View Screens 1 through 10: These menus provide an overview of the units current operating parameters and the menu settings selected by the user or installer. Each View Screen is described in the following tables. The default values are bolded and italicized.
The View Screens
View Screen 1
Alarm Input
∙Enable/Disable: 1 = Enabled, 0 = Disabled
∙Normally Open or Normally Closed: 0 = Open, C = Closed
∙Macro: Macro number if activated.
Alarm Action
∙Freeze: 1 = Freeze, 0 = No Freeze
∙Cameras: Primary camera in alarm and three associated cameras.
∙Relay: 1, 2, 1+2, or None.
∙Intrusion AND/OR: AND, OR
View Screen 2
Camera
∙Enable/Disable: 1 = Enabled, 0 = Disabled
∙Signal Gain: AGC setting from 1 through 100. 50
∙Covert Camera: Yes or No
∙Camera Title: Camera x, x=number
Videoloss Action
∙Relay 1: 1 = Enabled, 0 = Disabled
∙Relay 2: 1 = Enabled, 0 = Disabled
∙Buzzer: 1 = Enabled, 0 = Disabled
View Screen 3
Motion Detection
∙Enable/Disable: 1 = Enabled, 0 = Disabled
∙Activity or Intrusion Detection: I = Intrusion, A = Activity
∙Sensitivity: 1 through 10, 5
∙Relay Output: None, 1, 2, 1+2
∙Link to Event: Yes or No
∙Rejection Ratio: High, Medium, or Low
∙Target Size: 1 through 256
∙Alarm Camera: 1 through 4, 10 or 16
64 | DVMRe Triplex |