Table 17. POST error messages (continued)

Error

Meaning

FRU/action

code/Symptom

 

 

 

 

 

 

 

604

Diskette-drive error

1.

Run Configuration/Setup and diagnostics

 

 

 

 

2.

Diskette Drive

 

 

3.

Drive cable

 

 

4.

System board

 

 

 

 

605

Unlock failure

1.

Diskette drive

 

 

 

 

2.

Drive cable

 

 

3.

System board

 

 

 

 

662

Diskette-drive configuration

1.

Run Configuration/Setup and Diagnostics

 

error

 

2.

Diskette Drive

 

 

 

 

3.

Drive Cable

 

 

4.

System board

 

 

 

 

762

Coprocessor configuration

1.

Run Configuration/Setup

 

error

 

2.

Battery

 

 

 

 

3.

Processor

 

 

 

 

962

Parallel-port error

1.

Disconnect external cable on parallel port.

 

 

 

 

2.

Run Configuration/Setup

 

 

3.

System board

 

 

 

 

11XX

System-board serial port 1 or

1.

Disconnect external cable on serial port.

 

2 error

2.

Run Configuration/Setup

 

 

 

 

3.

System board

 

 

 

 

0001200

Machine-check architecture

1.

Processor

 

error

 

2.

Optional Processor

 

 

 

 

 

 

0001295

ECC circuit check

1.

System board

 

 

 

 

2.

Processor

 

 

 

 

1301

I2C cable to front panel not

1.

Cable

 

found

 

2.

Front panel

 

 

 

 

3.

Power switch assembly

 

 

4.

System board

 

 

 

 

1302

I2C cable from system board

1.

Cable

 

to power on and reset

 

2.

Power Switch Assembly

 

switches not found

 

3.

System board

 

 

 

 

 

 

1303

I2C cable from system board

1.

Cable

 

to power backplane not

 

2.

Power backplane

 

found

 

3.

System board

 

 

 

 

 

 

1304

I2C cable to diagnostic LED

1.

Cable

 

board not found

 

2.

Diagnostic LED Board

 

 

 

 

3.

Power Switch Assembly

 

 

4.

System board

 

 

 

 

94NAS 200 User’s Reference