Table 5. Engine troubleshooting symptoms and suggested actions (continued)

Device/Problem

Symptom

Suggested action

 

 

 

Intermittent problems

A problem occurs only

Verify that:

 

occasionally and is

1.

All cables and cords are connected securely to the rear of the

 

difficult to detect.

 

appliance and attached options.

 

 

2.

When the appliance is turned on, air is flowing from the rear

 

 

 

of the appliance at the fan grill. If there is no air flow, the fan

 

 

 

is not working. This causes the appliance to overheat and shut

 

 

 

down.

 

 

3.

Ensure that the SCSI bus and devices are configured correctly

 

 

 

and that the last external device in each SCSI chain is

 

 

 

terminated correctly.

 

 

If the items above are correct, call for service.

 

 

 

 

Keyboard, mouse, or

All or some keys on the

1.

Make sure that the keyboard cable is properly connected to

pointing-device

keyboard do not work.

 

the appliance.

problems (if

 

2.

Make sure that the appliance and the monitor are turned on.

attached).

 

3.

Try using another keyboard.

 

 

If the items above are correct, call for service.

 

 

 

 

 

The mouse or pointing

1.

Verify that the mouse or pointing-device cable is securely

 

device does not work.

 

connected and the device drivers are installed correctly.

 

 

2.

Try using another mouse or pointing device.

 

 

If the problem remains, call for service.

 

 

 

Memory problems

The amount of memory

Verify that:

 

displayed is less than

1.

The memory modules are seated properly.

 

the amount of memory

2.

You have installed the correct type of memory.

 

installed.

3.

If you changed the memory, you updated the memory

 

 

 

configuration with the Configuration/Setup Utility program.

 

 

4.

All banks of memory on the DIMMs are enabled. The

 

 

 

appliance might have automatically disabled a DIMM bank

 

 

 

when it detected a problem or a DIMM bank could have been

 

 

 

manually disabled.

 

 

If the above items are correct, run the memory diagnostic

 

 

program. The system might have detected a bad memory module

 

 

and automatically reallocated memory to enable you to continue

 

 

to operate. If the memory tests fail, call for service or replace the

 

 

failing DIMM.

 

 

 

Microprocessor

The appliance emits a

The startup (boot) microprocessor is not working properly.

problems

continuous tone during

Verify that the startup microprocessor is seated properly. If it is,

 

POST.

 

 

replace the startup microprocessor.

 

 

If the problem remains, call for service.

 

 

 

 

Chapter 7. Troubleshooting 53