Disk Test Setup

Disk Test:

DISABLE

Test Frequency in hours:

0

Test Duration:

Fast

[CANCEL]

[OK]

 

 

Disk Test Result:

Disk Failed

Disk 1: Write Error

 

Disk 2: Write Error

 

Use the Jog to move between the menu fields and the Shuttle for the selections within the fields. When satisfied with the selections select OK and press the Enter button to execute.

The Disk Test will run in the background and will not interfere with normal operations. Once the disk test is done, a message will appear on the screen indicating the test result.

Disk Test Result

 

Disk Test Result

 

 

Disk Failure

Disk Test Success

 

Disk 1:Write Error

 

 

Disk 2:Write Error

[OK]

 

[OK]

PASSED

FAILED

Press the Enter button to clear from the display.

Should a disk test fail, several actions will performed:

An icon will be displayed indicating disk failure. It is displayed on Monitor A on the bottom of the screen in the middle. This icon will only disappear when the disk is replaced.

If the alarm or record email option is enabled in the Email Notification Setup Screen, an email will be sent indicating that a disk failure occurred.

qMain Menu Record Record Lock

Use this menu to set the Record Lock feature. This feature disables the front panel record button. Setting Record Lock to ON will start the unit recording if it is not currently in the Record mode.

OFF

ON

0150-0193G

40

DVMRe Triplex

Image 40
Contents DVMRe Triplex 0150-0193G / April Contents Alarms RS232 Remote Control ProtocolSearching WebBrowser11Warranty and Service 10Macro TablesProducts Featured In This Manual FeaturesDVMRe Triplex Overview Product DescriptionPasswords Default Passwords Four-Channel UnitsInstallation Environment Package ContentsUnpacking Ten and Sixteen-Channel UnitsAssociated Equipment Back PanelAlarm I/O Port Camera InputsComposite Monitor Output Monitor OutputAlarm PCB Alarm InputNormally Open and Normally Closed Connections Alarm Relay Output External Alarm Acknowledge InputAUX Port Voltage 30V MaxRJ-45 Pin Configuration For RS485 Port RS485 ConnectorEthernet Port RJ-45 Pin Configuration For Ethernet Port Ieee 1394 Firewire PortScsi Port Gender on unit FemalePower-Up DB-9 Pin Configuration For PortRJ-45 Pin Configuration For RS232 Port RS232 PortMinimum Recommended Menu Setup Power-up procedureCheck Video Input Quality Check Record And Playback QualityDMVRe Triplex Basic Operations Principal Operating ModesFront Panel Play Forward Button Begins PlaybackLive Viewing Playback Stop Playback Searching Recorded DataStop Button Sequence Button Number ButtonMonitor Displays During Recording RecordingRecord Button Entering Active Cameo Mode Display OptionsActive Cameos Available Multiscreen DisplaysReturning To The Default Sequence List SequencingSelecting Cameras Dwell TimeOn-screen Indicators Changing Position And Color Of Title And Status IndicatorsStatus Indicators Sequencing In CameosTriplex Mode Conditional IndicatorsStatus Display Box ATM/POS Text DisplayStop Reverse Play Button Jog / Shuttle Freeze Button Stop ButtonNumber Button Sequence Button Print Image FeatureZoom and Function Button Equipment Printer SetupConditions Accessing The Menu System Menu System OverviewMenu Notation In This Manual Available MenusMenus In This Manual Navigating The Menu SystemMenu Shortcuts Opening the Drop Down Menus Rotate the JogMain Menu Time/DateMain Menu Overview Main Menu → Time/Date → Time / Date DisplayMain Menu → Time/Date → Set Date Main Menu → Time/Date → Set Date FormatMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Network Time Setup Main Menu → Time/Date → Set RegionMain Menu → Sequencing → Multiscreen Dwell RecordMain Menu → Sequencing → Fullscreen Dwell Main Menu → Record → Record Timer Main Menu → Record → Event SettingsMain Menu → Record → Record Quality Record Quality Picture Quality Disk Space NeededMain Menu → Record → Timelapse Record Rate Camera 1 0.40 pps 2.5 sppMain Menu → Record → Event Record Rate