To The Default Sequence ListSequencing Dwell TimeStatus Indicators On-screen IndicatorsChanging Position And Color Of Title And Status Indicators Sequencing In CameosStatus Display Box Triplex ModeConditional Indicators ATM/POS Text DisplayStop Reverse Play Button Jog / Shuttle Freeze Button Stop ButtonZoom and Function Button Print Image FeatureNumber Button Sequence Button Conditions Printer SetupEquipment Menu Notation In This Manual Accessing The Menu SystemMenu System Overview Available MenusMenu Shortcuts Menus In This ManualNavigating The Menu System Opening the Drop Down Menus Rotate the JogMain Menu Overview Main MenuTime/Date Main Menu → Time/Date → Time / Date DisplayMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Set Date FormatMain Menu → Time/Date → Set Date Main Menu → Time/Date → Network Time Setup Main Menu → Time/Date → Set RegionMain Menu → Sequencing → Fullscreen Dwell RecordMain Menu → Sequencing → Multiscreen Dwell Main Menu → Record → Record Quality Main Menu → Record → Record TimerMain Menu → Record → Event Settings Record Quality Picture Quality Disk Space NeededMain Menu → Record → Timelapse Record Rate Camera 1 0.40 pps 2.5 sppMain Menu → Record → Event Record Rate Main Menu → Record → Activity Record RateMain Menu → Record → Alarm Record Rate Disk Test Setup Menu Main Menu → Record → Record ModeMain Menu → Record → Disk Maintenance No OverwriteDisable Main Menu → Record → Record LockMain Menu → Alarms → Input Configuration AlarmsMain Menu → Record → Auto Delete Mode Should not be the only alarm device on siteMain Menu → Alarms → Alarm Latch Main Menu → Alarms → Alarm ActionMain Menu → Alarms → Alarm History Main Menu → Alarms → Alarm Record ModeMain Menu → Alarms → Enable / Disable ∙ Enable All ∙ Disable AllMain Menu → Alarms → Relay Configuration Main Menu → Alarms → Link To a MacroMain Menu → Alarms → Fullscreen Alarm Main Menu → Alarms → Buzzer SetupMain Menu → Alarms → Notification Main Menu → Alarms → Videoloss ActionMain Menu → Alarms → Pre Alarm Duration Email Notification SetupTCP/IP Notification Setup EnableMain Menu → Macro → Macro Record Main Menu → Alarms → Archive AlarmsMacro Macro Excluded Features Main Menu → Macro → Timed Macro StartRunning a Macro Motion DetectionMain Menu → Macro → Edit Submacro Daylight Savings Time Alternate MethodMain Menu → Motion Detection → Setup Parameters Main Menu → Motion Detection → Enable/Disable DetectionIndividual Enable Menu Activity Detection SetupActivity Grid Setup Screen Intrusion Detection SetupMain Menu → Motion Detection → Setup Active Zones Sensitivity Scope Camera SetupMain Menu → Camera Setup → Camera Titles Main Menu → Motion Detection → Indicate DetectionEdit Titles Main Menu → Camera Setup → AGCTitles Display Camera Title Edit MenuPower Up Disable Main Menu → Camera Setup → Camera DisableIndividual Disable Auto Disable NowLuminance Histogram Main Menu → Camera Setup → Camera ScopeMain Menu → Camera Setup → MonB Svhs Archive Setup Audio SetupMain Menu → Communications → RS232 Pots SetupCommunications PortBaud Rate Main Menu → Communications → RS485Main Menu → Communications → Ethernet Settings Front Panel Lock Factory SettingsReturn To Factory Defaults Change LanguageActivate The Ethernet Password Changing the Installer or Operator PasswordsEthernet Password Deactivate The Ethernet PasswordQuickInstall Menu Item Primary Menu Location Section Manual QuickInstall MenuQuickInstall Menu Overview Operator MenuOperator Menu Item Primary Menu Location Section Manual SystemView MenuSystemView Menu Overview View Screens View Screen∙ Event Associated Cameras Up to Record TimerRecord Rate ∙ On/Off On or Off∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off ∙ Network Address∙ Keyboard Lock On or Off ∙ Record Lock On or Off ∙ Http Port 80Alarm Output AlarmsAlarm Input Alarm AcknowledgeLive Alarms Displays Alarm Operations During PlaybackMonitor-B Display During Alarm Channel UnitsRecorded Alarms Alarm History BoxSearching For Recorded Alarms Searching Search Menu OverviewSearch Button Disk Analysis ScreenQuick Archive to CD Motion Search Function ButtonSearch Filters Selecting Search ParametersUploading/Downloading the retailsearch .txt File Retail SearchText File Format Local Retail Search Screen Date MM/DD/YY Time HhmmActivate Search Search ResultsRestrictions and Limitations Activity, Text, Motion, Alarm Search Results To access the web interface WebBrowser∙ The Main Viewing Area The large blue area WaveBrowser Overview and ControlsMain Viewing Area Drop Down Volume List Box Button PanelName Code Description Example DVMRe Triplex WaveLinkFunctionality Email Links Connections Technical SpecificationsGeneral VideoPart Numbers AudioMotion Detection Message Structure Message TypeAlarm/Event Fields Alarm ActionsStart Event 0000 0001b Event ActionsNo Event Change 0000 0000b Stop Event 0000 0010bDescription Front Panel Button EmulationData Structure Configuration and Status Data structureMacro Description Number Macro TablesMacro Functions Table Scheduled Macro Table Event Day Time Macro to RunFactory Address Warranty and ServiceFactory Service Warranty and Return Information Advance Replacement Policy0150-0193G