IBM 201 manual Power-supply LEDS, Troubleshooting

Models: 201

1 140
Download 140 pages 39.72 Kb
Page 61
Image 61

Table 3. Power-supply LEDS

AC Good

DC Good

Description

FRU/action

LED

LED

 

 

 

 

 

 

 

 

 

 

Off

Off

No power to system

1.

Check AC power to system.

 

 

or AC problem.

 

 

2.

Power supply

 

 

 

 

 

 

 

 

 

On

Off

Standby mode or DC

1.

Check system board cable

 

 

problem.

 

 

 

connectors J32, J33, and J35.

 

 

 

 

 

 

 

 

Move jumper on J32’s extension

 

 

 

 

cable to pins 2-3 to bypass

 

 

 

 

power control. If the DC Good

 

 

 

 

LED comes on, press

 

 

 

 

Ctrl+Alt+Delete. Watch the

 

 

 

 

screen for any POST errors.

 

 

 

 

Check the System Event/Error

 

 

 

 

Log for any listed problems. If

 

 

 

 

the system powers up with no

 

 

 

 

errors:

 

 

 

 

a.

Power switch assembly

 

 

 

 

b.

System board

 

 

 

2.

Remove the adapters and

 

 

 

 

disconnect the cables and power

 

 

 

 

connectors to all internal and

 

 

 

 

external devices. Power-on the

 

 

 

 

system. If the DC Good LED

 

 

 

 

comes on, replace the adapters

 

 

 

 

and devices one at a time until

 

 

 

 

you isolate the problem.

 

 

 

3.

Power supply

 

 

 

4.

Power backplane

 

 

 

5.

System board

 

 

 

 

 

 

On

On

Power is OK.

N/A

 

 

 

 

 

 

 

 

Chapter 7. Troubleshooting 49

Page 61
Image 61
IBM 201 manual Power-supply LEDS, Troubleshooting