POST error messages

Table 17 provides information about the POST error messages that can appear during startup.

Note that these diagnostic error messages require the attachment of a monitor, keyboard, and mouse (before you power on the system) to enable you to see them.

In the following error messages, X can be any number or letter.

Table 17. POST error messages

Error

Meaning

FRU/action

code/Symptom

 

 

 

 

 

 

 

062

Three consecutive boot

1.

Run Configuration/Setup

 

failures using the default

 

2.

Battery

 

configuration

 

3.

System board

 

 

 

 

4.

Processor

 

 

 

101, 102

System and processor error

System board

 

 

 

106

System and processor error

System board

 

 

 

 

111

Channel check error

1.

Failing ISA Adapter

 

 

 

 

2.

DIMM

 

 

3.

System board

 

 

 

 

114

Adapter read-only memory

1.

Failing Adapter

 

error

 

2.

Run Diagnostics

 

 

 

 

 

 

129

Internal cache error

1.

Processor

 

 

 

 

2.

Optional processor (if installed)

 

 

 

 

151

Real-time clock error

1.

Run Diagnostics

 

 

 

 

2.

Battery

 

 

3.

System board

 

 

 

 

161

Real-time clock battery error

1.

Run Configuration/Setup

 

 

 

 

2.

Battery

 

 

3.

System board

 

 

 

 

162

Device Configuration error

1.

Run Configuration/Setup

 

 

 

 

 

Note: Be sure to load the default settings and any

 

 

 

additional desired settings; then, save the configuration.

 

 

2.

Battery

 

 

3.

Failing Device

 

 

4.

System board

 

 

 

 

163

Real-time clock error

1.

Run Configuration/Setup

 

 

 

 

2.

Battery

 

 

3.

System board

 

 

 

 

164

Memory configuration

1.

Run Configuration/Setup

 

changed

 

2.

DIMM

 

 

 

 

 

175

Hardware error

System board

 

 

 

 

92NAS 200 User’s Reference

Page 104
Image 104