IBM 201 manual NAS 200 User’s Reference

Models: 201

1 140
Download 140 pages 39.72 Kb
Page 114
Image 114

Table 18. Diagnostic error messages (continued)

Error Code

Meaning

FRU/action

 

 

 

 

166-198-000

System Management

1. Re-run the Diagnostic Test

 

aborted: (Unable to

 

2. Fix other error conditions and retry. These include other

 

communicate with the

 

 

Failed System Management tests and items logged in the

 

Remote Supervisor Adapter.

 

 

 

optional Remote Supervisor Adapter’s System Error Log

 

It may be busy. Run the test

 

 

3.

Disconnect all server and option power cords from the

 

again). (Communication with

 

the Remote Supervisor

 

unit, wait 30 seconds, reconnect, and retry.

 

Adapter has failed).

4.

Remote Supervisor Adapter, if installed

 

 

5.

System board

 

 

 

 

166-201-001

System Management failed:

1. If installed, reseat I2C cable between Remote

 

(I2C Bus Error(s))

 

 

Supervisor Adapter (in PCI slot 1/J44) and system

 

 

 

 

(ISMP indicates I2C errors on

 

board

 

2.

Reseat memory DIMMs

 

bus 0. Potential FRUs:

 

 

 

 

Memory DIMMs, system

3.

Memory DIMMS

 

board)

4.

System board

 

 

 

 

 

 

166-201-002

System Management failed:

1. Reseat I2C cable between operator information panel

 

(I2C Bus Error(s))

 

 

and system board (J39)

 

 

 

 

(ISMP indicates I2C errors on

2.

Operator information panel

 

bus 2. Potential FRUs: LED

3.

System board

 

front panel, system board).

 

 

 

 

 

 

166-201-003

System Management failed:

1. Reseat cables between power backplane and system

 

(I2C Bus Error(s))

 

 

board

 

 

 

 

(ISMP indicates I2C errors on

2.

Operator information panel

 

bus 3. Potential FRUs: power

3.

System board

 

backplane, system board).

 

 

 

 

 

 

166-201-004

System Management failed:

1. If installed, reseat I2C cable between Yugo and DASD

 

(I2C Bus Error(s))

 

 

backplane and DASD I2C on system board (J0)

 

 

 

 

(ISMP indicates I2C errors on

2.

System board

 

bus 4. Potential FRUs: DASD

 

 

 

backplane, system board).

 

 

 

 

 

 

166-201-005

System Management failed:

1.

Reseat Memory DIMMs

 

(I2C Bus Error(s))

 

2.

Reseat processors

 

 

 

(ISMP indicates I2C errors on

3.

Memory DIMMs

 

bus 0, 1, or 5. Potential

4.

Processors

 

FRUs: Memory DIMMs,

 

5.

System board

 

CPUs, system board).

 

 

 

 

 

 

 

166-260-000

System Management failed:

1. Disconnect all server and option power cords from

 

(Unable to restart Remote

 

 

server, wait 30 seconds, reconnect, and retry.

 

Supervisor Adapter). Restart

 

 

2. Reseat the Remote Supervisor Adapter in PCI slot 1/J44).

 

Remote Supervisor Adapter

 

3.

Remote Supervisor Adapter

 

Error. After restarting,

 

Remote Supervisor Adapter

 

 

 

communication was lost.

 

 

 

Unplug and cold boot to reset

 

 

 

the Remote Supervisor

 

 

 

Adapter).

 

 

 

 

 

 

102NAS 200 User’s Reference

Page 114
Image 114
IBM 201 manual NAS 200 User’s Reference