Note: Do not replace any controllers until you have followed the POST (ISPR) error procedures (see “POST (ISPR) error procedures” on page 71).). Replace a ServeRAID controller only when indicated to do so in the POST (ISPR) error procedures.

XXXin Table 12 is used as a placeholder and may be any letter or number in an actual error message.

Table 12. ServeRAID-4x problems and actions

Problem

Action

 

 

1XXX (Microcode Checksum Error)

ServeRAID-4 controller

 

 

 

2XXX thru 5XXX (Code DRAM Error)

1.

Install download jumpers, flash latest

 

 

level BIOS and firmware for controller.

 

 

Remove jumpers.

 

2.

ServeRAID-4 controller

 

 

 

6XXX (Cache DRAM Error) (ServeRAID-4H

1.

Reseat Daughter card

only)

2.

Install download jumpers, flash latest

 

 

level BIOS and firmware for controller.

 

 

Remove jumpers.

 

3.

ServeRAID-4 controller

 

 

 

7XXX thru 8XXX (Host/Local PCI Bus

1.

Install download jumpers, flash latest

Interface Error)

 

level BIOS and firmware for controller.

 

 

Remove jumpers.

 

2.

ServeRAID-4 controller

 

 

 

9ZXX thru BZXX SCSI Bus error caused by

1.

Follow indications in the POST error

cables, termination, defective drives, and so

 

procedures (see “POST (ISPR) error

on). The Z refers to the specific channel or

 

procedures” on page 71). Follow those

channels that cause the error.

 

instructions before continuing with the

 

 

next steps listed in this table.

 

2.

SCSI cable

 

3.

SCSI backplane

 

4.

Hard drive

 

5.

ServeRAID-4 controller

 

 

 

EFFE (Firmware code corrupt or download

1.

Flash latest level BIOS and firmware for

jumpers are in place)

 

controller. Remove jumpers.

 

2.

ServeRAID-4 controller

 

 

 

FFFF or other code not listed

1.

Follow indications in the POST (ISPR)

 

 

error procedures (“POST (ISPR) error

 

 

procedures” on page 71).

 

2.

SCSI cable

 

3.

SCSI backplane

 

4.

Hard drive

 

5.

ServeRAID-4 controller

 

 

 

Testing the ServeRAID 4x adapter

You can run all diagnostic operations for the ServeRAID adapters through the IBM ServeRAID Configuration software in the Advanced Functions option. You can run subsystem diagnostics through the system diagnostics.

Note: Before running any test, back up the current disk array configuration using the ServeRAID diagnostics test program. Always keep a current backup of the ServeRAID configuration information. Dynamic changes may occur in the configuration due to hot-spare replacement.

Chapter 7. Troubleshooting 73

Page 85
Image 85
IBM 201 manual Testing the ServeRAID 4x adapter, ServeRAID-4x problems and actions