Main Menu → Record → Activity Record RateMain Menu → Record → Alarm Record Rate Main Menu → Record → Record Mode Main Menu → Record → Disk MaintenanceDisk Test Setup Menu No OverwriteDisable Main Menu → Record → Record LockAlarms Main Menu → Record → Auto Delete ModeMain Menu → Alarms → Input Configuration Should not be the only alarm device on siteMain Menu → Alarms → Alarm Latch Main Menu → Alarms → Alarm ActionMain Menu → Alarms → Alarm Record Mode Main Menu → Alarms → Enable / DisableMain Menu → Alarms → Alarm History ∙ Enable All ∙ Disable AllMain Menu → Alarms → Link To a Macro Main Menu → Alarms → Fullscreen AlarmMain Menu → Alarms → Relay Configuration Main Menu → Alarms → Buzzer SetupMain Menu → Alarms → Videoloss Action Main Menu → Alarms → Pre Alarm DurationMain Menu → Alarms → Notification Email Notification SetupTCP/IP Notification Setup EnableMacro Main Menu → Alarms → Archive AlarmsMain Menu → Macro → Macro Record Macro Excluded Features Main Menu → Macro → Timed Macro StartMotion Detection Main Menu → Macro → Edit SubmacroRunning a Macro Daylight Savings Time Alternate MethodMain Menu → Motion Detection → Enable/Disable Detection Individual Enable MenuMain Menu → Motion Detection → Setup Parameters Activity Detection SetupMain Menu → Motion Detection → Setup Active Zones Intrusion Detection SetupActivity Grid Setup Screen Camera Setup Main Menu → Camera Setup → Camera TitlesSensitivity Scope Main Menu → Motion Detection → Indicate DetectionMain Menu → Camera Setup → AGC Titles DisplayEdit Titles Camera Title Edit MenuMain Menu → Camera Setup → Camera Disable Individual DisablePower Up Disable Auto Disable NowMain Menu → Camera Setup → MonB Svhs Main Menu → Camera Setup → Camera ScopeLuminance Histogram Archive Setup Audio SetupPots Setup CommunicationsMain Menu → Communications → RS232 PortBaud Rate Main Menu → Communications → RS485Main Menu → Communications → Ethernet Settings Factory Settings Return To Factory DefaultsFront Panel Lock Change LanguageChanging the Installer or Operator Passwords Ethernet PasswordActivate The Ethernet Password Deactivate The Ethernet PasswordQuickInstall Menu QuickInstall Menu OverviewQuickInstall Menu Item Primary Menu Location Section Manual Operator MenuSystemView Menu Overview SystemView MenuOperator Menu Item Primary Menu Location Section Manual View Screens View ScreenRecord Timer Record Rate∙ Event Associated Cameras Up to ∙ On/Off On or Off∙ Network Address ∙ Keyboard Lock On or Off ∙ Record Lock On or Off∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off ∙ Http Port 80Alarms Alarm InputAlarm Output Alarm AcknowledgeAlarm Operations During Playback Monitor-B Display During AlarmLive Alarms Displays Channel UnitsSearching For Recorded Alarms Alarm History BoxRecorded Alarms Searching Search Menu OverviewQuick Archive to CD Disk Analysis ScreenSearch Button Motion Search Function ButtonSearch Filters Selecting Search ParametersText File Format Retail SearchUploading/Downloading the retailsearch .txt File Local Retail Search Screen Date MM/DD/YY Time HhmmRestrictions and Limitations Search ResultsActivate Search Activity, Text, Motion, Alarm Search Results To access the web interface WebBrowserMain Viewing Area WaveBrowser Overview and Controls∙ The Main Viewing Area The large blue area Drop Down Volume List Box Button PanelFunctionality DVMRe Triplex WaveLinkName Code Description Example Email Links Technical Specifications GeneralConnections VideoMotion Detection AudioPart Numbers Message Structure Message TypeAlarm/Event Fields Alarm ActionsEvent Actions No Event Change 0000 0000bStart Event 0000 0001b Stop Event 0000 0010bData Structure Front Panel Button EmulationDescription Configuration and Status Data structureMacro Functions Table Macro TablesMacro Description Number Scheduled Macro Table Event Day Time Macro to RunFactory Service Warranty and ServiceFactory Address Warranty and Return Information Advance Replacement Policy0150-0193G