Table 18. Diagnostic error messages (continued)

Error Code

Meaning

FRU/action

 

 

 

 

166-342-000

System Management failed:

1.

Ensure that the latest firmware levels for the Remote

 

Remote Supervisor Adapter

 

 

Supervisor Adapter and BIOS

 

BIST indicate failed tests).

 

 

2.

Disconnect all server and option power cords from the

 

 

 

 

 

unit, wait 30 seconds, reconnect, then retry.

 

 

3.

Remote Supervisor Adapter

 

 

 

 

166-400-000

System Management failed:

1.

Re-flash or update firmware for ISMP

 

System management

 

2.

System board

 

hardware on system board

 

 

 

 

failed) (ISMP Self Test Result

 

 

 

failed tests: x where x =

 

 

 

Flash, RAM, or ROM).

 

 

 

 

 

180-XXX-000

Diagnostics LED failure

Run the diagnostics LED test for the failing LED.

 

 

 

 

180-XXX-001

Failed front LED panel test

 

 

 

 

 

 

180-XXX-002

Failed diagnostics LED panel

1.

System board

 

test

2.

Power-switch assembly

 

 

 

 

 

 

180-XXX-005

Failed SCSI backplane LED

1.

SCSI backplane

 

test

 

2.

SCSI backplane cable

 

 

 

 

3.

System board

 

 

 

180-XXX-006

Memory Board LED test

Suspected part:

 

 

1.

Memory

 

 

2.

Processor/PCI board

 

 

3.

System board

 

 

 

 

180-361-003

Failed fan LED test

1.

Fans

 

 

 

 

2.

System board

 

 

 

 

201-XXX-0NN

Failed Memory test

1.

DIMM Location DIMM1 - DIMM4 where NN can be a

 

 

 

 

 

value from 01 to 04. 01 = DIMM2, 02 = DIMM1, 03 =

 

 

 

DIMM4, 04 = DIMM3

 

 

2.

System board

 

 

 

 

201-XXX-999

Multiple DIMM failure; see

1.

See error text for failing DIMMs

 

error text for failing DIMMs

 

2.

System board

 

 

 

 

 

 

202-XXX-001

Failed system cache test

1.

VRM 1

 

 

 

 

2.

Microprocessor 1

 

 

 

 

202-XXX-002

Failed system cache test

1.

VRM 2

 

 

 

 

2.

Microprocessor 2

 

 

 

 

206-XXX-000

Failed diskette drive test

1.

Cable

 

 

 

 

2.

Diskette drive

 

 

3.

System board

 

 

 

 

215-XXX-000

Failed IDE CD-ROM test

1.

CD-ROM drive cables

 

 

 

 

2.

CD-ROM drive

 

 

3.

System board

 

 

 

 

217-198-XXX

Could not establish drive

1.

Check cable and termination

 

parameter

 

2.

SCSI backplane

 

 

 

 

3.

Fixed disk

 

 

 

 

Appendix C. Engine POST messages 103